ETC ACT8600-C

ACT8600 – Rad Hard Dual Adjustable
Positive & Negative Voltage
Regulator
COMMON FEATURES
POSITIVE FEATURES
■ Radiation 50K Total Dose
■ Output voltage adjustable
NEGATIVE FEATURES
■ Load regulation 0.1% typ
■ Ripple rejection 80dB typ
from 1.2V to 37V
■ Load regulation 0.3% typ
■ Ripple rejection 77dB typ
C
X LA
ISO
9001
E
I NC .
■
www.aeroflex.com
LE
S
■
CIRCUIT TECHNOLOGY
F
B
■
■
■
independent
Line regulation .01% typ
Output short circuit protected
Packaging – Hermetic Metal
• 6 Leads, .65" x .42" x .200"
Power Package
Industrial , Military and Space
Temperature Range
DESC SMD – TBD
A E RO
■ 1.5A output current
■ Current limit temperature
RT IFIE D
General Description
Aeroflex’s ACT8600 is a radiation hardened, Dual adjustable 6-terminal device containing a
positive (LM117) and a negative (LM137) voltage regulator each capable of supplying in excess of
1.5A over an output voltage range of 1.2V to 37V. Each regulator is exceptionally easy to set-up,
requiring only 2 external resistors to set the output voltage. The module design has been optimized
for excellent regulation and low thermal transients. There is full electrical isolation between positive
and negative regulators and each to the package.
Further, the ACT8600 features internal current limiting, thermal shutdown and safe-area
compensation, making them virtually blowout-proof against overloads. The ACT8600 serves a
wide variety of applications including local on-card regulation, programmable output voltage
regulation or precision current regulation.
The ACT8600 has been specifically designed to meet exposure to radiation environments. It is
available in a 6 lead Metal Power Package. It is guaranteed operational from -55°C to +125°C.
Available screened to MIL-STD-883, the ACT8600 is ideal for demanding industrial, military and
space applications.
1
4
1
ADJ
2
3
1
ADJ
VOUT
VOUT
LM117
VIN
2
2
6
LM137
VIN
3
3
5
Block Diagram / Schematic
eroflex Circuit Technology – Voltage Regulator Modules For The Future © SCD8600 REV B 2/8/02
Absolute Maximum Ratings
Parameter
Power Dissipation (PD)
Operating (Junction) Temperature Range
Lead Temperature (soldering, 10 sec)
Storage Temperature Range
Input-Output Voltage Differential
Thermal Resistance (junction to case ΘJC)
ESD Rating
Range
Units
20
-55 to +150
300
-65 to +150
40
5
2
W
°C
°C
°C
V
°C/W
KV
NOTICE: Stresses above those listed under "Absolute Maximums Rating" may cause permanent damage to the device. These are stress
rating only; functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation
Conditions" may effect device reliability.
Recommended Operating Conditions
Parameter
Range
Units
Output Voltage Range
Positive Voltage Regulator
Negative Voltage Regulator
1.2 to 37
-1.2 to -37
V dc
V dc
Ambient Operating Temperature Range
-55 to +125
°C
4.25 to 41.25
-4.25 to -41.25
V dc
V dc
Input Voltage Range
Positive Voltage Regulator
Negative Voltage Regulator
Positive Regulator
Electrical Performance Characteristics
(TA = -55°C to +125°C, IL = 8mA, Unless otherwise specified)
Parameter
Sym
Reference Voltage
VREF
Line Regulation
Load Regulation 1/
Thermal Regulation
RLINE
RLOAD
VRTH
Conditions
Min
Max
Units
VDIF = 3.0V, TA = + 25°C
1.2
1.3
V
VDIF = 3.3V
1.2
1.3
V
VDIF = 40V
1.2
1.3
V
3.0V < VDIF < 40V, VOUT = VREF, TA = + 25°C
-
±9
mV
3.3V < VDIF < 40V, VOUT = VREF
-
±23
mV
VDIF = 3.0V, 10mA < IL < 1.5A, TA = + 25°C
-
±15
mV
VDIF = 3.3V, 10mA < IL < 1.5A
-
±15
mV
VDIF = 40V, 10mA < IL < 300mA, TA = + 25°C
-
±15
mV
VDIF = 40V, 10mA < IL < 195mA
-
±15
mV
VIN = +14.6V, IL = 300mA, t = 20ms, PD = 20W,
TA = + 25°C
-
±16
mV
66
-
dB
Ripple Rejection
RN
f = 120Hz, CADJ = 10µF, VOUT = VREF 2/
Adjustment Pin Current
IADJ
VDIF = 3.0V, TA = + 25°C
-
100
µA
VDIF = 3.3V
-
100
µA
VDIF = 40V
-
100
µA
VDIF = 3.0V, 10mA < IL < 1.5A, TA = + 25°C
-
±5
µA
VDIF = 3.3V, 10mA < IL < 1.5A
-
±5
µA
VDIF = 40V, 10mA < IL < 300mA, TA = + 25°C
-
±5
µA
VDIF = 40V, 10mA < IL < 195mA
-
±5
µA
Adjustment Pin Current
Change
Aeroflex Circuit Technology
∆IADJ
2
SCD8600 REV B 2/8/02 Plainview NY (516) 694-6700
Positive Regulator
Electrical Performance Characteristics (con’t)
(TA = -55°C to +125°C, IL = 8mA, Unless otherwise specified)
Parameter
Sym
Conditions
Adjustment Pin Current
Change con’t
∆IADJ
Minimum Load Current
ILMIN
Current Limit 2/
ICL
Min
Max
Units
3V < VDIFF < 40V, TA = + 25°C
-
±5
µA
3.3V < VDIFF < 40V
-
±5
µA
VDIF = 3.0V, VOUT = 1.4 (forced), TA = + 25°C
-
5
mA
VDIF = 3.3V, VOUT = 1.4 (forced)
-
5
mA
VDIF = 40V, VOUT = 1.4 (forced)
-
5
mA
VDIF = 15V
1.5
3.5
A
VDIF = 40V, TA = + 25°C
0.18
1.5
A
Notes:
1/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to heating
effects are covered under the specification for thermal regulation. With exception of cases U and 2, all output measurements are referenced
to the case. Measurements taken at the output lead must be adjusted for lead resistance.
2/ If not tested, shall be guaranteed to the specified limits.
Negative Regulator
Electrical Performance Characteristics
(TA = -55°C to +125°C, IL = 8mA, Unless otherwise specified)
Parameter
Sym
Reference Voltage
VREF
Conditions
Min
Max
-1.275
-1.225
V
-1.3
-1.2
V
-1.275
-1.225
V
-1.3
-1.2
V
3.0V < VDIF < 40V, VOUT = VREF, TA = + 25°C
-
±9
mV
3.0V < VDIF < 40V, VOUT = VREF
-
±23
mV
VDIF = 12V, 8mA < IL < 1.5A, TA = + 25°C
-
±25
mV
VDIF = 5V, 8mA < IL < 1.5A
-
±25
mV
VDIF = 3.0V, TA = + 25°C
VDIF = 3.0V
VDIF = 40V, TA = + 25°C
VDIF = 40V
Line Regulation
Load Regulation 1/
Thermal Regulation
RLINE
RLOAD
VRTH
Units
VDIF = 40V, 8mA < IL < 200mA, TA = + 25°C
-
±25
mV
VDIF = 40V, 8mA < IL < 100mA
-
±25
mV
VIN = -14.6V, IL = 1.5A, t = 10ms, PD = 20W,
TA = + 25°C
-
±5
mV
66
-
dB
Ripple Rejection
RN
f = 120Hz, CADJ = 10µF, VOUT = VREF 2/
Adjustment Pin Current
IADJ
VDIF = 3.0V
-
100
µA
VDIF = 40V
-
100
µA
∆IADJ (Line)
3.0V < VDIF < 40V
-
±5
µA
∆IADJ (Load)
VDIF = 5.0V, 8mA < IL < 1.5A
-
±5
µA
VDIF = 3.0V, VOUT = -1.4 (forced)
-
3
mA
VDIF = 10V, VOUT = 1.4 (forced)
-
3
mA
VDIF = 40V, VOUT = 1.4 (forced)
-
5
mA
VDIF = 5V
1.5
3.5
A
VDIF = 40V, TA = + 25°C
0.24
1.2
A
Adjustment Pin Current
Change
Minimum Load Current
Current Limit 2/
ILMIN
ICL
Notes:
1/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to heating
effects are covered under the specification for thermal regulation. With exception of cases U and 2, all output measurements are referenced
to the case. Measurements taken at the output lead must be adjusted for lead resistance.
2/ If not tested, shall be guaranteed to the specified limits.
Aeroflex Circuit Technology
3
SCD8600 REV B 2/8/02 Plainview NY (516) 694-6700
Package Outline — Power Package
.200
.100
.110
.118
ø .010
.150 REF.
CBA
ø.102
M
.420
.407
.210
.2035
ESD/PIN 1
IDENT
–C–
±.020
.720
MEASURED
.LEAD TIP
.420
R.020 TYP.
4 PLCS
.650
–B–
±.003
.109 ±.007
ø .010
.200 MAX.
±.005
–A–
2° MAX. TYP.
±.002
.030
BCA
±.002
.040 DIA.
NOTE: 1. Dimension Tolerance: ±.005 inches
Aeroflex Circuit Technology
4
SCD8600 REV B 2/8/02 Plainview NY (516) 694-6700
CIRCUIT TECHNOLOGY
Ordering Information
Model Number
Screening
DESC SMD #
Package
ACT8600- S
Military Temperature, -55°C to +125°C,
Screened to the individual test methods of MIL-STD-883 IAW
MIL-PRF-38534 Class K
-
6 Lead
Power Pkg
ACT8600
Military Temperature, -55°C to +125°C,
Screened to the individual test methods of MIL-STD-883 IAW
MIL-PRF-38534 Class H
-
ACT8600- 7
Commercial Flow, +25°C testing only
NA
ACT8600- T
Commercial Flow, -55°C to +125°C testing only
ACT8600- I
Commercial Flow, -40°C to +85°C testing only
ACT8600- C
Commercial Flow, -0°C to +70°C testing only
Specifications subject to change without notice
Aeroflex Circuit Technology
35 South Service Road
Plainview New York 11803
www.aeroflex.com
Aeroflex Circuit Technology
Telephone: (516) 694-6700
FAX:
(516) 694-6715
Toll Free Inquiries: (800) THE-1553
E-Mail: [email protected]
5
SCD8600 REV B 2/8/02
Plainview NY (516) 694-6700