ETC CA1884

C.A 1884
C.A 1886
C.A 1888
For maintenance and building inspections,
RayCAm sees everything!
High-Resolution
Infrared Cameras
ages to
om real im
Fr
Certification granted on the basis of a single test
Available at www.cnpp.com
N° 2008-0012 - N° 2010-0020 -N° 2010-0021
lT
horough analysis with comprehensive
parameterization
l Large screen for easier reading
l Temperature up to 600 °C
l Matrix up to 384 x 288
nEW
nEW
nEW
ages
infrared im
ADVANTAGES
The RayCAms’ design and the technologies used to manufacture them provide a wide
range of advantages. Their ergonomic design means comfortable measurement even
in places where access is difficult:
● IP 54 leakproofing
● excellent legibility thanks to its multidirectional screen,
even in places where access is difficult
● comfortable handling due to its pistol shape
Performance:
● automatic detection of hottest/coldest point
● parameter settings affecting measurement:
• adjustable emissivity
• adjustment of measurement distance
• parameters for defining relative humidity and ambient temperature
● parameterizable alarms
● isotherm function
● storage capacity of 1,000 radiometric images organized in 250 folders
and back-up on SD card with the C.A 1886 and C.A 1888
With the new RayCAms, users can choose the mode for viewing the target: infrared, real or a mix of both
with the «MixVision» function. This allows you to adjust the transparency (in %) of the infrared image in
relation to the real image, thus helping to identify problem areas immediately.
Lens Specifications
The C.A 1884 & C.A 1886 are delivered with a 20° x 15° lens. The C.A 1888 is equipped with a 24° x 18° lens.
20° x 15° 2.2 mrad 10 cm HFOV (m)
0.1 m
0.3 m 0.5 m 1 m
2 m
6 m
10 m
30 m
0.03
0.10
0.70
2.11
3.52
10.57
0.17
0.35
100 m
35.26
VFOV (m)
0.02
0.07
0.13
0.26
0.52
1.57
2.63
7.89
26.33
IFOV (mm)
0.22
0.66
1.10
2.20
4.40
13.22
22.04
66.12
220.40
PPOM (mm)
13.20
39.66
66.12 198.36
661.20
24° x 18° 1.3 mrad 10 cm HFOV (m)
0.66
1.98
3.30
6.60
0.05
0.15
0.25
0.5
1
5.99
4.99
3.74
14.98
11.23
49.92
VFOV (m)
0.04
0.11
0.19
0.37
0.75
4.49
IFOV (mm)
0.13
0.39
0.65
1.3
2.6
7.8
13
39
130
37.44
PPOM (mm)
0.39
1.17
1.95
3.9
7.8 23.4
39
117
390
• HFOV and VFOV represent the horizontal and vertical fields of view, respectively.
• IFOV corresponds to the camera’s spatial resolution, i.e. what a detector sees. The IFOV of the C.A 1884 is 2.2 mRad, meaning that, at a distance of 1 m, the detector observes an area of 2.2 mm.
• SMO (Smallest Measurable Object): to ensure correct measurement, the target observed must cover at least three detectors, i.e. SMO = 3 IFOV.
ELECTRICAL APPLICATIONS
Circuit-breaker / Generator
• detection of damaged fuses
and bad connections
• verification of correct heat diffusion
in the generator
MECHANICAL APPLICATIONS
Electric motors
• detection of internal component anomalies
or malfunctions to prevent motor
overheating
THERMAL APPLICATIONS
Water leaks / energy losses
• energy consumption monitoring /
building inspections
• location of losses (heating, insulation, etc.)
Infrared Image / Real Image /
With the RayCAm Report software, you can combine your thermogram with a real image.
This allows you to identify the fault or dysfunction so that you can make the appropriate
corrections!
The MixVision function is available on the C.A 1886 and C.A 1888 models. Users can
reinitialize the merge function by modifying the IR / real percentage to suit your requirements
and ensure clearly-interpretable reports: this percentage can be adjusted from 0 to 100 % !
Analysis mode
This new mode is available on the C.A 1886 and C.A 1888. It can be used to open one or
more images, add various analytical tools and obtain a summarized presentation of all the
results in a table. This mode is useful for first-level analysis when you simply want a rough idea
of the temperature values without saving the analyses.
Genuine, accurate analysis
If a characteristic on the radiometric image is changed, the other values are
automatically recalculated.
RayCAm Report allows you to define the emissivity of each point in the thermogram,
an essential feature when the thermogram contains different materials.
Choose a different configuration for
each analytical tool inserted on your
thermogram.
A wide range of possibilities:
● specify a different emissivity
from that of the thermogram as a whole
● display a value label next to the tool
● display the Max/Min temperature
within an area of analysis
Delivered with the RayCAm Report software
RayCAm Report is the ideal tool for analysing the results and creating customized reports.
Its interface is so simple that anyone can learn to use it very quickly.
All the analysis functions are accessible via the toolbar. Depending on their requirements,
users can position various elements:
● cursors (automatic display of the temperature at the point selected)
● thermal profile (automatic display of the Min/Max/Average temperatures of the line)
● a square or circle for area analysis (ideal for Min/Max/Average temperature
comparisons between terminals, for example)
● Result tables quickly display all the data / analytical tools on the thermogram automatically
● The «Max» function automatically indicates the hottest point in the whole thermogram
or in a predefined area of analysis.
There are now also new functions available with the C.A 1886 and C.A 1888:
● Polygons and polylines for more precise analysis of certain areas in the thermogram
● A barchart for studying the temperature distribution according to several intervals
Detector
Type
Frequency
Sensitivity (NETD)
Standard temp. range
Temp. range with option
Accuracy
IR image
Field of view
Spatial resolution
Min. focusing distance
Focusing
Real image
Min. focusing distance
IR-Merge
Image size
Emissivity correction
Parameter settings
Measurement tools
Comments
Storage
Storage type
Screen
Battery
Battery recharging
Protection
C.A 1884
C.A 1886
C.A 1888
Detector Specifications
160 x 120
384 x 288
UFPA microbolometer, 8-14 microns
50 Hz
0.1 °C to 30 °C
0.1 °C to 30 °C
0.08 °C to 30 °C
Temperature Measurements
-20 °C to +250 °C
-20 °C to +600 °C
1,500 °C
±(2 °C + 2 %)
image performance
20° x 15°
2.2 mrad
24° x 18°
1.3 mrad
10 cm
Manual
No
-
Yes
10 cm
Complete IR-Merge functions
IR image in real image from 0 to 100 %
640 x 480 pixels
Other Functions
Yes
Ambient temperature in °C, distance, humidity
3 manual cursors + 1 auto Max/Min detection, adjustable,
isotherm, high/low alarm
Voice annotations (option)
1,000 (radiometric format) + 250 folders
Internal
2 GB mini-SD Card
2.5 inches, multidirectional
3.5 inches, multidirectional
General
Battery life: 2.5 hrs
Battery life: 3 hrs
(continuous use)
(continuous use)
External battery charger
IP 54
A wide range of
accessories for
measurements
in optimum
conditions:
● USB cable for data transfer onto
a PC
● Video cable for display on external
screen
● RayCAm Report software for
processing the data
This set of accessories is supplied
as standard with your RayCAm in a
hard case.
● Operation on internal batteries or
mains adapter*
● Bluetooth accessories
● Sun-shade* to make the screen
easy to read even in bright lighting
● Tripod adapter* for hands-free
use and operation in a fixed
position
*Accessories available as an option
Standard state at delivery:
C.A 1884: delivered in a case with 1 battery charger, 1 battery, 1 USB cable,
1 video cable, RayCAm Report software and a measurement report.
C.A 1886 or C.A 1888: delivered in a case with 1 battery charger, 2 batteries,
a 2 GB mini-SD Card, 1 SD card reader, 1 video cable, RayCAm Report software and
a measurement report.
References to order:
Accessories and
replacement parts
CA 1884 ................................................ P01651228
CA 1884 high temperature 600 °C............ P01651240
CA 1884 high temperature 1000 °C.......... P01651241
CA 1884 high temperature 1500 °C.......... P01651242
CA 1884 wide-angle lens 38°.................... P01651243
CA 1884 wide-angle lens 38°
and standard lens 20°............................... P01651244
CA 1884 telephoto lens 6.4°..................... P01651245
CA 1884 telephoto lens 6.4°
and standard lens 20°............................... P01651246
CA 1886................................................. P01651260
C.A 1886 high temperature 1000 °C......... P01651261
C.A 1886 high temperature 1500 °C......... P01651262
CA 1888................................................. P01651270
C.A 1888 high temperature 1000 °C......... P01651271
C.A 1888 high temperature 1500 °C......... P01651272
CA 1886 Bluetooth................................... P01651263
CA 1888 Bluetooth................................... P01651273
Photo tripod adapter................................... P01651526
Lens cap.................................................... P01651522
USB cable.................................................. P01295274
RayCAm Report.......................................... P01651524
Battery...................................................... P01296041
Battery charger.......................................... P01296043
Mains power supply.................................... P01651527
In-vehicle battery charger
(cigarette lighter)..............................................HX0061
Thermography training ........................Please contact us
FRANCE
Chauvin Arnoux
190, rue Championnet
75876 PARIS Cedex 18
Tel: +33 1 44 85 44 86
Fax: +33 1 46 27 95 59
[email protected]
www.chauvin-arnoux.fr
united kingdom
Chauvin Arnoux Ltd
Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk
Dewsbury, West Yorkshire - WF12 7TH
Tel: +44 1924 460 494
Fax: +44 1924 455 328
[email protected]
www.chauvin-arnoux.com
middle east
Chauvin Arnoux Middle East
P.O. BOX 60-154
1241 2020 JAL EL DIB (Beirut) - LEBANON
Tel: +961 1 890 425
Fax: +961 1 890 424
[email protected]
www.chauvin-arnoux.com
For assistance and ordering
906211220 - Ed. 3 - VS 10/2010 - Non contractual document. Confirm specifications before ordering.
TECHNICAL SPECIFICATIONS