ETC 103114

Technical Data Sheet
Product 222
Worldwide Version, October 1995
TYPICAL APPLICATIONS
Prevents loosening through vibration and leakage of threaded
fasteners.
Particularly suitable for applications such as
adjustment of set screws, small diameter or long engagement
length fasteners where easy disassembly is required without
shearing the screw.
135
>93
90 to 180
m
hro
Dic
ate
50
25
l
tee
sS
s
e
inl
Sta
s
as
Br
0
5min 10min
30min 1hr
3hr
6hr
5m
m
30min 1hr
3hr
6hr
24hr
72hr
Cure speed vs. temperature
The rate of cure will depend on the ambient temperature.
Graph below shows the breakaway strength developed with time
at different temperatures on M10 steel nuts and bolts and
tested according to ISO 10964.
24hr
72hr
Cure Time, Hours
Cure speed vs. bond gap
The rate of cure will depend on the bondline gap. Gaps in
threaded fasteners depend on thread type, quality and size. The
following graph shows shear strength developed with time on
steel pins and collars at different controlled gaps and tested
according to ISO 10123.
75
50
25
0
5min10min
30min 1hr
3hr
24hr 72hr
6hr
Cure Time, Hours
Cure speed vs. activator
Where cure speed is unacceptably long, or large gaps are
present, applying activator to the surface will improve cure
speed. The graph below shows breakaway strength developed
with time using ACTIVATOR N and T on M10 Zinc Dichromate
steel nuts & bolts and tested according to ISO 10964.
% of Full Strength on Steel
% of Full Strength on Steel
Cure speed vs. substrate
The rate of cure will depend on substrate used. The graph below
shows the breakaway strength developed with time on M10
steel nuts and bolts compared to different materials and tested
according to ISO 10964.
c
Zin
5min 10min
5°
C
2,500 to 7,500
800 to 1,600
75
0
100
5,000
1200
l
ee
St
25
Cure Time, Hours
TYPICAL CURING PERFORMANCE
100
50
m
5m
0.2
22
°C
Specific Gravity @ 25°C
Viscosity @ 25°C, mPa.s (cP)
Brookfield RVF
Spindle 3 @ 2 rpm
@ 20 rpm
DIN 54453, MV
D = 277 s-1 after t=180secs
Flash Point (TCC), °C
Range
75
40°
C
Chemical Type
Appearance
Typical
Value
Dimethacrylate ester
Opaque Purple,
Fluorescent Liquid
1.05
m
5m
0.1
% of Full Strength on Steel
PROPERTIES OF UNCURED MATERIAL
100
0.0
% of Full Strength on Steel
PRODUCT DESCRIPTION
LOCTITE® Product 222 is a single component anaerobic
threadlocking material, which is thixotropic and develops low
strength for easy disassembly. The product cures when
confined in the absence of air between close fitting metal
surfaces.
100
or
at
tiv
c
A
No
75
t T
Ac
50
tN
Ac
25
0
5min10min
30min 1hr
3hr
6hr
24hr 72hr
Cure Time, Hours
TYPICAL PROPERTIES OF CURED MATERIAL
Physical Properties
Coefficient of thermal expansion, ASTM D696, K-1
Coefficient of thermal conductivity, ASTM C177, W.m-1 K-
80 x10-6
0.1
Specific Heat , kJ.kg-1 K-1
0.3
1
NOT FOR PRODUCT SPECIFICATIONS.
THE TECHNICAL DATA CONTAINED HEREIN ARE INTENDED AS REFERENCE ONLY.
PLEASE CONTACT LOCTITE CORPORATION QUALITY DEPARTMENT FOR ASSISTANCE AND RECOMMENDATIONS ON SPECIFICATIONS FOR THIS PRODUCT.
ROCKY HILL, CT FAX: +1 (860)-571-5473
DUBLIN, IRELAND FAX: +353-(1)-451 - 9959
TDS 222, October 1995
PERFORMANCE OF CURED MATERIAL
For safe handling information on this product, consult the
Material Safety Data Sheet, (MSDS).
(After 24 hr at 22°C on M10 steel nuts & bolts)
Typical
Value
6
(53)
4
(30)
14
(120)
14
(120)
Breakaway Torque, ISO 10964, N.m
(lb.in)
Prevail Torque, ISO 10964, N.m
(lb.in)
Breakloose Torque, DIN 54454, N.m
(lb.in)
Max. Prevail Torque, DIN 54454, N.m
(lb.in)
Range
3 to 9
(25 to 80)
1 to 6
(10 to 50)
8 to 20
(71 to 180)
8 to 20
(71 to 180)
Where aqueous washing systems are used to clean the
surfaces before bonding, it is important to check for compatibility
of the washing solution with the adhesive. In some cases these
aqueous washes can affect the cure and performance of the
adhesive.
This product is not normally recommended for use on plastics
(particularly thermoplastic materials where stress cracking of
the plastic could result). Users are recommended to confirm
compatibility of the product with such substrates.
TYPICAL ENVIRONMENTAL RESISTANCE
Test Procedure :
Breakloose Torque, DIN 54454
Substrate:
M10 Zinc Phosphate Nuts & Bolts
Cure procedure:
1 week at 22°C
Directions for use
For best performance surfaces should be clean and free of
grease. Product should be applied to the bolt in sufficient
quantity to fill all engaged threads. This product performs best in
thin bond gaps, (0.05mm). Very large thread sizes may create
large gaps which will affect cure speed and strength. This
product is designed to give controlled friction, (torque/tension
ratio), during assembly. In critical tightening applications this
ratio should be confirmed.
Hot Strength
Tested at temperature.
% RT Strength
100
75
Storage
Product shall be ideally stored in a cool, dry location in
unopened containers at a temperature between 8°C to 28°C
(46°F to 82°F) unless otherwise labelled. Optimal storage is at
the lower half of this temperature range.
To prevent
contamination of unused product, do not return any material to
its original container. For further specific shelf life information,
contact your local Technical Service Centre.
50
25
0
0
50
100
150
Temperature, °C
Data Ranges
The data contained herein may be reported as a typical value
and/or range (based on the mean value ±2 standard deviations).
Values are based on actual test data and are verified on a
periodic basis.
Heat Aging
Aged at temperature indicated and tested at 22°C.
% Initial Strength at RT
125
100
120°C
75
50
150°C
25
0
0
1,000
2,000
3,000
4,000
5,000
Hours
Chemical / Solvent Resistance
Aged under conditions indicated and tested at 22°C.
Solvent
Temp
.
% Initial Strength retained at
100
hr
Motor Oil
Leaded Petrol
Brake Fluid
Water/Glycol
(50%/50%)
Ethanol
Acetone
500
hr
1000 hr
5000 hr
125°
C
22°C
22°C
87°C
100
95
90
85
95
95
80
95
95
80
95
95
80
95
90
80
22°C
22°C
95
100
95
90
90
90
90
90
Note
The data contained herein are furnished for information only and
are believed to be reliable. We cannot assume responsibility for
the results obtained by others over whose methods we have no
control. It is the user's responsibility to determine suitability for
the user's purpose of any production methods mentioned herein
and to adopt such precautions as may be advisable for the
protection of property and of persons against any hazards that
may be involved in the handling and use thereof. In light of the
foregoing, Loctite Corporation specifically disclaims all
warranties expressed or implied, including warranties of
merchantability or fitness for a particular purpose, arising from
sale or use of Loctite Corporation’s products.
Loctite
Corporation specifically disclaims any liability for consequential
or incidental damages of any kind, including lost profits. The
discussion herein of various processes or compositions is not to
be interpreted as representation that they are free from
domination of patents owned by others or as a license under
any Loctite Corporation patents that may cover such processes
or compositions. We recommend that each prospective user
test his proposed application before repetitive use, using this
data as a guide. This product may be covered by one or more
United States or foreign patents or patent applications.
GENERAL INFORMATION
This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as a
sealant for chlorine or other strong oxidising materials.
Loctite is a Registered Trademark of Loctite Corporation, Hartford, CT 06106