ETC DS1836B-10

DS1836/A/B/C/D
3.3V/5V MicroManager
www.dalsemi.com
FEATURES
5V or 3.3V power-on reset
True 3V operation power switch
Switches to battery at 3.8V (2.6V for 3.3V
versions)
Excellent for systems designed to operate
with dual power supplies
Asserts resets during power transients
Maintains reset for 350 ms after VCC returns
to an in-tolerance condition
Reduces need for discrete components
Precision temperature-compensated voltage
reference and voltage sensor
8-pin DIP or space saving 8-pin SOIC surface
mount available
CMOS reset output for low current operation
Operating temperature of -40°C to +85°C
Perfect for PIC microprocessor applications
PIN ASSIGNMENT
VCC
1
8
RST(*RST)
VBAT
2
7
NMI
NC
3
6
IN
VOUT
4
5
GND
8-Pin DIP (300-mil)
VCC
1
8
RST(*RST)
VBAT
2
7
NMI
NC
3
6
IN
VOUT
4
5
GND
8-Pin SOIC (150-mil)
DS1836A/C (*DS1836B/D)
PIN DESCRIPTION
VCC
VBAT
NC
VOUT
GND
IN
NMI
RST (*RST)
- Power Supply Input
- Battery Supply Input
- No Connect
- Power Supply Output
- Ground
- Sense Input
- Non-maskable Interrupt
- Reset Output
DESCRIPTION
The DS1836 MicroManager performs three vital system functions. First a precision temperaturecompensated reference and comparator circuit monitor the status of the voltage on VCC and when an outof-tolerance condition is detected, an internal power-fail signal is generated which forces the reset active.
If VCC continues to degrade it switches to the battery supply when VCC drops below 3.8 volts (2.6 volts
for 3.3-volt versions). When VCC exceeds 3.9 volts (2.8 volts for 3.3-volt versions); VOUT will again be
supplied from VCC. Reset will remain active for 350 ms after VCC returns to an in-tolerance condition.
Lastly, the DS1836 supports a sense input that sends a non-maskable interrupt whenever the sense input
drops below 1.25 volts.
1 of 9
071700
DS1836A/B/C/D
OPERATION
Power Monitor
The DS1836 provides the functions of detecting out-of-tolerance conditions on a 3.3-volt or 5-volt power
supply and warning a processor-based system of impending power failure. When VCC is detected as out of
tolerance the RST will be forced active. When VCC returns to a valid state the RST will remain active for
about 350 ms and then return to an inactive state until the next VCC out-of-tolerance condition.
On power-up reset is kept active for approximately 350 ms after the power supply input has reached the
selected tolerance. This allows the power supply and system power to stabilize before RST is released.
Power Switch (DS1836A & B)
The DS1836 switches the VOUT output between VCC and VBAT. On the initial power-up VOUT draws
current from the VBAT input until VCC exceeds 3.9 volts. When VCC exceeds 3.9 volts VOUT switches from
VBAT to VCC and will not switch back to VBAT until VCC drops below 3.8 volts. When VCC is below 3.8
volts, power will be drawn from the supply with the highest voltage, either VCC or VBAT.
Power Switch (DS1836C & D)
The DS1836 switches the VOUT output between VCC and VBAT. On the initial power up VOUT draws
current from the VBAT input until VCC exceeds 2.8 volts. When VCC exceeds 2.8 volts VOUT switches from
VBAT to VCC and will not switch back to VBAT until VCC drops below 2.6 volts. When VCC is below 2.6
volts, power will be drawn from the supply with the highest voltage either VCC or VBAT.
BLOCK DIAGRAM Figure 1
* DS1836B and DS1836D
2 of 9
DS1836A/B/C/D
Non-Maskable Interrupt
The DS1836 generates a non-maskable interrupt ( NMI ) for early warning of a power failure. A precision
comparator monitors the voltage level at the IN pin relative to an on-chip reference generated by an
internal band gap. The IN pin is a high impedance input allowing for a user-defined sense point. An
external resistor voltage divider network (Figure 3) is used to interface with high voltage signals. This
sense point may be derived from a regulated supply or from a higher DC voltage level closer to the main
system power input. Since the IN trip point VTP is 1.25 volts, the proper values for R1 and R2 can be
determined by the equation as shown in Figure 3. Proper operation of the DS1836 requires that the
maximum voltage at the IN pin be limited to the active supply (VCC or VBAT). Therefore, the maximum
allowable voltage at the supply being monitored (VMAX) can also be derived as shown in Figure 3. A
simple approach to solving the equation is to select a value for R2 high enough to keep power
consumption low, and solve for R1. The flexibility of the IN input pin allows for detection of power loss
at the earliest point in a power supply system, maximizing the amount of time for system shutdown
between NMI and RST (or RST ).
A pull-up resistor is required for proper operation of the NMI open-drain output. A 10 kΩ=resistor would
be a typical value for the pull-up resistor.
TYPICAL APPLICATION Figure 2
3 of 9
DS1836A/B/C/D
NON-MASKABLE INTERRUPT CIRCUIT EXAMPLE Figure 3
VSENSE =
R1 + R2
x 1.25
R2
Example:
VSENSE = 4.50V at the trip point
100 kΩ = R2
Therefore:
4.5 =
R1 + 100k
x 1.25
100k
R1 = 260 kΩ
TIMING DIAGRAM: NON-MASKABLE INTERRUPT Figure 4
4 of 9
DS1836A/B/C/D
OUTPUT VALID CONDITIONS
The DS1836 can maintain valid outputs as long as one input remains above 1.2 volts. However, the RST
outputs on the DS1836A (or C) use a push-pull output structure which can maintain a valid output below
1.2 volts on an input. To sink current below 1.2 volts a resistor can be connected from RST to GND (see
Figure 5). This arrangement will maintain a valid value on the RST outputs even if all supply inputs are
at 0 volts. During conditions when the RST is in the inactive or high state this arrangement will draw
current through the pull down resistor. A value of about 100 kΩ=should be adequate to maintain a valid
condition.
The DS1836 NMI output requires a pull-up resistor on the output to maintain a valid output. The value of
the resistor is not critical in most cases but must be set low enough to pull the output to a high state. A
common value used is 10 kΩs (see Figure 3).
APPLICATION DIAGRAM:
RST VALID TO 0 VOLTS VCC ON THE DS1836A OR DS1836C Figure 5
TIMING DIAGRAM: POWER-UP Figure 6
5 of 9
DS1836A/B/C/D
TIMING DIAGRAM: POWER-DOWN Figure 7
TIMING DIAGRAM: POWER SWITCH Figure 8
6 of 9
DS1836A/B/C/D
ABSOLUTE MAXIMUM RATINGS*
Voltage on VCC or VBAT Pin Relative to Ground
Voltage on any I/O Pin Relative to Ground**
Operating Temperature
Storage Temperature
Soldering Temperature
-0.5V to +7.0V
-0.5V to VOUT + 0.5V
-40°C to +85°C
-55°C to +125°C
260°C for 10 seconds
*
This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended periods of time may affect reliability.
**
The voltage input on IN can exceed VCC/VBAT if the input current is less than 10 mA.
RECOMMENDED DC OPERATING CONDITIONS
PARAMETER
Supply Voltage
Secondary Supply Voltage
SYMBOL
VCC
MIN
1.2
VBAT
1.2
7 of 9
(-40°C to +85°C)
TYP
MAX
5.5
UNITS
V
NOTES
1
5.5
V
1
DS1836A/B/C/D
DC ELECTRICAL CHARACTERISTICS
PARAMETER
(-40°C to +85°C; VCC=1.2V to 5.5V)
SYMBOL
VOH
MIN
VCC
-0.5
Input Leakage
IIL
-1.0
Output Current @ 2.4V
IOH
Output Current @ 0.4V
IOL
Operating Current @ Ο 5.5VIN
ICC
35
Operating Current @ Ο 3.6VIN
ICC
25
Output Voltage @ -500 µA
TYP
MAX
UNITS
NOTES
V
1
µA
2
µA
3
mA
3
55
µA
4
40
µA
5
VCC
-0.1
+1.0
350
+10
Supply Output Current
ICC01
100
mA
6
Supply Output Current
ICC02
100
mA
7
Supply Output Voltage (VCC)
VOUT
VCC
-0.5
VCC
-0.3
V
1, 8
Supply Output Voltage (VBAT)
VOUT
VBAT
-0.5
VBAT
-0.3
V
1,9
RST VCC Trip Point DS1836A(or B)-05
VCCTP
4.50
4.63
4.75
V
1
RST VCC Trip Point DS1836A(or B)-10
VCCTP
4.25
4.37
4.50
V
1
RST VCC Trip Point DS1836C(or D)-10
VCCTP
2.80
2.88
2.97
V
1
RST VCC Trip Point DS1836C(or D)-20
VCCTP
2.67
2.72
2.80
V
1
Power Supply Trip Points (VCC to VBAT)
DS1836 C or D
VCCFTP
2.60
2.65
2.70
V
1, 10
Power Supply Trip Points (VBAT to VCC)
DS1836 C or D
VCCRTP
2.70
2.75
2.80
V
1, 10
0.10
µA
11
VBAT Leakage Current
ICC03
Power Supply Trip Points (VCC to VBAT)
DS1836 A or B
VCCFTP
3.80
3.85
3.0
V
1, 10
Power Supply Trip Points (VBAT to VCC)
DS1836 A or B
VCCRTP
3.90
3.95
4.0
V
1, 10
IN Input Trip Point
VTP
1.15
1.25
1.35
V
1
Output Capacitance
COUT
10
pF
8 of 9
DS1836A/B/C/D
AC ELECTRICAL CHARACTERISTICS
PARAMETER
SYMBOL
tIPD
VTP to NMI Delay
Reset Active Time
VCC Slew Rate (VINTP(MIN) to VINTP(MAX))
VCC Detect to RST
VCC Slew Rate (VINTP(MAX) to VINTP(MIN))
(-40°C to +85°C; VCC=1.2V to 5.5V)
MIN
tRST
200
tR
0
tRPU
200
tF
300
TYP
350
MAX
1
UNITS
500
ms
NOTES
µs
ns
350
500
ms
12
µs
10
µs
VCC Detect to RST
tRPD
2
VCC to VBAT (VCC falling through 2.6V)
tPSW
1
µs
13
VBAT to VCC (VCC rising through 2.8V)
tRSW
1
µs
13
NOTES:
1. All voltages are referenced to ground.
2. Measured with outputs open and inputs at VCC or GND.
3. Measured with outputs open and VCC or VBAT
2.7V.
4. Measured with outputs open and both VCC and VBAT 5.5V.
5. Measured with outputs open and both VCC and VBAT 3.6V.
6. VOUT = VCC - 0.3V.
7. VOUT = VBAT - 0.3V.
8. VCC
9. VBAT
2.7V.
2.0V and VCC 1.9V.
10. VCCFTP is offset by approximately 0.1V from VCCRTP.
11. VBAT in the off state and VBAT < VCC (VBAT > VCC and VBAT in the off state 1 µA maximum).
12. tR = 5 µs with one supply
2.5V.
13. Typical only; parameter not tested.
DATA SHEET REVISION SUMMARY
The following represent the key differences between 01/17/95 and 06/17/97 version of the
DS1836A/B/C/D data sheet. Please review this summary carefully.
1. Correction to various typos.
2. Change battery switch characteristics for 5V versions.
9 of 9