RFSOLUTIONS DS-006-1

006
RF Signal Test Meter
Features:
•
Transmit and Receive modes,
•
4 Selectable Frequencies,
•
315MHz, 433MHz,
•
868MHz, 915MHz
•
Long Battery Life
•
Small Size
•
Simple to use
Applications
•
Detect Radio Interference
•
Range Testing
•
Pre-Installation Performance
•
•
Check
Transmitter Checking
Description
RF Solutions 006 is a versatile handheld test meter checking Radio signal strength or interference in a given area.
The 006 can both transmit and receive signals making it possible to test an installation
location for suitability before installing equipment. The 006 is very hard wearing, long
lasting and simple to use. It has 4 selectable frequencies, changeable at the touch of a
button. It also has an auto shut off feature for battery saving.
Ref: DS-006-1
Release: May 2011
006
Operating Instructions
Spot Frequencies used:
•
315.00MHz
•
433.92MHz
•
868.95MHz
•
915.00MHz
Functions:
The 006 has two functions:
Transmit - The 006 sends out a pulsed transmission which can be received by a module on the
frequency selected. Or by another 006 set to the same module.
Transmit power: the 006 transmits at 0dBm
Transmit timing: the 006 sends a 100ms pulse every 1 second
Transmit signal modulation: a 1KHz sine wave is modulated over the transmit signal.
Receive - when set in receive mode the 006 displayed any signals detected in the selected frequency.
The receive sensitivity is shown on the front panel (as below)
Antenna:
As standard the 006 is fitted with a 433.92MHz antenna, this should be sufficient for most applications,
however other antennas are available from RF Solutions website for improved performance on specific
frequencies. See www.rfsolutions.co.uk for more details.
Ref: DS-006-1
Release: June 11
Page 2
006
Technical Specification
Dimensions: 90 x 54 x 27mm
Antenna: 17.5cm (433.93MHz)
Supply voltage
Min
Typical
Max
Units
2.2
3
3.3
V
Frequency
Bandwidth
Max. RF Input
See
RF Sensitivity
Operating Temperature
Storage Temperature
315.00
MHz
433.92
MHz
868.95
MHz
915.00
MHz
1
MHz
+20
dBm
Sticker
Overlay
dBm
0
+50
o
C
-20
+60
o
C
RF Solutions Ltd. Recycling Notice
DO NOT
Discard with normal waste, please recycle.
Meets the following EC Directives:
ROHS Directive 2002/95/EC
Specifies certain limits for hazardous substances.
WEEE Directive 2002/96/EC
Waste electrical & electronic equipment. This product must be disposed of
through a licensed WEEE collection point. RF Solutions Ltd., fulfills its WEEE obligations by membership of an approved compliance scheme.
Waste Batteries and Accumulators
Directive 2006/66/EC
Where batteries are fitted, before recycling the
product, the batteries must be
removed and disposed of at a licensed
collection point.
Environment Agency producer registration number:
WEE/JB0104WV.
Whilst the information in this document is believed to be correct at the time of issue, RF Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or completeness. No express or implied warranty or representation is given relating to the information contained in this document. RF Solutions Ltd reserves the
right to make changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of
any such information or products for their own particular requirements or specification(s). RF Solutions Ltd shall not be liable for any loss or damage caused as a result
of user’s own determination of how to deploy or use RF Solutions Ltd’s products. Use of RF Solutions Ltd products or components in life support and/or safety applications is not authorised except with express written approval. No licences are created, implicitly or otherwise, under any of RF Solutions Ltd’s intellectual property rights.
Liability for loss or damage resulting or caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where RF Solutions Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict RF Solutions Ltd’s liability
for death or personal injury resulting from its negligence.
Page 3