D2 Titel_ok 22.09.1999 12:12 Uhr Seite 2 Small Relay D2 neutral Product Information Small Relay D2 neutral V23105 PCB relay for DC operation, neutral, monostable Features O All purpose relay with 2 changeover contacts, suitable for a wide range of applications O Four different coil versions available (150, 200, 400, 500 mW) O The switching capacity ranges from low signal up to 3 A O Standard Pinning O High-voltage resistance according to FCC Part 68: 1.5 kV (10/160 µs) ECR1029-R Approx. 1.5 x original size Typical applications Version O Communications technology – Monostable, 1 winding O Telecommunications terminal and accessories – With 2 changeover contacts O Entertainment electronics – For printed circuits assembling O Measurement and control equipment – Plastic case – Immersion cleanable Approvals UL File E 48393 CSA File LR 45064-27 British Telecom BT47W Spec. T4563c Dimension drawing (in mm) Mounting hole layout Terminal assignment View on the terminals View on the terminals ECR1541-6 Basic grid 2.54 mm according to EN 60097 and DIN 40803 2 Siemens Electromechanical Components Small Relay D2 neutral Contact data Number of contacts and type 2 changeover contacts Contact assembly single contacts Contact material Silver nickel, gold-plated, against silver nickel, gold-plated Max. continous current at max. ambient temperature 3A Maximum switching current 3A Maximum switching voltage 250 VDC 230 VAC Maximum switching capacity DC voltage AC voltage 60 W, see load limit curve 120 VA Recommended for load voltages greater than 10 mV Thermoelectrical potential < 15 µV ≤ 100 mΩ / 10 mA / 20 mV Contact resistance (initial value) / measuring current / driver voltage Load limit curve ECR2265-5 300 250 U [VDC] 200 150 100 80 60 50 40 30 20 60 30 10 0.1 0.2 0.3 0.4 0.5 0.6 0.8 1 1.5 2 W W 3 4 5 I [A] I = switching current U = switching voltage = recommended application field Load limit curve: Quenching of the arc during the transit time Siemens Electromechanical Components 3 Small Relay D2 neutral Coil data Nominal voltages from 3 VDC to 48 VDC Nominal power consumption of the various coil versions 150 mW 200 mW 400 mW 500 mW Maximum operating voltage 150 mW 200/400/500 mW 80% of the nominal voltage *) 70% of the nominal voltage Minimum release voltage 5% of the nominal voltage *) < 80% of the nominal voltage on request UI = Minimum voltage at 20 °C with after pre-energizing with nominal voltage without contact current Maximum continuous voltage at 20 °C UII = ECR2266-D 1.3 The operating voltage limits UI and UII are dependent on the temperature according to the formulae: UI tamb and UII tamb = kI · UI 20 °C tamb UI tamb UII tamb kI a. kII = = = = = kII · UII 20 °C Ambient temperature Minimum voltage at ambient temperature tamb Maximum voltage at ambient temperature tamb Factors (dependent on temperature), see diagram k-Factor 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 -30 -20 -10 0 10 20 30 40 50 60 70 80 85 Ambient temperature tamb [°C] 4 Siemens Electromechanical Components Small Relay D2 neutral Coil versions Nominal voltage Unom Operating voltage range at 20 °C Resistance at 20 °C Coil number Ordering code block 2 Minimum voltage UI Maximum voltage UII VDC VDC 3 2.4 10.2 60 ± 6 008 001 VDC Ω 150 mW nominal power consumption 5 4.0 13.0 167 ± 16.7 6 4.8 15.6 240 ± 24 002 9 7.2 23.4 540 ± 54 006 12 9.6 31.2 960 ± 96 003 24 19.2 59.5 3480 ± 348 005 200 mW nominal power consumption 3 2.1 6.7 45 ± 4.5 308 5 3.5 11.2 125 ± 12.5 301 6 4.2 13.5 180 ± 18 302 9 6.3 20.3 405 ± 40.5 306 ± 12 8.4 27.0 720 72 303 24 16.8 54.1 2880 ± 288 305 48 33.6 108.3 11520 ± 1152 307 400 mW nominal power consumption 5 3.5 7.9 62 ± 6.2 401 6 4.2 9.5 90 ± 9 402 406 9 6.3 14.3 203 ± 20.3 12 8.4 19.1 360 ± 36 403 24 16.8 38.3 1440 ± 144 405 48 33.6 76.6 5760 ± 576 407 501 500 mW nominal power consumption 5 3.5 6.3 36 ± 3.6 6 4.2 8.9 70 ± 7 502 9 6.3 12.5 140 ± 14 506 10 7.0 15.0 200 ± 20 504 12 8.4 17.8 280 ± 28 503 24 16.8 34.4 1050 ± 105 505 48 33.6 67.3 4000 ± 400 507 Coil versions, BT 47 type / specification T4563C (current tested) Nominal voltage Unom VDC Operating current Resistance at 20 °C British Telecom Code Coil number Ordering code block 2 47W/5 475 47W/9 479 Ω mA 5 80.0 36 ± 10 32.5 200 ± 20 12 27.0 280 ± 28 47W/6 476 24 14.0 1050 ± 105 47W/7 477 48 7.0 4000 ± 400 47W/8 478 Siemens Electromechanical Components 3.6 5 Small Relay D2 neutral General data Operate time at Unom and 20 °C, typ. 5 ms Release time at Unom without parallel diode, typ. 4 ms Bounce time, typ. 3 ms Maximum switching rate without load 20 operations/s Ambient temperature according to DIN IEC 61810-1 or VDE 0435 Part 201 150/200 mW nominal power consumption 400 mW nominal power consumption 500 mW nominal power consumption -25 °C ... +85 °C -25 °C ... +70 °C -25 °C ... +60 °C Thermal resistance approx. 100 K/W Maximum permissible coil temperature 105 °C Vibration resistance, 10 to 55 Hz according to IEC 60068-2-6 55 to 500 Hz according to IEC 60068-2-6 function:10 g damage: 20 g Shock resistance, half sinus, 11 ms according to IEC 68068-2-27 function:10 g damage: 40 g Degree of protection according to VDE 0470 Part 1 EN 60529 / IEC 60529 Capacitance at 1 kHz, 100 VAC between open contacts between closed contacts between contact and coil Electrical endurance at resistive load 6 VDC / 100 mA 30 VDC / 1 A 30 VDC / 2 A (only 400 and 500 mW coils) 230 VAC / 500 mA Mechanical endurance Mounting position Processing information Weight immersion cleanable, IP 67 < 2 pF < 1.5 pF < 5 pF > 2 x 106 operations approx. 5 x 105 operations approx. 1 x 105 operations > 3 x 105 operations 15 x 106 operations any Ultrasonic cleaning is not recommended approx. 6 g Insulation Insulation resistance at 500 V Dielectric test voltage (1 min) contact/winding changeover contact/changeover contact at open contact Surge voltage resistance according to FCC 68 (10/160 µs) 6 ≥ 1000 MΩ 1000 VACrms / 1500 VDC 750 VACrms / 1000 VDC 750 VACrms / 1000 VDC 1500 V Siemens Electromechanical Components Small Relay D2 neutral Ordering code V 2 3 1 0 5 A 5 A 2 0 1 Identification of the small relay D2 neutral Version 0 = 150 mW nominal power consumption 3 = 200 mW 4 = 400 mW 5 = 500 mW Coil number 08 = 3 V nominal voltage (only coils with 150/200 mW nominal power consumption*) 01 = 5 V nominal voltage 02 = 6 V 06 = 9 V 04 = 10 V (only coil with 500 mW nominal power consumption) 03 = 12 V 05 = 24 V 07 = 48 V (not coil with 150 mW nominal power consumption) BT 47 versions 475 = 5 V nominal voltage 479 = 10 V 476 = 12 V 477 = 24 V 478 = 48 V Contact assembly / material A201 = 2 changeover contacts, silver nickel, gold-plated, against silver nickel, gold-plated *) Coils with 400/500 mW nominal power consumption on request Ordering example: V23105-A5301-A201 Small relay D2 neutral, coil 5 V nominal voltage, 200 mW nominal power consumption, Contact material silver nickel, gold-plated, against silver nickel, gold-plated Siemens Electromechanical Components 7