Product Data Sheet Part Number: C3217 Revision Level: 2 4-1/2P 24 7/32 TC FEP OAS PVDF Date: TYPE CMP, SHIELDED A. CONSTRUCTION Conductor: Insulation: Pairing Cable: Jacket: Print Legend: DIAMETERS #24 AWG 7/32 Tinned Copper 0.024” nom. 0.045" nom. 0.011" Wall FEP 9 conductors into 4-1/2 pairs @ 1.50” LHL. 0.088" nom. 4-1/2 pairs @ 2.50”LHL, aluminum/polypro (foil in) 0.194" nom. & # 24 7/32 TC drain wire. 0.010"Wall PVDF – Natural 0.214" +/- 0.118" -Plenum ripcord under jacket. CAROL (R) 24 AWG -- C3217 -- 150C E111240-8 CMP (UL) C(UL) -- MADE IN USA DATE CODE (PRINT EVERY 2 FT) B. INDUSTRY APPROVALS National Electrical Code UL Standard 444 Article 800 Type CMP (UL) C(UL) C. ELECTRICAL PROPERTIES TEMPERATURE: SUGGESTED WORKING VOLTAGE (Vrms): CONDUCTOR D.C. RESISTANCE: D. COLOR CODE 1 2 3 4 5 150 C 300 Vrms 25.7 Ohms/1000 ft. nom. @ 20C (Listed as Individual Conductors or Pairs of Conductors) Black & Yellow Red & Purple Dark Blue & Brown Orange & Dark Green 1C - Dark Green w/ Yellow Stripe Note: Data are subject to change without notice. Contact your Customer Service representative for latest information. *FLEXGUARD is a trademark of General Cable Corporation for polymer alloy insulation and jackets. 7/25/2007