ETC 37795

Features
--
-
------------------
----------L
-
SPECIFICATIONS
Properties
Electrostatic Decay
Surface Resistance
Surface Resistance, Low R.H. Cut-off
High-Voltage Discharge Resistance
Static Shielding
Charged Device Model (CDM) Safety
Current-Carrying Hazard
Corrosivity
Antistat Transfer
Water & Isopropyl Alcohol Extraction
Tests for Antistat Permanence
Sloughing Test
Shelf Life
--
---
D
--
---
Recyclability
Biodegradability
Volume Conductivity
RoHS Compliance Statement
None of the following materials are
intentionally added in manufacturing
this product: lead, mercury, cadmium,
hexavalent chromium, polybrominated
biphenyls (PBB) or polybrominated
diphenyl ethers (PBDE) as outlined in
the Directive 2002/95/EC Article 4.1.
See Protektive Pak Inc. letter on-line at
ProtektivePak.com.
-
--
W
• Economical and efficient way to store and transport DIP Tubes
and Rails
• Each cell has an extender tab which may be labeled to identify
the contents
• Tube Handler may be rotated on shelves to view the extender
tab either vertically or horizontally
• Cell identification labels included
• Shipped knocked-down; easy to assemble
• Made in America
Made in America
Typical Values
0.01 seconds at 72°F and 11.8% R.H.
10E6 - 10E8 ohms/sq. after 11 days at 68°F and 12% R.H. for surface. 10E3 - 10E4
ohms/sq. for buried shielding layer
4% R.H.
Failure rate 0/5 (no oxide damage in five consecutive tests)
99.9% attenuation at 10kV; 99.6% attenuation at 30kV
RTG >10E7 ohms at 86% R.H. or less
10E3 mA at 110V; 10E3 mA at 220V
Contains 1-3 ppm reducible sulfur
No transfer
Surface resistance 10E8 - 10E9 ohms/square at 74°F
and 36% R.H.
Negligible surface damage at 10 cycles and <5% of surface damage at 200
cycles in Taber Abrasion Test. No conductive particles abrased from surface
Complete recyclability of package
Biodegradation in or on moist soil
Conductivity from wall to wall as well as across surface to assure permanence
of the antistatic property
Indefinite
Test Procedures/Method
FED-STD-101, Method 4046
ASTM D257
Rockwell International Test Report of December 20, 1991
Rockwell International Test Report of December 20, 1991
EIA 541, appendix E, capacitive probe test
Rockwell International Test Report of December 20, 1991
ESD from A to Z
FED-STD-101, Method 3005 for reducible sulfur
Rockwell International Test Report of January 8, 1992
Rockwell International Test Report of January 8, 1992
ASTM D4060 at 70 rpm with CS-17 abrasive-coated wheels and
1000 grams load
Rockwell International Test Report of January 8, 1992
Rockwell International Test Report of January 8, 1992
Rockwell International Test Report of January 8, 1992
TUBE HANDLERS
PROTEKTIVE PAK
13520 MONTE VISTA AVENUE, CHINO, CA 91710
PHONE (909) 627-2578, FAX (909) 363-7331
ProtektivePak.com
© 2007 DESCO INDUSTRIES INC.
Employee Owned
See reverse side
for available sizes.
DRAWING NUMBER
37790
DATE:
September
2007
Item No.
© 2007 DESCO INDUSTRIES INC.
Employee Owned
O.D.
LxWxD
Cell I.D.
LxWxD
# of Cells
37790
12 x 6 x 20
1-7/8 x 1-7/8 x 20
10
37791
12 x 6 x 24
1-7/8 x 1-7/8 x 24
10
37792
12 x 12 x 20
1-7/8 x 1-7/8 x 20
25
37793
12 x 12 x 24
1-7/8 x 1-7/8 x 24
25
37794
24 x 12 x 20
1-7/8 x 1-7/8 x 20
50
37795
24 x 12 x 24
1-7/8 x 1-7/8 x 24
50