C.A 1884 C.A 1886 C.A 1888 For maintenance and building inspections, RayCAm sees everything! High-Resolution Infrared Cameras ages to om real im Fr Certification granted on the basis of a single test Available at www.cnpp.com N° 2008-0012 - N° 2010-0020 -N° 2010-0021 lT horough analysis with comprehensive parameterization l Large screen for easier reading l Temperature up to 600 °C l Matrix up to 384 x 288 nEW nEW nEW ages infrared im ADVANTAGES The RayCAms’ design and the technologies used to manufacture them provide a wide range of advantages. Their ergonomic design means comfortable measurement even in places where access is difficult: ● IP 54 leakproofing ● excellent legibility thanks to its multidirectional screen, even in places where access is difficult ● comfortable handling due to its pistol shape Performance: ● automatic detection of hottest/coldest point ● parameter settings affecting measurement: • adjustable emissivity • adjustment of measurement distance • parameters for defining relative humidity and ambient temperature ● parameterizable alarms ● isotherm function ● storage capacity of 1,000 radiometric images organized in 250 folders and back-up on SD card with the C.A 1886 and C.A 1888 With the new RayCAms, users can choose the mode for viewing the target: infrared, real or a mix of both with the «MixVision» function. This allows you to adjust the transparency (in %) of the infrared image in relation to the real image, thus helping to identify problem areas immediately. Lens Specifications The C.A 1884 & C.A 1886 are delivered with a 20° x 15° lens. The C.A 1888 is equipped with a 24° x 18° lens. 20° x 15° 2.2 mrad 10 cm HFOV (m) 0.1 m 0.3 m 0.5 m 1 m 2 m 6 m 10 m 30 m 0.03 0.10 0.70 2.11 3.52 10.57 0.17 0.35 100 m 35.26 VFOV (m) 0.02 0.07 0.13 0.26 0.52 1.57 2.63 7.89 26.33 IFOV (mm) 0.22 0.66 1.10 2.20 4.40 13.22 22.04 66.12 220.40 PPOM (mm) 13.20 39.66 66.12 198.36 661.20 24° x 18° 1.3 mrad 10 cm HFOV (m) 0.66 1.98 3.30 6.60 0.05 0.15 0.25 0.5 1 5.99 4.99 3.74 14.98 11.23 49.92 VFOV (m) 0.04 0.11 0.19 0.37 0.75 4.49 IFOV (mm) 0.13 0.39 0.65 1.3 2.6 7.8 13 39 130 37.44 PPOM (mm) 0.39 1.17 1.95 3.9 7.8 23.4 39 117 390 • HFOV and VFOV represent the horizontal and vertical fields of view, respectively. • IFOV corresponds to the camera’s spatial resolution, i.e. what a detector sees. The IFOV of the C.A 1884 is 2.2 mRad, meaning that, at a distance of 1 m, the detector observes an area of 2.2 mm. • SMO (Smallest Measurable Object): to ensure correct measurement, the target observed must cover at least three detectors, i.e. SMO = 3 IFOV. ELECTRICAL APPLICATIONS Circuit-breaker / Generator • detection of damaged fuses and bad connections • verification of correct heat diffusion in the generator MECHANICAL APPLICATIONS Electric motors • detection of internal component anomalies or malfunctions to prevent motor overheating THERMAL APPLICATIONS Water leaks / energy losses • energy consumption monitoring / building inspections • location of losses (heating, insulation, etc.) Infrared Image / Real Image / With the RayCAm Report software, you can combine your thermogram with a real image. This allows you to identify the fault or dysfunction so that you can make the appropriate corrections! The MixVision function is available on the C.A 1886 and C.A 1888 models. Users can reinitialize the merge function by modifying the IR / real percentage to suit your requirements and ensure clearly-interpretable reports: this percentage can be adjusted from 0 to 100 % ! Analysis mode This new mode is available on the C.A 1886 and C.A 1888. It can be used to open one or more images, add various analytical tools and obtain a summarized presentation of all the results in a table. This mode is useful for first-level analysis when you simply want a rough idea of the temperature values without saving the analyses. Genuine, accurate analysis If a characteristic on the radiometric image is changed, the other values are automatically recalculated. RayCAm Report allows you to define the emissivity of each point in the thermogram, an essential feature when the thermogram contains different materials. Choose a different configuration for each analytical tool inserted on your thermogram. A wide range of possibilities: ● specify a different emissivity from that of the thermogram as a whole ● display a value label next to the tool ● display the Max/Min temperature within an area of analysis Delivered with the RayCAm Report software RayCAm Report is the ideal tool for analysing the results and creating customized reports. Its interface is so simple that anyone can learn to use it very quickly. All the analysis functions are accessible via the toolbar. Depending on their requirements, users can position various elements: ● cursors (automatic display of the temperature at the point selected) ● thermal profile (automatic display of the Min/Max/Average temperatures of the line) ● a square or circle for area analysis (ideal for Min/Max/Average temperature comparisons between terminals, for example) ● Result tables quickly display all the data / analytical tools on the thermogram automatically ● The «Max» function automatically indicates the hottest point in the whole thermogram or in a predefined area of analysis. There are now also new functions available with the C.A 1886 and C.A 1888: ● Polygons and polylines for more precise analysis of certain areas in the thermogram ● A barchart for studying the temperature distribution according to several intervals Detector Type Frequency Sensitivity (NETD) Standard temp. range Temp. range with option Accuracy IR image Field of view Spatial resolution Min. focusing distance Focusing Real image Min. focusing distance IR-Merge Image size Emissivity correction Parameter settings Measurement tools Comments Storage Storage type Screen Battery Battery recharging Protection C.A 1884 C.A 1886 C.A 1888 Detector Specifications 160 x 120 384 x 288 UFPA microbolometer, 8-14 microns 50 Hz 0.1 °C to 30 °C 0.1 °C to 30 °C 0.08 °C to 30 °C Temperature Measurements -20 °C to +250 °C -20 °C to +600 °C 1,500 °C ±(2 °C + 2 %) image performance 20° x 15° 2.2 mrad 24° x 18° 1.3 mrad 10 cm Manual No - Yes 10 cm Complete IR-Merge functions IR image in real image from 0 to 100 % 640 x 480 pixels Other Functions Yes Ambient temperature in °C, distance, humidity 3 manual cursors + 1 auto Max/Min detection, adjustable, isotherm, high/low alarm Voice annotations (option) 1,000 (radiometric format) + 250 folders Internal 2 GB mini-SD Card 2.5 inches, multidirectional 3.5 inches, multidirectional General Battery life: 2.5 hrs Battery life: 3 hrs (continuous use) (continuous use) External battery charger IP 54 A wide range of accessories for measurements in optimum conditions: ● USB cable for data transfer onto a PC ● Video cable for display on external screen ● RayCAm Report software for processing the data This set of accessories is supplied as standard with your RayCAm in a hard case. ● Operation on internal batteries or mains adapter* ● Bluetooth accessories ● Sun-shade* to make the screen easy to read even in bright lighting ● Tripod adapter* for hands-free use and operation in a fixed position *Accessories available as an option Standard state at delivery: C.A 1884: delivered in a case with 1 battery charger, 1 battery, 1 USB cable, 1 video cable, RayCAm Report software and a measurement report. C.A 1886 or C.A 1888: delivered in a case with 1 battery charger, 2 batteries, a 2 GB mini-SD Card, 1 SD card reader, 1 video cable, RayCAm Report software and a measurement report. References to order: Accessories and replacement parts CA 1884 ................................................ P01651228 CA 1884 high temperature 600 °C............ P01651240 CA 1884 high temperature 1000 °C.......... P01651241 CA 1884 high temperature 1500 °C.......... P01651242 CA 1884 wide-angle lens 38°.................... P01651243 CA 1884 wide-angle lens 38° and standard lens 20°............................... P01651244 CA 1884 telephoto lens 6.4°..................... P01651245 CA 1884 telephoto lens 6.4° and standard lens 20°............................... P01651246 CA 1886................................................. P01651260 C.A 1886 high temperature 1000 °C......... P01651261 C.A 1886 high temperature 1500 °C......... P01651262 CA 1888................................................. P01651270 C.A 1888 high temperature 1000 °C......... P01651271 C.A 1888 high temperature 1500 °C......... P01651272 CA 1886 Bluetooth................................... P01651263 CA 1888 Bluetooth................................... P01651273 Photo tripod adapter................................... P01651526 Lens cap.................................................... P01651522 USB cable.................................................. P01295274 RayCAm Report.......................................... P01651524 Battery...................................................... P01296041 Battery charger.......................................... P01296043 Mains power supply.................................... P01651527 In-vehicle battery charger (cigarette lighter)..............................................HX0061 Thermography training ........................Please contact us FRANCE Chauvin Arnoux 190, rue Championnet 75876 PARIS Cedex 18 Tel: +33 1 44 85 44 86 Fax: +33 1 46 27 95 59 [email protected] www.chauvin-arnoux.fr united kingdom Chauvin Arnoux Ltd Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk Dewsbury, West Yorkshire - WF12 7TH Tel: +44 1924 460 494 Fax: +44 1924 455 328 [email protected] www.chauvin-arnoux.com middle east Chauvin Arnoux Middle East P.O. BOX 60-154 1241 2020 JAL EL DIB (Beirut) - LEBANON Tel: +961 1 890 425 Fax: +961 1 890 424 [email protected] www.chauvin-arnoux.com For assistance and ordering 906211220 - Ed. 3 - VS 10/2010 - Non contractual document. Confirm specifications before ordering. TECHNICAL SPECIFICATIONS