METRAport3A Folding Analog Multimeter 3-349-302-03 1/4.04 • 9 voltage measuring ranges, V : 100 mV, 300 mV, 1 V, 3 V, 10 V, 30 V, 100 V, 300 V and 600 V • 7 current measuring ranges, A : 10 µA, 100 µA, 1mA, 10 mA, 100 mA, 1A and 10 A • 5 resistance measuring ranges: 1 Ω ... 2 kΩ/ 10 Ω ... 20 kΩ/ 100 Ω ... 200 kΩ/ 1 kΩ ... 2 MΩ/ 10 kΩ ... 20 MΩ • 9 level measuring ranges: -40 dB ... +62 dB • High input resistance of 10 MΩ for no-load voltage measurement • Reflective scale in folding lid which can be tilted for easy reading and provides transport protection as well, accuracy class 1.5 = • Overload protection: 600 V in all functions and range settings • Automatic battery shutdown when instrument is folded closed Applications The multimeter is equipped with an indicator display and an electronic amplifier. It can be used in a wide variety of practical electronics applications, for example in R&D, manufacturing, equipment operation, in the test lab and for service calls, as well as for training and vocational education. Description The multimeter has 46 measuring ranges for direct and alternating voltages of up to 600 V, alternating voltage levels from -40 to +62 dB, direct and alternating current of up to 10 A and resistances of up to 20 MΩ. It has a constant input resistance of 10 MΩ in all voltage measuring ranges. The multimeter is calibrated in RMS values for periodic sinusoidal quantities. It makes use of full-wave rectification for the evaluation of the arithmetic mean value. All measuring ranges can be selected with the central measuring range selector switch. The ranges are laid out in a clear-cut fashion around the selector switch. The measuring device and the display unit are enclosed in two separate housing components which are connected to each other by means of a hinge which can be snapped into various positions. In this way, the ideal angle for ease of reading can be selected with the instrument in any position. GOSSEN METRAWATT GMBH 300 V CAT III 600 V CAT II IEC/EN 61010-1, second edition Several well coordinated safety devices protect the instrument against damage caused by incorrect operation and overloading within the specified overload limit values: • Oversized precision resistors • Fuse link in combination with protective rectifier diodes • Overvoltage arrester / positive temperature coefficient resistors (PTCs) The instrument can be operated independent of mains current with a commercially available 9 V flat cell battery. Long battery service life is assured thanks to the minimal current consumption of the instrument’s electronic components. The multimeter’s rugged design provides for outstanding protection where harsh mechanical stressing prevails. When folded together, the instrument is provided with extra mechanical protection for the measuring device, as well as for the display unit. The connector jacks are protected against accidental contact. Suitable measurement cables with 4 mm test probes are included as standard equipment. Applicable Regulations and Standards IEC/EN 61010-1:2001 VDE 0411-1:2002 Safety requirements for electrical equipment for measurement, control and laboratory use DIN EN 61326 VDE 0843, part 20 Electrical equipment for control technology and laboratory use – EMC requirements DIN EN 60529 DIN VDE 0470, part 1 Test instruments and test procedures – Degrees of protection provided by enclosures (IP code) METRAport3A Folding Analog Multimeter Characteristic Values Reference Conditions Level 2) Voltage 1) 100 mV 300 mV 1 V 3 V 10 V 30 V 100 V 300 V 600 V Constant Measuring Span -20 -10 0 +10 +20 +30 +40 +50 +60 -40 ... ÷ 1 8 -30 ... ÷ 8 -20 ... + 2 -10 ... + 12 0 ... + 22 +10 ... + 32 +20 ... + 42 +30 ... + 52 +40 ... + 62 dB dB dB dB dB dB dB dB dB Input Resistance Ri dB dB dB dB dB dB dB dB dB 10 MΩ / / 50 pF Overload Protection to 3) 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V 600 V Ambient temperature Relative humidity Normal position of use Measured quantity frequency Measured quantity waveshape Battery voltage Other influencing quantities +23° C ±2 K 40 ... 60% Instrument and scale horizontal ±1° 45 ... 65 Hz Sine 7.5 V ±0.1 V per IEC 60051/EN 60051 1) The 100 mV to 10 V measuring ranges can also be used for current measurement in accordance with the following table (e.g. reverse current or insulation current). These measuring ranges are rated at accuracy class 5. Frequency range at : 15 ... 100 Hz. Same overload protection as for voltage measuring ranges. 2) Measured value = displayed value + constant, 0 dB 0.775 V, i.e. 1 mW at 600 Ω 3) Protected with PTC resistor ~ Range 100 mV 300 mV 1 V 3 V 10 V 30 V Current at Upper Range Limit 10 nA 30 nA 100 nA 300 nA 1 µA 3 µA Input Resistance Ri 10.0 kΩ 1.0 kΩ 100.0 Ω 10.0 Ω 1.4 Ω 480 mΩ 26 mΩ Current 10 100 1 10 100 1 10 µA µA mA mA mA A A Resistance Range Ω Ω Ω kΩ kΩ x 1 x 10 x 100 x 1 x 10 Reading Range 1 10 100 1 10 Ω ... 2 kΩ Ω ... 20 kΩ Ω ... 200 kΩ kΩ ... 2 MΩ kΩ ... 20 MΩ Ri 10 MΩ Temperature +5 ... +23 ... +35° C Limiting temperatures For accuracy +5 ... +35° C For operation 0 ... +40° C For storage -25 ... +65° C (without batteries) Position Additional influence error of max. ±1% of the scale length if the scale is tilted between 0 and ±120° relative to horizontal Frequency Additional influence error of max. ±5% of full scale value in the following ranges: 100 mV, 3 V ... 10 µA ... 300 mV, Voltage Drop ∆U 100 mV 100 mV 100 mV 100 mV 140 mV 0.480 V 260 mV Value at Scale Middle (Ri) 45.6 Ω 456.0Ω 4.56 kΩ 45.6 kΩ 456.0kΩ OpenCircuit Voltage U0 100mV 100mV 100mV 1 V 1 V Overload Protection to 600 V 3) 600 V 3) 600 V 3) 600 V 3) 600 V 3) 600 V 3) 600 V 4) ShortCircuit Current IK 2.2 mA 0.22mA 22 µA 22 µA 2.2 µA Overload Protection to 600 V 3) 600 V 3) 600 V 3) 600 V 3) 600 V 3) 3) Protection by means of FF 1.6A/600V AC fuse link in combination with rectifier diodes. 4) FF 16A/600V fuse link, 10 A: max. 10 minutes Accuracy under Reference Conditions per IEC 60051/EN 60051 Class 1.5 for zero-frequency quantities, class 2.5 for periodic sinusoidal quantities and class 1.5 for resistance (intrinsic error relative to 69 mm scale length) corresponding to max. 10% intrinsic error of the measured value within the range of the exaggerated scale arc. 2 Influencing Quantities and Nominal Ranges of Use 600 V: 10 A: 1 V: 15 Hz ... 1 kHz 15 Hz ... 1 kHz 15 Hz ... 200 Hz Auxiliary voltage No additional influence error. The upper limit must be set with the potentiometer for all measuring ranges in the case of resistance measurement. Series-mode interference voltage damping For V : > 60 dB, AC 50 Hz For V~: > 120 dB, DC Common-mode interference voltage damping > 120 dB, DC and 50 Hz AC Other influencing quantities per IEC 60051/EN 60051 Power Supply Battery operation Battery service life Battery test Nominal voltage: 9 V , 9 V flat cell battery per IEC 6LR61 (6F22), alkaline manganese, zinc-carbon or NiCd rechargeable battery. With zinc-carbon: approx. 500 hours, with alkaline manganese: approx. 1000 hours, with NiCd: approx. 200 hours, in the Ω x 1 range: ¼ of specified service life Pointer must be within the battery test field. GOSSEN METRAWATT GMBH METRAport3A Folding Analog Multimeter Fuses Ranges to 1 A and Ω 10 A range Order Information FF 1.6A/600V, 6 mm x 32 mm in combination with rectifier diodes for the 10 µA ... 1 A and Ω x1 ... kΩ x10 ranges, switching capacity: 50 kA at 600 V~ FF 16A/600V AC, 6 mm x 32 mm, switching capacity: 50 kA at 600 V~ Measuring category Operating voltage Fouling factor Test voltage Type Article Number Folding analog multimeter for demanding requirements METRAport3A M113A Consumable Materials Fuse link (shipped in package of 10) FF(UR)1.6A/700V AC Z109E Fuse link (shipped in package of 10) FF(UR)16A/600V AC Z109A Accessories Electrical Safety Safety class Description Carrying pouch II per IEC/EN 61010-1:2001/VDE 04111:2002 II III 600 V 300 V 2 3.5 kV~ per IEC/EN 61010-1:2001/ VDE 0411-1:2002 Electromagnetic Compatibility (EMC) Interference emission EN 61326:2002 class B Interference immunity EN 61326:2002 IEC 61000-4-2:1995/A1:1998, Feature B 8 kV atmospheric discharge 4 kV contact discharge IEC 61000-4-3:1995/A1:1998, Feature B 3 V/m F822 GTY 3172 095 P01 Current measuring adapter for safe, trouble-free measurement of current consumption via the mains plug of connected power consumers SM16 GTM 9070190E0002 High-voltage probe, 3 kV/3 V, , also suitable as low pass filter for frequency converter signals GTZ 3431 001R0011 HV3 High-voltage probe, 30 kV / 30 V DC, For safe measurement of direct voltage of up to 30 kV HV30 GTZ 3431 001R0001 Temperature probes with integrated or plug-on sensors (see Measuring Instruments and Testers catalog) Z3431... GTZ 3431... For additional information regarding accessories please see: • Measuring Instruments and Testers catalog • www.gossenmetrawatt.com Accessories SM16 Current Measuring Adapter Mechanical Design Protection Dimensions Weight Housing: IP 40, connector jacks: IP 20 146 x 118 x 44 mm (folded closed) approx. 0.45 kg without battery HV3 High-Voltage Probe Standard Equipment 1 1 1 1 multimeter 9 V battery KS17 measurement cable set operating instructions HV30 High-Voltage Probe GOSSEN METRAWATT GMBH 3 METRAport3A Folding Analog Multimeter Current Measuring Accessories Suitable for METRAport All current sensors and transformers are equipped with a connector cable (1.2 to 1.5 m long) with 4 mm safety banana plugs Type Designation Measuring Range Max. Transformation Meas. Category Wire Dia. Ratio Frequency Range Intrinsic Error ±(% rdg. + ...) Article Number 3A AC/DC Current Sensors with Voltage Output Z201A Clip-on current sensor with battery mode (30 h) 0.01 ... 20 A~/30 A– 300 V / CAT III 19 mm 100 mV/A DC ... 400 Hz 1% + 0.002 A ... 20 kHz Z201A ● Z202A Clip-on current sensor with 2 measuring ranges, battery mode (50 h) 0.1 ... 20 A~/30 A–, 1 ... 200 A~/300 A– 300 V / CAT III 19 mm 10 mV/A, 1 mV/A DC ... 2 kHz ... 10 kHz Z202A ● Z203A Clip-on current sensor with 2 measuring ranges, battery mode (50 h) 1 ... 200 A~/300 A–, 1 ... 1000 A~/A– 300 V / CAT III 31 mm 1 mV/A DC ...10 kHz 1% +0.5 A Z203A ● Z13B Clip-on current sensor with 2 measuring ranges, battery mode (50 h) 0,2 ... 40 A~/60 A–, 300 V / 0.5 ... 400 A~/600 A–, CAT IV 50 mm 10 mV/A, 1 mV/A DC ... 65 Hz 1.5% + 0.5 A ... 10 kHz 2.5% Z13B ● 1% + 0.03 A, 1% + 0.3 A AC Current Sensors with Voltage Output WZ12B Clip-on current sensor 10 mA~ ... 100 A~ 300 V / CAT III 15 mm 0.1 mV/mA 45 ... 65 ... 500 Hz 1.5% +0.1 mA Z219B ● WZ12C Clip-on current sensor with 2 measuring ranges 1 mA~ ... 15 A~, 1 ... 150 A~ 300 V / CAT III 15 mm 1 mV/mA, 1 mV/A 45 ... 65 ... 400 Hz 3% + 0.15 mA, 2% + 0.1 A Z219C ● WZ11B Clip-on current sensor with 2 measuring ranges 0.5 ... 20 A~, 5 ... 200 A~ 600 V / CAT III 20 mm 100 mV/A, 10 mV/A 30 .. .48 ... 1 ... 3% 65 ... 500 Hz Z208B ● Z3512A Clip-on current sensor with 4 measuring ranges 1 mA ... 1/10 A~ 100/1000 A~ 600 V / CAT III 52 mm 1 V/A, 100 mV/A, 10 ... 48 ... 10 mV/A, 1 mV/A 65 ... 3 kHz Z225A ● AF033A AmpFLEX flexible current sensor with 2 measuring ranges, battery (150 h) 5 ... 30 A~, 5 ... 300 A~ 1000 V / Length 100 mV/A, CAT III 600 mm 10 mV/A 10 ...100 Hz 1% + 0.5 A, ... 20 kHz 1% +0.5 A Z207A ● AF11A AmpFLEX flexible current sensor, battery (150 h) 5 ... 1000 A~ 1000 V / Length 1 mV/A CAT III 450 mm 10 ...100 Hz 1% + 2 A ... 20 kHz Z207D ● AF33A AmpFLEX flexible current sensor with 2 measuring ranges, battery (150 h) 5 ... 300 A~, 5 ... 3000 A~ 1000 V / Length 10 mV/A, CAT III 900 mm 1 mV/A 10 ...100 Hz 1% + 0.5 A, ... 20 kHz 1% + 2 A Z207B ● AF101A AmpFLEX flexible current sensor with 2 measuring ranges, battery (150 h) 5 A~... 1 k A~, 50 A~... 10 k A~ 1000 V / Length 1 mV/A, CAT III 1200 mm 0.1 mV/A 10 ...100 Hz 1% + 2 A, ... 20 kHz 1% + 10 A Z207C ● 0.5 ... 3%, 0.2 ... 1% AC Current Transformer with Current Output WZ12A Clip-on current transformer 15 ... 180 A~ 300 V / CAT III 15 mm 1 mA/A 45 ... 65 ... 400 Hz 3% Z219A ● WZ12D Clip-on current transformer 30 mA ... 150 A~ 300 V / CAT III 15 mm 1 mA/A 45 ... 65 ... 500 Hz 2.5% +0.1 mA Z219D ● WZ11A Clip-on current transformer 1 ... 200 A~ 600 V / CAT III 20 mm 1 mA/A 48 ... 65 ... 400 Hz 1 ... 3% Z208A ● Z3511 Clip-on current transformer 4 ... 500 A~ 600 V / CAT III 30 x 63 mm 1 mA/A 48 ... 65 ... 1 kHz 3% +0.4 A GTZ 3511 000 R0001 ● Z3512 Clip-on current transformer 0.5 ... 1000 A~ 600 V / CAT III 52 mm 1 mA/A 30 .. .48 ... 65 ... 5 kHz 0.5% ... 0.7% GTZ 3512 000 R0001 ■ Z3514 Clip-on current transformer 1 ... 2000 A ~ 600 V / CAT III 64 x 150 1 mA/A mm 30 .. .48 ... 65 ... 5 kHz 0.5% +0.1 A GTZ 3514 000 R0001 ■ ● Without restriction ■ As of 50 A WZ11/12 ... Z201 ... Z203 Edited in Germany • Subject to change without notice • PDF version available on the Internet GOSSEN METRAWATT GMBH Thomas-Mann-Str. 16 - 20 90471 Nürnberg, Germany Phone: +49-(0)-911-8602-0 Fax: +49-(0)-911-8602-669 E-mail: [email protected] www.gossenmetrawatt.com Z13B