Product Data Sheet Part Number: C3364 Revision Level: 0 4P 18 7/26 BC FLEX OAS PVDF Date: TYPE CL2P / CMP A. CONSTRUCTION Conductor: Insulation: Pairing Cable: Jacket: Print Legend: DIAMETERS #18 AWG 7/36 Bare Copper 0.047” nom. 0.063" nom. 0.008" Wall FLEXGUARD* 8 conductors into 4 pairs @ 2.50” LHL. 4 pairs @ 4.00” LHL, aluminum/polypro (foil in) 0.357" nom. & # 22 7/30 TC drain wire. 0.010"Wall PVDF – Natural 0.277" +/- 0.014" -Plenum ripcord under jacket. CAROL (R) 18 AWG -- C3364 -- 60C E60233-8 CL2P OR CMP(UL)C(UL) -- MADE IN USA DATE CODE (PRINT EVERY 2 FT) B. INDUSTRY APPROVALS National Electrical Code UL Standard 13 Article 725 Type CL2P National Electrical Code UL Standard 444 Article 800 Type CMP C. ELECTRICAL PROPERTIES TEMPERATURE: SUGGESTED WORKING VOLTAGE (Vrms): CONDUCTOR D.C. RESISTANCE: D. COLOR CODE 1 2 3 4 75C 150 Vrms (CL2P); 300 Vrms (CMP) 5.6 Ohms/1000 ft. nom. @ 20C (Listed as Individual Conductors or Pairs of Conductors) Black & Yellow Red & Purple Dark Blue & Brown Orange & Dark Green Note: Data are subject to change without notice. Contact your Customer Service representative for latest information. *FLEXGUARD is a trademark of General Cable Corporation for polymer alloy insulation and jackets. 7/7/2007