ETC 9-1393792-9

D2 Titel_ok
22.09.1999
12:12 Uhr
Seite 2
Small Relay D2 neutral
Product Information
Small Relay D2 neutral
V23105
PCB relay for DC operation,
neutral, monostable
Features
O
All purpose relay with 2 changeover contacts,
suitable for a wide range of applications
O
Four different coil versions available
(150, 200, 400, 500 mW)
O
The switching capacity ranges from low signal up to 3 A
O
Standard Pinning
O
High-voltage resistance according to FCC Part 68:
1.5 kV (10/160 µs)
ECR1029-R
Approx. 1.5 x original size
Typical applications
Version
O
Communications technology
–
Monostable, 1 winding
O
Telecommunications terminal and accessories
–
With 2 changeover contacts
O
Entertainment electronics
–
For printed circuits assembling
O
Measurement and control equipment
–
Plastic case
–
Immersion cleanable
Approvals
UL
File E 48393
CSA
File LR 45064-27
British Telecom BT47W
Spec. T4563c
Dimension drawing (in mm)
Mounting hole layout
Terminal assignment
View on the terminals
View on the terminals
ECR1541-6
Basic grid 2.54 mm according to EN 60097 and DIN 40803
2
Siemens Electromechanical Components
Small Relay D2 neutral
Contact data
Number of contacts and type
2 changeover contacts
Contact assembly
single contacts
Contact material
Silver nickel, gold-plated,
against silver nickel, gold-plated
Max. continous current at max. ambient temperature
3A
Maximum switching current
3A
Maximum switching voltage
250 VDC
230 VAC
Maximum switching capacity
DC voltage
AC voltage
60 W, see load limit curve
120 VA
Recommended for load voltages greater than
10 mV
Thermoelectrical potential
< 15 µV
≤ 100 mΩ / 10 mA / 20 mV
Contact resistance (initial value) / measuring current / driver voltage
Load limit curve
ECR2265-5
300
250
U [VDC]
200
150
100
80
60
50
40
30
20
60
30
10
0.1
0.2
0.3
0.4
0.5 0.6
0.8
1
1.5
2
W
W
3
4
5
I [A]
I = switching current
U = switching voltage
= recommended application field
Load limit curve: Quenching of the arc during the transit time
Siemens Electromechanical Components
3
Small Relay D2 neutral
Coil data
Nominal voltages
from 3 VDC to 48 VDC
Nominal power consumption of the various coil versions
150 mW
200 mW
400 mW
500 mW
Maximum operating voltage
150 mW
200/400/500 mW
80% of the nominal voltage *)
70% of the nominal voltage
Minimum release voltage
5% of the nominal voltage
*) < 80% of the nominal voltage on request
UI =
Minimum voltage at 20 °C with after pre-energizing
with nominal voltage without contact current
Maximum continuous voltage at 20 °C
UII =
ECR2266-D
1.3
The operating voltage limits UI and UII are dependent on the temperature according to the formulae:
UI tamb
and
UII tamb
= kI · UI 20 °C
tamb
UI tamb
UII tamb
kI a. kII
=
=
=
=
= kII · UII 20 °C
Ambient temperature
Minimum voltage at ambient temperature tamb
Maximum voltage at ambient temperature tamb
Factors (dependent on temperature), see diagram
k-Factor
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
-30 -20 -10
0
10
20 30
40
50
60 70 80 85
Ambient temperature tamb [°C]
4
Siemens Electromechanical Components
Small Relay D2 neutral
Coil versions
Nominal voltage
Unom
Operating voltage range
at 20 °C
Resistance
at 20 °C
Coil number
Ordering code block 2
Minimum voltage UI
Maximum voltage UII
VDC
VDC
3
2.4
10.2
60
±
6
008
001
VDC
Ω
150 mW nominal power consumption
5
4.0
13.0
167
±
16.7
6
4.8
15.6
240
±
24
002
9
7.2
23.4
540
±
54
006
12
9.6
31.2
960
±
96
003
24
19.2
59.5
3480
± 348
005
200 mW nominal power consumption
3
2.1
6.7
45
±
4.5
308
5
3.5
11.2
125
±
12.5
301
6
4.2
13.5
180
±
18
302
9
6.3
20.3
405
±
40.5
306
±
12
8.4
27.0
720
72
303
24
16.8
54.1
2880
± 288
305
48
33.6
108.3
11520
± 1152
307
400 mW nominal power consumption
5
3.5
7.9
62
±
6.2
401
6
4.2
9.5
90
±
9
402
406
9
6.3
14.3
203
±
20.3
12
8.4
19.1
360
±
36
403
24
16.8
38.3
1440
± 144
405
48
33.6
76.6
5760
± 576
407
501
500 mW nominal power consumption
5
3.5
6.3
36
±
3.6
6
4.2
8.9
70
±
7
502
9
6.3
12.5
140
±
14
506
10
7.0
15.0
200
±
20
504
12
8.4
17.8
280
±
28
503
24
16.8
34.4
1050
± 105
505
48
33.6
67.3
4000
± 400
507
Coil versions, BT 47 type / specification T4563C (current tested)
Nominal voltage
Unom
VDC
Operating current
Resistance
at 20 °C
British Telecom Code
Coil number
Ordering code block 2
47W/5
475
47W/9
479
Ω
mA
5
80.0
36
±
10
32.5
200
±
20
12
27.0
280
±
28
47W/6
476
24
14.0
1050
± 105
47W/7
477
48
7.0
4000
± 400
47W/8
478
Siemens Electromechanical Components
3.6
5
Small Relay D2 neutral
General data
Operate time at Unom and 20 °C, typ.
5 ms
Release time at Unom without parallel diode, typ.
4 ms
Bounce time, typ.
3 ms
Maximum switching rate without load
20 operations/s
Ambient temperature according to
DIN IEC 61810-1 or VDE 0435 Part 201
150/200 mW nominal power consumption
400 mW nominal power consumption
500 mW nominal power consumption
-25 °C ... +85 °C
-25 °C ... +70 °C
-25 °C ... +60 °C
Thermal resistance
approx. 100 K/W
Maximum permissible coil temperature
105 °C
Vibration resistance,
10 to 55 Hz according to IEC 60068-2-6
55 to 500 Hz according to IEC 60068-2-6
function:10 g
damage: 20 g
Shock resistance, half sinus, 11 ms
according to IEC 68068-2-27
function:10 g
damage: 40 g
Degree of protection
according to VDE 0470 Part 1 EN 60529 / IEC 60529
Capacitance at 1 kHz, 100 VAC
between open contacts
between closed contacts
between contact and coil
Electrical endurance at resistive load
6 VDC / 100 mA
30 VDC / 1 A
30 VDC / 2 A (only 400 and 500 mW coils)
230 VAC / 500 mA
Mechanical endurance
Mounting position
Processing information
Weight
immersion cleanable, IP 67
< 2 pF
< 1.5 pF
< 5 pF
> 2 x 106 operations
approx. 5 x 105 operations
approx. 1 x 105 operations
> 3 x 105 operations
15 x 106 operations
any
Ultrasonic cleaning is not recommended
approx. 6 g
Insulation
Insulation resistance at 500 V
Dielectric test voltage (1 min)
contact/winding
changeover contact/changeover contact
at open contact
Surge voltage resistance
according to FCC 68 (10/160 µs)
6
≥ 1000 MΩ
1000 VACrms / 1500 VDC
750 VACrms / 1000 VDC
750 VACrms / 1000 VDC
1500 V
Siemens Electromechanical Components
Small Relay D2 neutral
Ordering code
V 2 3 1 0 5
A 5
A 2 0 1
Identification of the
small relay D2 neutral
Version
0 = 150 mW nominal power consumption
3 = 200 mW
4 = 400 mW
5 = 500 mW
Coil number
08 = 3 V nominal voltage (only coils with 150/200 mW nominal power consumption*)
01 = 5 V nominal voltage
02 = 6 V
06 = 9 V
04 = 10 V (only coil with 500 mW nominal power consumption)
03 = 12 V
05 = 24 V
07 = 48 V (not coil with 150 mW nominal power consumption)
BT 47 versions
475 = 5 V nominal voltage
479 = 10 V
476 = 12 V
477 = 24 V
478 = 48 V
Contact assembly / material
A201 = 2 changeover contacts, silver nickel, gold-plated, against silver nickel, gold-plated
*) Coils with 400/500 mW nominal power consumption on request
Ordering example: V23105-A5301-A201
Small relay D2 neutral, coil 5 V nominal voltage, 200 mW nominal power consumption,
Contact material silver nickel, gold-plated, against silver nickel, gold-plated
Siemens Electromechanical Components
7