MILLENIUM INSTALLATION MANUAL NTR 735 A/E Simple Automation Control Module (MAS) MAS INSTALLATION MANUAL NTR 735 A Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed for use in domestic, office and industrial applications. Each module can be used to manage all the sensors and actuators in the installation. A display on the front panel can be used to check the state of your system at any time. The MILLENIUM series is characterised by : • Ease of programming and parameter entry • WINDOWS-based programming software • Compact size • EEPROM module backup • Realtime clock as standard • Output with high breaking capacity The MILLENIUM series has been designed for simple automation control modules (examples : lighting, air conditioning, irrigation, doors, barriers, simple safety systems, greenhouses, ventilation). The realtime clock allows equipment to be programmed in hours or minutes. Simple Automation Control Module (MAS) ntr_735a_e_mas_installation_manual.doc 07/1999 - 1/8 MAS INSTALLATION MANUAL NTR 735 A 2. Hardware description 2.1 Part numbers Codes Part numbers Power supply Inputs Type MAS 6 RCA 100 - 240V AC 100 - 240V AC MAS 10 RCA 100 - 240V AC 100 - 240V AC MAS 10 RCD 24V DC 24V DC MAS 20 RCA* 100 - 240V AC 100 - 240V AC MAS 20 RCD* 24V DC 24V DC 89 750 001 89 750 002 89 750 003 89 750 004 89 750 005 * Available from Q4/1999. 2.2 No. 4 6 6 12 12 Outputs Type No. RELAY 2 RELAY 4 RELAY 4 RELAY 8 RELAY 8 Dimensions mm Weight kg 71.2 x 90 x 55 0.2 124.6 x 90 x 55 Description of power supplies Description Power supply Micro-cuts Current peak Maximum consumption Typical consumption Code MAS x RCA MAS x RCD MAS x RCA MAS x RCD 240V AC 24 V DC MAS 6 RCA, MAS 10 RCA, MAS 10 RCD, MAS 6 RCA, MAS 6 RCA, MAS 10 RCA, MAS 10 RCA, MAS 10 RCD, MAS 20 RCA, MAS 20 RCA, 264V AC 264V AC 28.8V DC 240V AC 120V AC 240V AC 120V AC 24V DC 240V AC 120V AC Specification 100 - 240V AC, +10% -15%, 50/60 Hz 24V DC, +20% -15% 10ms 5ms ≤ 1.5 A t < 0.3 ms ≤ 7 A t < 0.2 ms 3 VA 4 VA 3W active I/O : 2.5 VA, deactivated I/O : 1.5 VA active I/O : 2 VA, deactivated I/O : 1.2 VA active I/O : 3 VA, deactivated I/O : 1.5 VA active I/O : 2 VA, deactivated I/O : 1.2 VA active I/O : 2 W, deactivated I/O : 0.3 W Simple Automation Control Module (MAS) ntr_735a_e_mas_installation_manual.doc 07/1999 - 2/8 MAS INSTALLATION MANUAL 2.3 NTR 735 A Description of inputs Description Input voltage Input impedance Level 0 Level 1 Response time Galvanic isolation Status indication Description of AC inputs 100 - 240V AC, +10% -15%, 50/60 Hz ≥ 800 k Ohms ≤ 40V AC ≥ 80V AC 25 ms min, 130 ms max. No LCD display Description Input voltage Current consumption Level 0 Level 1 Response time Galvanic isolation Status indication Description of DC inputs 24V DC +20% -15% 5 mA ≤ 4V ≥ 18V 15 ms No LCD display Description MAS 10 RCD MAS 20 RCD Number of bits Resolution Conversion time Input voltage Input impedance Precision Default Offset/ Gain Description of analogue inputs 6 Inputs: I 01 – I 06 8 Inputs: I 01 – I 08 8 (10000 / 250) mV 15 +/- 5ms 0 - 10V DC 150 k Ohms max. +/- 5% Offset = 0 Gain = 1 These values can be changed by the program +/- 3 LSB on the authorised range Temp. dependent derating 2.4 Description of relay outputs Description Max. operating voltage Max. operating current Minimum load Response time Type of contact Status indication Category of use AC15 (electromagnet) DC13 (electromagnet) (L/R = 150 ms) AC14 (electromagnet) AC12 (resistive) DC12 (resistive) Description of relay outputs 250V AC, 30V DC 8A / point 10mA at 5V DC ≤ 10ms Gold-plated silver LCD display Max. operating voltage 250V AC 30V DC 250V AC 250V AC 30V DC Power consumption Durability in steady state (number of operations) 450 VA 100000 10 W 100000 750 VA 2000 VA 192 W 100000 100000 100000 Max. ops / hour 600 360 600 1800 1800 Simple Automation Control Module (MAS) ntr_735a_e_mas_installation_manual.doc 07/1999 - 3/8 MAS INSTALLATION MANUAL 2.5 NTR 735 A General description Description Programming Program capacity Program backup Data backup Clock backup LCD display Specification Logic block or function block 64 blocks or 1500 bytes Via internal EEPROM or optional external EEPROM module 20 days at 25° C (via capacitor) 20 days at 25° C (via capacitor) Display unit with 4 lines of 10 characters. Climatic conditions : Type Operating temperature Storage temperature Humidity Degree of protection Environment Standard Amplitude 0/55 °C -30/70 °C 35 - 85% relative humidity, without condensation IP 20 No corrosive gases. Minimum dust Type Resistance to vibrations Direct mounting Standard JIS C0040 Resistance to vibrations Mounted on DIN rail JIS C0040 Resistance to shocks JIS C0041 Amplitude 10- 57 Hz: 0.15 mm Constant amplitude Acceleration 57- 150 Hz 9.8 m/ s² X, Y, Z : 10 times (80 minutes in each direction) 10- 57 Hz: 0.07 mm Constant amplitude Acceleration 57- 150 Hz: 4.9 m/s² X, Y, Z : 10 times (80 minutes in each direction) Acceleration : 147m/s², duration: 11 ms X, Y, Z : 3 times in each direction Type Dielectric strength Standard EN 60730-1 Insulation resistance EN 60730-1 Mechanical protection : Safety class Certifications Conformity Amplitude 3750V AC > 1 min between the following points : Power supply terminals / input / output terminals Between the relay outputs Between the terminals and the DIN 43880 control box or equivalent 7 Mohm at 500V DC between the following points : Power supply terminals / input / output terminals Between the relay outputs Between the terminals and the DIN 43880 control box or equivalent II CE Low Voltage directive 73/23/EEC EMC directive 89/336/EEC UL/ cUL UL 508 EN60730- 1 EN61010- 1 EN50081- 1 EN50082- 1 EN50082- 2 Simple Automation Control Module (MAS) ntr_735a_e_mas_installation_manual.doc 07/1999 - 4/8 MAS INSTALLATION MANUAL NTR 735 A 3. Installation L N NC NC POWER AC 100/240V 1 2 3 IN 4 5 6 Ref. Description of front panel Programming port 1 EEPROM backup module 2 Fixing holes, ∅ : 4.2 mm Power supply terminals 3 Input terminals 4 LCD display 5 Menu keys 6 Output terminals 7 DIN rail mounting 8 AC INPUT ESC OK MAS 10 RCA RELAY OUTPUT 3.1 DIN rail mounting The modules can be mounted on a 35 mm DIN rail (DIN EN 50022). 3.2 Panel mounting Recommended diameter of fixing screws : M4. 3.3 Screw terminal connection The end of the wire should be fitted with a ferrule. 3.4 Mounting instructions The MILLENIUM series can be installed anywhere, but the following points should be taken into consideration. Do not install if : the atmosphere is excessively dusty, conductive, corrosive, gas-laden, damp, wet or inflammable, or subject to excessive heat*, excessive shocks or vibrations. Do not install the module in water or near any possible leaks. Protect the module from external debris during installation. Separate the cables and power equipment as far as possible. The MILLENIUM series module should be installed in cabinets which adhere to standard DIN 43880. ! * For sufficient module ventilation, allow a space of 10 mm between the front of the module and the cabinet door, and likewise between the base of the cabinet and the bottom of the module. 6 4 10 L N NC NC 1 POWER AC 100/240V 2 3 IN 4 5 6 AC INPUT CROUZET AUTOMATISMES MADE IN JAPAN MAS 10 RCA 89 750 002 MODEL : REF : SERIAL : ESC 90 OK MAS 10 RCA RELAY OUTPUT 4 10 55 6 71 Simple Automation Control Module (MAS) ntr_735a_e_mas_installation_manual.doc 07/1999 - 5/8 MAS INSTALLATION MANUAL NTR 735 A 4. Connection 4.1 Connection instructions The MILLENIUM series has been designed with ease of connection in mind. A technician or engineer with experience of national and local electrical standards should be able to connect MILLENIUM series modules to the sensors and actuators without difficulty. • The input and output cables should not be in the same wiring harness. • Keep the input/output wiring harnesses well away from the power wiring harnesses. • Use cables which are suitable for the application. ! 4.2 Conductor cross-section ! For the inputs / outputs use conductors : 0.13 mm² - 3.31 mm² (26 - 12 AWG). Strip back the conductor by 7 ± 0.5 mm. Undo the terminal screw to its maximum before inserting a conductor. To be sure of correct connection, insert the wire fully in the terminal and tighten the screws. Maximum tightening torque 0.5 Nm (5kgfcm). Do not coat the conductor ends with tin to prevent them breaking. 4.3 Power supply For an AC power supply, the phase should be connected to the L terminal and the Neutral to the N terminal. Never connect the phase to the N terminal, as the user could receive a dangerous electric shock. For a DC power supply, the positive conductor should be connected to the ‘+’ terminal and the negative conductor to the ‘-’ terminal. The power supply terminals should not be connected to the other module terminals. Simple Automation Control Module (MAS) ntr_735a_e_mas_installation_manual.doc 07/1999 - 6/8 MAS INSTALLATION MANUAL 4.4 NTR 735 A Wiring diagram L N L N NC NC 1 2 3 4 INPUTS 5 6 _ + + + - (A) (B) 1 2 3 4 INPUTS 5 6 (A) (B) 1 2 3 4 INPUTS 5 6 _ _ + - OUT1 OUT2 OUT3 OUT4 + or Simple Automation Control Module (MAS) ntr_735a_e_mas_installation_manual.doc 07/1999 - 7/8 MAS INSTALLATION MANUAL NTR 735 A 5. User safety and protection of equipment • This manual contains all the diagrams and explanations which will guide the user in installing and using MILLENIUM products correctly. This manual should be read and understood prior to use or installation. • If you have any doubts while installing MILLENIUM products or require any further information, consult your Crouzet distributor. • This manual may be amended without prior notification. This manual is intended for use by competent personnel trained in installation of this equipment as defined in the following European directives : Machinery (98/37/EEC) Low voltage (73/23/EEC) EMC (89/336/EEC). Installation and electrical connections must be performed by a qualified technician. This manual uses the symbols below to highlight information relating to the safety of personnel and the protection of equipment. Where these symbols appear, the associated comments should be read and understood. The symbols are : The identified danger will cause material damage. ! The identified danger is liable to cause material damage. • In no circumstances can Crouzet Limited be held responsible for damage arising as a result of installing or using this equipment. • All examples and diagrams in this manual are intended to aid comprehension. Their application is entirely the responsibility of the user. Crouzet Limited will not accept any responsibility for actual use of this product based on these examples. • It is up to the user to assess the suitability of this product for his applications. • In the event of product malfunction, the integral safety features should prevent dangerous situations. • Never modify or repair MILLENIUM products. • Check that MILLENIUM products comply with existing national and local standards. Simple Automation Control Module (MAS) ntr_735a_e_mas_installation_manual.doc 07/1999 - 8/8