ETC RA2410-D06T

Solid State Relays
Industrial, 1-Phase ZS
Types RA 24.. -D 06 T, RA 24.. -D 06 TF
• AC Solid State Relay
• Zero switching
• Low-cost triac type
• Rated operational current: 10 and 25 AACrms
• Non-repetitive voltage: Up to 650 Vp
• Rated operational voltage: 230 VACrms
• Input ranges: 3 to 32 VDC
• Insulation: OPTO (input-output) 4000 VACrms
• Fast-on version available
Product Description
Ordering Key
The triac version of the zero
switching relay is an inexpensive solution for resistive
loads. The zero switching re-
Solid State Relay
Switching mode
Rated operational voltage
Rated operational current
Control voltage
Non-rep. peak voltage
Output
lay switches ON when the AC
sine curve just crosses zero,
and switches OFF when the
current crosses zero.
RA 24 10 -D 06 T
Type Selection
Switching mode
Rated operational voltage
Rated operational Control voltage
current
Non-rep. voltage
Output
A: Zero switching
24: 230 VACrms
10: 10 AACrms
25: 25 AACrms
-D: 3 to 32 VDC
06: 650 Vp
T: Triac
TF: Triac/Fast-on
terminals
Rated operational Non-rep. voltage
voltage
Terminal
type
Control voltage
Rated operational current
10 AACrms
25 AACrms
230 VACrms
650 Vp
Rivet terminals
3 to 32 VDC
RA 2410 -D 06T
RA 2425 -D 06T
230 VACrms
650 Vp
Fast-on terminals
3 to 32 VDC
RA 2410 -D 06TF
RA 2425 -D 06TF
Selection Guide
General Specifications
Insulation
Operational voltage range
Non-rep. peak voltage
Operational frequency range
Power factor
Approvals
CE-marking
Rated insulation voltage
Input to output
Rated insulation voltage
Output to case
Insulation resistance
Input to output
Insulation resistance
Output to case
Insulation capacitance
Input to output
Insulation capacitance
Output to case
24 to 280 VACrms
≥ 650 Vp
45 to 65 Hz
≥ 0.5 @ 230 VACrms
CSA, UL
Yes
Specifications are subject to change without notice (30.06.1999)
≥ 4000 VACrms
≥ 4000 VACrms
≥ 1010 W
≥ 1010 W
≤ 8 pF
≤ 25 pF
1
RA 24.. -D 06 T, RA 24.. -D 06 TF
Input Specifications
RA 24 .. -D 06T/TF
Control voltage range
Pick-up voltage
Drop-out voltage
Reverse voltage
Input impedance
Response time pick-up
Response time drop-out
3 to 32 VDC
≤3V
≥1V
≤ 32 VDC
1.5 kW
≤ 1/2 cycle
≤ 1/2 cycle
Output Specifications
Rated operational current AC 1
Minimum operational current
Rep. overload current t=1 s
Non-rep. surge current t=20 ms
Off-state leakage current
@ rated voltage and frequency
I2t for fusing t=1-10 ms
Critical dI/dt
On-state voltage drop
@ rated current
Critical dV/dt commutating
Critical dV/dt off-state
RA 2410 -D 06 T/F
RA 2425 -D 06 T/F
10 Arms
20 mArms
≤ 30 Ap
90 Ap
25 Arms
20 mArms
≤ 50 Ap
200 Ap
≤ 5 mArms
≤ 40 A2s
≥ 10 A/µs
≤ 5 mArms
≤ 200 A2s
≥ 10 A/µs
≤ 1.6 Vrms
≥ 10 V/µs
≥ 250 V/µs
≤ 1.6 Vrms
≥ 10 V/µs
≥ 250 V/µs
Thermal Specifications
Operating temperature
Storage temperature
Junction temperature
Rth junction to case
Rth junction to ambient
RA 2410 -D 06 T/TF
RA 2425 -D 06 T/TF
-20° to +70°C (-4° to +158°F)
-40° to +100°C (-40° to +212°F)
≤ 125°C (≤ 257°F)
≤ 2.5 K/W
≤ 12.5 K/W
-20° to +70°C (-4° to +158°F)
-40° to +100°C (-40° to +212°F)
≤ 125°C (≤ 257°F)
≤ 1.8 K/W
≤ 12.5 K/W
Wiring Diagram
Functional Diagram
Mains input/load output
Control
input
Line/load
Control
input
Load output/mains input
2
Specifications are subject to change without notice (30.06.1999)
RA 2410 .. 06 T, RA 24.. -D 06 TF
Heatsink Dimensions
(load current versus ambient temperature)
RA 24 10 .. .. T/F
Load
current [A]
RA 24 25 .. .. T/F
Thermal resistance
[K/W]
Power dissipation [W]
Thermal resistance
[K/W]
Load
current [A]
Power dissipation [W]
10
6.5
5.6
4.7
3.9
3
2.1
12
25
1.4
1.1
0.77
0.45
-
-
32
9
7.8
6.8
5.8
4.8
3.8
2.8
10
23
1.9
1.5
1.2
0.79
0.43
-
28
8
9.2
8
6.9
5.7
4.6
3.4
9
20
2.5
2.1
1.6
1.2
0.81
0.39
24
7
10.8
9.5
8.1
6.8
5.4
4.1
7
18
3.3
2.8
2.3
1.8
1.3
0.8
20
6
-
11.4
9.8
8.2
6.5
4.9
6
15
4.3
3.7
3.1
2.5
2
1.4
17
5
-
-
12.2
10.2
8.1
6.1
5
13
5.8
5.1
4.4
3.6
2.8
2.2
14
4
-
-
-
-
10.5
7.9
4
10
7.6
6.7
5.7
4.8
3.8
2.9
11
3
-
-
-
-
-
10.9
3
8
10.5
9.2
7.9
6.6
5.3
4
8
2
-
-
-
-
-
-
2
5
-
14.4
12.3
10.3
8.2
6.2
5
1
-
-
-
-
-
-
1
3
3
20
30
40
50
60
70
TA
-
-
-
-
17.1
12.8
20
30
40
50
60
70
Ambient temp. [°C]
Ambient temp. [°C]
Dimensions
Heatsink Selection
Rth s-a > 12.5
3.0
0.8
0.25
< 0.25
K/W
K/W
K/W
K/W
K/W
**
***
***
No heatsink required
RHS 100 Assy
RHS 301 Assy
RHS 301 F Assy
Consult your distributor
Thermal resistance
***
***
Carlo Gavazzi Heatsink
(see Accessories)
TA
Compare the value found in the current versus temperature
chart with the standard heatsink values and select the heatsink with the next lower value.
** = ± 0.4 mm
*** = ± 0.5 mm
Housing Specifications
Accessories
Protection cover
Heatsinks
DIN rail adapter
Varistors
Fuses
For further information refer
to "General Accessories".
Terminals RA 24.. -D 06 TF
Control terminal (Fast-on)
Power terminal (Fast-on)
**
6.3 x 0.8 mm
6.3 x 0.8 mm
Specifications are subject to change without notice (30.06.1999)
Weight
Housing material
Base plate
Potting compound
Relay
Mounting screws
Mounting torque
Control terminal
Mounting screws/Fast-on
Mounting torque
Power terminal
Mounting screws/Fast-on
Mounting torque
Approx. 110 g
Noryl GFN 1, black
Aluminium
Polyurethane
M5
≤ 1.5 Nm
M3 x 6/6.3 x 0.8 mm
≤ 0.5 Nm
M5 x 6/6.3 x 0.8 mm
≤ 2.4 Nm
3