Product Data Sheet Part Number: C3029 Revision Level: 5 3P 24 7/32 TC FEP OAS PVDF Date: TYPE CMP LOW-CAP CABLE A. CONSTRUCTION Conductor: Insulation: Pairing Cable: Jacket: Print Legend: DIAMETERS #24 AWG 7/32 Tinned Copper 0.024” nom. 0.048" nom. 0.012" Wall FEP 6 conductors into 3 pairs @ 1.75” LHL. 0.079" nom. 3 pairs @ 2.00” LHL, aluminum/polypro (foil in) 0.163" nom. & # 24 7/32 TC drain wire. 0.010"Wall PVDF – Natural 0.183" +/- 0.008" -Plenum ripcord under jacket. CAROL (R) 24 AWG -- C3029 -- 150C E111240-8 CMP (UL) C(UL) -- SHIELDED LO-CAP -MADE IN USA B. INDUSTRY APPROVALS National Electrical Code UL Standard 444 Article 800 Type CMP (UL) c(UL) C. ELECTRICAL PROPERTIES TEMPERATURE: SUGGESTED WORKING VOLTAGE (Vrms): CONDUCTOR D.C. RESISTANCE: D. COLOR CODE 1 2 3 7/25/2007 150 C 300 Vrms 25.7 Ohms/1000 ft. nom. @ 20C (Listed as Individual Conductors or Pairs of Conductors) Black & Yellow Red & Purple Dark Blue & Brown Note: Data are subject to change without notice. Contact your Customer Service representative for latest information. *FLEXGUARD is a trademark of General Cable Corporation for polymer alloy insulation and jackets.