PHIHONG PSA120U-240V

WWW.PHIHONG.COM
120 Watt Universal 3-Wire Input Adapter
PSA120U-V Adapter Series meets EISA and Ecodesign Requirements
Features
 EISA Compliant
 Compliant with Ecodesign ErP Directive
2009/125/EC level 2 annex 1b



Non-vented/Spill-proof Case
Level V Efficiency Compliant
Class B EMI
Applications
 Networking
 Peripherals


Industrial
Test and Measurement
Safety Approvals
 cUL/UL

CE
Mechanical Characteristics
 Length: 174mm (6.85in)
 Width: 77mm (3.03in)
Output Specifications


Height: 43mm (1.69in)
Weight: 0.8Kg (1.76lbs)
1
2
Model
DC Output Voltage
PSA120U-120V
PSA120U-240V
PSA120U-480V
PSA120U-560V
12V
24V
48V
56V
Load
Min.1
0A
0A
0A
0A
Max.
10A
5.0A
2.5A
2.14A
Efficiency
Level2
Dynamic load from 0.1A to full load.
See more detail on the second page
Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for the
most up-to-date specifications and contact information.
Revised 11/21/2011
WWW.PHIHONG.COM
PSA120U-V Characteristics
Input:
AC Input Voltage Rating
100 to 240VAC
AC Input Voltage Range
90 to 264VAC
AC Input Frequency
47 to 63Hz
Input Current
2.5A at 100VAC
1.5A at 240VAC
Leakage Current
3.5mA maximum at 254VAC and 50Hz
Inrush Current
65A at 120VAC
130A at 240VAC
(Cold Start at ambient 25°C)
Input Power Saving
<0.5W at no load
OUTPUT:
Efficiency Level
Level V Compliant
87-90% minimum average efficiency
Regulation (Line & Load)
±5%
Short-Circuit Protection
Output will withstand a short circuit across the outputs
with auto-restart function. Output can be shorted without
damage.
ENVIRONMENTAL
Temperature
Operation
0 to +40°C
Non-operation
-20 to +70°C
Humidity
20 to 80%
Emissions
FCC Class B
EN55022 Class B
CISPR22 Class B
Immunity
ESD
RS
EFT
Surge
CS
Voltage Dips
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-11
Dielectric Withstand (Hi-Pot) Test
Primary to Secondary: 3000V AC for 1 min., 10mA
Over-Voltage Protection
Output is protected from over voltage fault at all
conditions including open-loop
MTBF
≥100K Hours when operated at 75% continuous load and
ambient 25°C
Over-Power Protection
Auto-Reset
DC Output Connector (12V model)
Molex P/N: 39-00-0059
Connecting Molex P/N: 39-01-3065
Pin 1: +12V
Pin
Connections:
Pin 2: +12V
Pin 3: +12V
Pin 4: GND
Pin 5: GND
Pin 6: GND
Ripple (P-P Max)
12V
150mV
24V
240mV
48V
480mV
56V
560mV
(Measured using 12-inch twisted pair terminated
with a 10uF capacitor and 0.1uF ceramic in
parallel)
DC Output Connector (24V, 48V and 56V models)
2.5 x 5.5mm Center Positive Barrel Standard
Input Connector
3-Wire IEC320-C14
PSA120U-V Characteristics
PSA120U-120-R
PSA120U-240-R, PSA120U-480-R, PSA120U-560-R
WWW.PHIHONG.COM