GENERAL C3352

Product Data Sheet
Part Number: C3352
Revision Level:
0
2P 22 7/30 TC FLEX OAS PVDF
Date:
TYPE CL2P
A. CONSTRUCTION
Conductor:
Insulation:
Pairing
Cable:
Jacket:
Print Legend:
DIAMETERS
#22 AWG 7/30 Tinned Copper
0.030” nom.
0.044" nom.
0.007" Wall FLEXGUARD*
4 conductors into 2 pairs @ 1.50” LHL.
2 pairs @ 2.50” LHL, aluminum/polypro (foil in)
0.137" nom.
& # 24 7/32 TC drain wire.
0.010"Wall PVDF – Natural
0.157" +/- 0.008"
-Plenum ripcord under jacket.
CAROL (R) 22 AWG -- C3352 -- 60C E60233-8 CL2P -- MADE IN USA
DATE CODE (PRINT EVERY 2 FT)
B. INDUSTRY APPROVALS
National Electrical Code
UL Standard 13
Article 725
Type CL2P
C. ELECTRICAL PROPERTIES
TEMPERATURE:
SUGGESTED WORKING VOLTAGE (Vrms):
CONDUCTOR D.C. RESISTANCE:
D. COLOR CODE
1
2
75C
150 Vrms (CL2P)
16.6 Ohms/1000 ft. nom. @ 20C
(Listed as Individual Conductors or Pairs of Conductors)
Black & Yellow
Red & Purple
Note: Data are subject to change without notice. Contact your Customer Service representative for latest information.