ETC RE6050AA16

Solid State Relays
Industrial, 1-Phase Analog Switching
Types RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
• AC Solid State Relay
• Analog switching for resistive load
applications
• 4 to 20 mA control current
• Rated operational current: 10, 25 and 50 AACrms
• Rated operational voltage: Up to 600 VACrms
• LED-indication of loop current
Product Description
Ordering Key
The analog switching relay
works in accordance with the
phase control principle, i.e.
the output switching point in
the AC sine wave depends on
the control current. 4 to 20
mA corresponds to no switch-
Solid State Relay
Switching mode
Rated operational voltage
Rated operational current
4 to 20 mA control current
Non-rep. off-state peak voltage
ing and to full sine wave (near
linear). The relay switches off
every time the current crosses
zero, and switches ON in accordance with the applied
control current.
RE 48 50 AA 12
Type Selection
Switching mode
Rated operational
voltage
Rated operational
current
Control current
Non-rep. voltage
E: Analog switching
24: 115 VACrms
230 VACrms
48: 400 VACrms
480 VACrms
60: 600 VACrms
10: 10 AACrms
25: 25 AACrms
50: 50 AACrms
AA: 4 to 20 mA
06: 650 Vp
12: 1200 Vp
16: 1600 Vp
Selection Guide
Rated operational Non-rep. voltage
voltage
Control current
Rated operational current
10 AACrms
25 AACrms
50 AACrms
115 VACrms
650 Vp
230 VACrms
650 Vp
4 to 20 mA
RE 2410 AA 06
RE 2425 AA 06
RE 2450 AA 06
4 to 20 mA
RE 2410 AA 06
RE 2425 AA 06
RE 2450 AA 06
400 VACrms
480 VACrms
1200 Vp
4 to 20 mA
RE 4810 AA 12
RE 4825 AA 12
RE 4850 AA 12
1200 Vp
4 to 20 mA
RE 4810 AA 12
RE 4825 AA 12
RE 4850 AA 12
600 VACrms
1600 Vp
4 to 20 mA
-
-
RE 6050 AA 16
General Specifications
Operational voltage range
Non-rep. peak voltage
Operational frequency range
Power factor
Approvals
CE-marking
RE 24.. AA 06
RE 48.. AA 12
RE 6050 AA 16
90 to 280 VACrms
≥ 600 Vp
45 to 65 Hz
0.5
UL, CSA
Yes
265 to 530 VACrms
≥ 1200 Vp
45 to 65 Hz
0.5
UL, CSA
Yes
330 to 660 VACrms
≥ 1600 Vp
45 to 65 Hz
0.5
UL, CSA
Yes
Specifications are subject to change without notice (30.06.1999)
1
RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
Input Specifications
Control current range
Voltage drop
Dynamic impedance
Allowable input current
Reverse polarity protected
Insulation
4 to 20 mA
≤ 8 VDC @ 20 mA
≥ 100 Ω
≤ 50 mA
Yes
Rated insulation voltage
Input to output
Rated insulation voltage
Output to case
Insulation resistance
Input to output
Insulation resistance
Output to case
Insulation capacitance
Input to output
Insulation capacitance
Output to case
Caution:
Current to input must be
limited to max. 50 mA.
≥ 4000 VACrms
≥ 4000 VACrms
≥ 1010 Ω
≥ 1010 Ω
≤ 8 pF
≤ 50 pF
Output Specifications
Rated operational current AC 1
Minimum operational current
Rep. overload current t=1 s
Off-state leakage current
@ rated voltage and frequency*)
I2t for fusing t = 1-10 ms
Critical dI/dt
Critical dV/dt commutating
Critical dV/dt off-state
RE ..10 AA ..
RE ..25 AA ..
RE ..50 AA ..
RE 6050 AA 16
10 Arms
500 mArms
< 35 AACrms
25 Arms
500 mArms
55 AACrms
50 Arms
500 mArms
125 AACrms
50 Arms
500 mArms
125 AACrms
< 6 mA
≤ 130 A2s
≥ 100 A/µs
≥ 500 V/µs
≥ 500 V/µs
< 6 mA
≤ 310 A2s
≥ 100 A/µs
≥ 500 V/µs
≥ 500 V/µs
< 6 mA
≤ 1800 A2s
≥ 100 A/µs
≥ 500 V/µs
≥ 500 V/µs
< 6 mA
≤ 1800 A2s
≥ 100 A/µs
≥ 500 V/µs
≥ 500 V/µs
*) Min. power let-through ≥ 0.5%. Please refer to Applications.
Thermal Specifications
Operating temperature
Storage temperature
Junction temperature
Rth junction to case
Rth junction to ambient
RE ..10 AA ..
RE ..25 AA ..
RE ..50 AA ..
-20° to +70°C (-4° to +158°F)
-40° to +100°C (-40° to +212°F)
≤ 125°C (257°F)
≤ 2 K/W
≤ 12.5 K/W
-20° to +70°C (-4° to +158°F)
-40° to +100°C (-40° to +212°F)
≤ 125°C (257°F)
≤ 1.25 K/W
≤ 12 K/W
-20° to +70°C (-4° to +158°F)
-40° to +100°C (-40° to +212°F)
≤ 125°C (257°F)
≤ 0.65 K/W
≤ 12 K/W
Wiring Diagram
Functional Diagram
Mains input/load output
Control
input
IC
Line/load
Control
input
Load output/mains input
2
Specifications are subject to change without notice (30.06.1999)
RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
Heatsink Dimensions
(load current versus ambient temperature)
With the output fully on (360° conduction angle)
RE ..10 AA ..
RE ..25 AA ..
Load
current [A]
Thermal resistance
[K/W]
16
2.7
2.2
1.8
1.3
0.87
0.41
22
25
15
3.1
2.6
2.1
1.7
1.2
0.65
20
14
3.7
3,1
2.6
2
1.5
0.92
13
4.3
3.7
3.1
2.5
1.9
12
5
4.3
3.7
3
11
5.9
5.1
4.4
10
6.9
6
9
7.9
7
5
Power
dissipation [W]
Thermal resistance
[K/W]
Load
current [A]
Power
dissipation [W]
2
1.7
1.4
1
0.71
0.40
32
22.5
2.5
2.1
1.8
1.4
1
0.66
27
18
20
3.1
2.7
2.3
1.9
1.4
1
23
1.2
16
17.5
4
3.5
3
2.5
2
1.4
20
2.3
1.6
15
15
4.9
4.3
3.7
3.1
2.5
1.9
16
3.6
2.8
2.1
13
12.5
6.2
5.4
4.6
3.9
3.1
2.3
13
5.2
4.3
3.5
2.6
12
10
8.1
7.1
6.1
5.1
4
3
10
6.9
5.9
4.9
4
3
10
7.5
11.3
9.9
8.5
7.1
5.6
4.2
7
10.8
9.5
8.1
6.8
5.4
4.1
7
5
-
15.6
13.3
11.1
8.9
6.7
5
-
14.2
12.2
10.2
8.1
6.1
5
2.5
2
3
-
1
-
-
-
14.6
10.9
-
-
-
-
-
-
20
30
40
50
60
70
3
-
-
-
-
18.7
14
20
30
40
50
60
70
TA
Ambient temp. [°C]
1
TA
Ambient temp. [°C]
Heatsink Selection
RE ..50 AA ..
Load
current [A]
Power
dissipation [W]
Thermal resistance
[K/W]
50
0.92
0.76
0.60
0.45
0.29
-
63
45
1.2
0.99
0.80
0.62
0.44
0.26
55
40
1.5
1.3
1.1
0.85
0.63
0.42
47
35
1.9
1.6
1.4
1.1
0.89
0.63
40
30
2.4
2.1
1.8
1.5
1.2
0.91
33
25
3
2.7
2.3
1.9
1.5
1.1
26
20
3.9
3.5
3
2.5
2
1.5
20
15
5.5
4.8
4.1
3.4
2.7
2.1
15
10
8.6
7.5
6.4
5.4
4.3
3.2
9
5
17.9
15.6
13.4
11.2
8,9
6.7
4
20
30
40
50
60
70
Carlo Gavazzi Heatsink
(see Accessories)
No heatsink required
RHS 100 Assy
RHS 301 Assy
RHS 301 F Assy
Consult your distributor
Thermal resistance
Rth s-a > 12.5
3.0
0.8
0.25
< 0.25
K/W
K/W
K/W
K/W
K/W
Compare the value found in the current versus temperature
chart with the standard heatsink values and select the heatsink with the next lower value.
TA
Ambient temp. [°C]
Specifications are subject to change without notice (30.06.1999)
3
RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
Applications
This relay is suitable for temperature control or control of
lighting.
The relay can also be used for
soft turn-on of high-power incandescent lamps.
Iin
Transfer characteristics
Output power as a function of control input (4 to 20 mA)
Iin [mA]
Pout [%]
typically 50/60 Hz
4
6
8
10
12
14
16
18
20
25
0.5
8
22
40
54
66
75
81
86
92
Uline
L
4 to
20 mA
Load
F
C
Max. unit variation:
Temperature variation:
L: Optional radio interference low-pass filter component
RE 24.. AA 06 UL = 230 V
RE 48.. AA 12 UL = 480 V
RE 6050 AA 16 UL = 600 V
C: Optional radio interference low-pass filter component
Application hints:
L and C must be connected
as close as possible to the
SSR.
Dimensions
***
***
***
***
***
4
Accessories
Protection cover
Heatsinks
DIN rail adapter
Varistors
Fuses
For further information refer
to "General Accessories".
Housing Specifications
**
** = ± 0.4 mm
*** = ± 0.5 mm
± 5% @ Tj = 25°C
± 5% @ Tj = -20° to + 125°C
Weight
Housing material
Base plate
Potting compound
Relay
Mounting screws
Mounting torque
Control terminal
Mounting screws
Mounting torque
Power terminal
Mounting screws
Mounting torque
Approx. 110 g
Noryl GFN 1, black
Aluminium
Polyurethane
M5
≤ 1.5 Nm
M3 x 6
≤ 0.5 Nm
M5 x 6
≤ 2.4 Nm
*** **
Specifications are subject to change without notice (30.06.1999)