AC SOLID STATE RELAYS PD1201/PD2401/PD2601 DESCRIPTION The PD1201/PD2401/PD2601 are AC Solid State Switches utilizing dual power SCR outputs. These devices also include zero turn on circuitry and are available with a blocking voltage up to 600V. FEATURES APPLICATIONS ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Load Current up to 1A Blocking Voltage to 600V 5mA Sensitivity Zero-Crossing Detection DC Control, AC Output Optically Isolated TTL and CMOS Compatible Low EMI and RFI Generation High Noise Immunity VDE compatible Machine Insertable, Wave Solderable Programmable Control Process Control Power Control Panels Remote Switching Gas Pump Electronics Contractors Large Relays Solenoids Motors Heaters RATINGS (@ 25˚ C) APPROVALS Parameter ■ UL recognized file #: E69938 ■ CSA certified file #: LR 43639-8 OPTIONS / SUFFIXES ■ S: Surface Mount Package Min Typ Max Units Input Power Dissipation - - 1501 mW Input Control Current Peak (10ms) - - 50 1 mA A Reverse Input Voltage Total Package Dissipation PD - - 5 V - - 16002 mW - 3 - pF 3750 -40 - +85 VRMS ° C -40 - +125 ° C - - +260 +220 ° C C Capacitance Input to Output PD Series Pinout 1 16 – LED + LED Isolation Voltage Input to Output Operational Temperature Storage Temperature Soldering Temperature DIP Package Surface Mount Package (10 Seconds Max.) ZC 1 10 2 AC Load ° Derate Linearly 1.33 mW/˚C Derate Linearly 16.6 mW/˚C 8 AC Load Note: For Mechanical Dimensions See Pages 408-415 www.clare.com 397 AC SOLID STATE RELAYS PD1201/PD2401/PD2601 SPECIFICATIONS PD1201 PARAMETERS CONDITIONS SYMBOL MIN TYP PD2401 PD2601 MAX MIN TYP MAX MIN TYP MAX UNITS Output Characteristics @ 25°C Peak Blocking Voltage - VDRM - - 400 - - 500 - - 600 V Load Current (Continuous) VL=120-240VAC IL 0.005 - 1 0.005 - 1 0.005 - 1 A Off State Leakage Current VDRM ILEAK - - 1 - - 1 - - 1 mA On-State Voltage Drop IL=1A - - 1.2 - - 1.2 - - 1.2 VRMS Critical Rate of Rise dv/dt - V/µS Switching Speeds Turn-on Turn-off Zero-Cross Turn-On Voltage IF=5 mA IF=5 mA 1000 1200 1000 1200 - 1000 1200 - - 0.5 0.5 - - 0.5 0.5 - - 0.5 0.5 Cycles Cycles 1st half cycle Sub. half cycle - 2 - 5 1 - 2 - 5 1 - 2 - 5 1 V V - 20 - 500 20 - 500 20 - 500 Hz Operating Frequency1 TON TOFF - Load Power Factor for Guaranteed Turn-On2 - PF 0.25 - - 0.25 - - 0.25 - - - - IF IF 5 10 - 50 100 5 10 - 50 100 5 10 - 50 100 mA mA IF=5mA VF Input Characteristics @ 25°C Input Control Current For Normal Environment For High Noise Environment Input Voltage Drop 0.9 1.2 1.4 0.9 1.2 1.4 0.9 1.2 1.4 V 0.8 - - 0.8 - - 0.8 - - V IR - - 10 - - 10 - - 10 uA - CI/O - - 3 - - 3 - - 3 VRMS - VI/O 3750 - - 3750 - - 3750 - - VRMS Input Drop-out Voltage - Reverse Input Current VR=5V Input to Output Capacitance Input to Output Isolation Common Characteristics @ 25°C 1 Zero cross 1st 1/2 cycle @ <100Hz 2 Snubber circuits may be required at low power factors. Note: For Mechanical Dimensions See Pages 408-415 North America: 1-800-272-5273 398 Europe: 32-11-300868 Asia: 886-2-2523-6368 Japan: 03-3980-2212 AC SOLID STATE RELAYS PD1201/PD2401/PD2601 PERFORMANCE DATA PD Series Max. Surge Current (Non-Repetitive) Peak Surge Current (A) Load Current (A) 1.0 0.8 RΘJA = 60°C/W 0.6 0.4 0.2 NOTE: Values apply to TJ = 50°C before Surge 20 15 10 5 PD Series Typical Forward Voltage vs. Temperature 2.0 Forward Voltage (V) PD Series Load Current, Free Air 1.2 1.5 1.0 0.5 0 -40 0 55 16 85 50 10 25 50 75 100 125 150 Ambient Temperature (°C) PD Series dv/dt Method PD Series Typical dv/dt vs. Temperature Critical Rate of Rise (V/µs) 100 Pulse Duration (ms) Ambient Temperature (°C) 1200 Vo 1000 800 Vo = 300V dv 0.63 x 300V dt RC 63% 600 189 RC In accordance with EIA/NARM Standards RS-443 for Solid State Relays 400 200 10% 0 25 50 85 RC Ambient Temperature (°C) www.clare.com 399