ETC 44053

Protection
Reference
44049
44050
44051
44052
44053
44054
44055
44056
44057
44058
44059
44060*
PRIMARY VOLTAGE
Secondary Secondary No-load
voltage
Current
voltage
V
mA
V
6
167
8,6
9
111
12,9
12
83
17,2
15
67
21,6
18
56
25,9
24
42
37,9
2x6
2 x 83
2 x 8,6
2x9
2 x 56
2 x 12,9
2 x 12
2 x 42
2 x 19
2 x 15
2 x 33
2 x 23,6
2 x 18
2 x 28
2 x 24,9
2 x 24
2 x 21
2 x 37,9
Ambient
Temperature
°C
T 70 B
T 70 B
T 70 B
T 70 B
T 70 B
T 70 B
T 70 B
T 70 B
T 70 B
T 70 B
T 70 B
T 70 B
Rating
VA
1
1
1
1
1
1
1
1
1
1
1
1
* to be noted : 2 x 24 V non safety transformer approved,
conform to EN 61558-2-6 (Isolating transformer).
l
l
l
l
l
l
Vacuum filling
Two compartments bobbins
Self-extinguishing plastics UL 94
VO
Degree of protection IP 00
70 grams weight
Resin class B CEI 85 (20 000 h
testing to CEI 126)
l
l
l
l
l
Inherently short-circuits proof
transformer
30 V and 36 V models are VDE
EN 61558-2-6 certified (production
on request)
Insulation voltage 4 KV (6 KV
MYRRA test)
100% tested production
Certification : CCA procedure on
request
n