GENERAL C3217

Product Data Sheet
Part Number: C3217
Revision Level:
2
4-1/2P 24 7/32 TC FEP OAS PVDF
Date:
TYPE CMP, SHIELDED
A. CONSTRUCTION
Conductor:
Insulation:
Pairing
Cable:
Jacket:
Print Legend:
DIAMETERS
#24 AWG 7/32 Tinned Copper
0.024” nom.
0.045" nom.
0.011" Wall FEP
9 conductors into 4-1/2 pairs @ 1.50” LHL.
0.088" nom.
4-1/2 pairs @ 2.50”LHL, aluminum/polypro (foil in)
0.194" nom.
& # 24 7/32 TC drain wire.
0.010"Wall PVDF – Natural
0.214" +/- 0.118"
-Plenum ripcord under jacket.
CAROL (R) 24 AWG -- C3217 -- 150C E111240-8 CMP (UL) C(UL) -- MADE IN USA
DATE CODE (PRINT EVERY 2 FT)
B. INDUSTRY APPROVALS
National Electrical Code
UL Standard 444
Article 800
Type CMP (UL) C(UL)
C. ELECTRICAL PROPERTIES
TEMPERATURE:
SUGGESTED WORKING VOLTAGE (Vrms):
CONDUCTOR D.C. RESISTANCE:
D. COLOR CODE
1
2
3
4
5
150 C
300 Vrms
25.7 Ohms/1000 ft. nom. @ 20C
(Listed as Individual Conductors or Pairs of Conductors)
Black & Yellow
Red & Purple
Dark Blue & Brown
Orange & Dark Green
1C - Dark Green w/ Yellow Stripe
Note: Data are subject to change without notice. Contact your Customer Service representative for latest information.
*FLEXGUARD is a trademark of General Cable Corporation for polymer alloy insulation and jackets.
7/25/2007