Series AMEL10-AZ Preliminary 10 Watt | AC-DC Converter FEATURES: • I/O Isolation 3000VAC • Operating Temp: -40oC to +80oC • Over load, Over Voltage, Short Circuit Protection • Up to 79% efficiency • • Energy Star compliant Ultra small package Models Single output Model AMEL10-3.3SAZ AMEL10-5SAZ AMEL10-12SAZ AMEL10-15SAZ AMEL10-24SAZ Input Voltage (VAC/Hz) Input Voltage (VDC) 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 90-305/47-440 120-430 120-430 120-430 120-430 120-430 Input Specifications Parameters Current Inrush current <2ms (cold start) Leakage current External fuse Input dissipation Output Specifications Parameters Voltage accuracy Line regulation Load regulation Transient recovery time Transient response deviation Ripple & Noise* Max Output wattage (W) 9.9 10 10 10 10 Output Voltage (V) 3.3 5 12 15 24 Conditions Parameters Tested I/O voltage Isolation Resistance www.aimtec.com F 052e R8 3.00 2.00 0.84 0.67 0.42 Typical 115VAC 230VAC 115VAC 230VAC 0.23 0.15 slow blow type No Load 1 <0.5 Conditions Typical 0-100% load 25% load step 20MHz bandwidth *Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) parallel capacitor. Isolation Specifications Output Current max (A) Conditions ±2 ±1 ±2 500 ±2 100 Typical 3sec >1000 Tel: +1 514 620 2722 1 of 3 Maximum capacitive load (µF) Efficiency (%) 2200 1000 680 470 470 Maximum 10 20 0.25 Maximum Rated 3000 74 76 78 79 79 Units A A A A mA A W Units % % % µs % of Vout mV p-p Units VAC MΩ Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-AZ Preliminary General Specifications Parameters Conditions 10 Watt | AC-DC Converter Typical Maximum Units Switching frequency 66 KHz Over load protection Auto recovery, Fold back 150 % Over voltage protection Zener Diode Clamp Short circuit protection Auto recovery o Operating temperature With derating above 50ºC -40 to +80 C o Maximum case temperature 100 C o Storage temperature -45 to +95 C Temperature coefficient ±0.02 % / oC Humidity Non condensing 20 ~ 95 % RH Case material Plastic resin + Fiberglass (flammability to UL 94V-0) Weight 70 g Dimensions (L x W x H) 2.22 x 1.21 x 0.99 inches 56.48 x 30.86 x 25.10mm MTBF > 400 000 hrs (MIL-HDBK -217F, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Test Shock Vibration Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation Conditions Half sine wave 5gn 30 ms before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine 1mm 3g 10-100Hz, speed 0.05Hz/s Safety Specifications Parameters Standards www.aimtec.com F 052e R8 Information technology Equipment EMI - Conducted and radiated emission Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Information Technology Equipment Information Technology Equipment Tel: +1 514 620 2722 2 of 3 EN 60950-1:2006+A11:2009 EN55011, class B IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11 UL 60950-1:2007 CAN/CSA-C22.2 No.60950-1-07 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEL10-AZ Preliminary 10 Watt | AC-DC Converter Pin Out Specifications Pin Single 1 2 3 4 5 AC Input (N) AC Input (L) +V Output -V Output No pin Dimensions 3 Top View 4 5,27 (0.21) 2 5 5.37 (0.21) 1 10.20 (0.40) 1 10.20 (0.40) 45.72 (1.80) 20.40 (0.80) 30.86 (1.21) 5.27 (0.21) 56.46 (2.22) 2 5.37 (0.21) 3 Top View 4 5 25.10 (0.99) DIV: 10.00 (0.40) 8.00 (0.31) 5Ø 1.0 (Ø 0.04) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.05 (0.04 ± 0.002) Pin Pitch Tolerance ±0.35 (±0.014) 1.05 (0.04) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R8 Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only