ETC SRC15ML

PAGE:
SAFETY DATA SHEET
1 of 4
PRINT DATE:
REF:
22/02/1999
SRC-BULK
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE
COMPANY/UNDERTAKING
Product name:
SILICONE REMOVEABLE COATING
Product code:
SRC-BULK
Supplier:
ELECTROLUBE
H.K. Wentworth Ltd.,
Wentworth House, Blakes Road,
Wargrave, Berkshire, RG10 8AW, United Kingdom.
Fax No: 0118 9403084
0118 9404031
Emergency telephone number:
2. COMPOSITION/INFORMATION ON INGREDIENTS
Identification of the preparation
Chemical Name
XYLENE, MIXTURE OF ISOMERS
CAS-No
1330-20-7
EC-No
215-535-7
Class
R10 Xn;
R20/21 Xi;
R38
Weight %
> 30
NON HAZARDOUS CONSTITUENTS
> 30
3. HAZARDS IDENTIFICATION
Most important hazards:
Specific hazards
Flammable and Harmful
Harmful by inhalation and in contact with skin. Irritating to eyes
and skin. In higher concentrations, xylene is irritating to eyes and
the respiratory tract, causes drowsiness and may cause centralnervous effects (headache etc.). Prolonged exposure - Liver and
kidney injuries may occur.
4. FIRST AID MEASURES
General advice:
Inhalation:
Skin contact:
Eye contact:
Ingestion:
Remove from exposure, lie down.
Move to fresh air in case of accidental inhalation of vapours.
Remove immediately adhering matter.
Rinse immediately with plenty of water, also under the eyelids, for at least 15
minutes. If eye irritation persists, consult a specialist.
Immediately give large quantities of water to drink. Consult a physician if
necessary.
5. FIRE-FIGHTING MEASURES
Suitable extinguishing media:
Extinguish with carbon dioxide, dry chemical, foam or waterspray.
Extinguishing media which must Do not use a solid water stream as it may scatter and spread fire.
not be used for safety reasons:
Specific hazards:
Highly flammable. Cool containers / tanks with spray water.
Special protective equipment
In the event of fire, wear self-contained breathing apparatus.
for firefighters:
Specific methods:
Standard procedure for chemical fires.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions:
Environmental precautions:
Use personal protective equipment.
Do not flush into surface water or sanitary sewer system.
Product name:
SILICONE REMOVEABLE
COATING
Methods for cleaning up:
PAGE:
2 of 4
PRINT DATE:
22/02/1999
REF:
SRC-BULK
Soak up with inert absorbent material. Shovel into suitable
container for disposal.
7. HANDLING AND STORAGE
Handling:
Storage:
Use only in area provided with appropriate exhaust ventilation. Avoid contact with the
skin and the eyes. Do not breath vapours or spray mist. When using, do not eat, drink or
smoke.
Keep away from heat and sources of ignition. Keep in a cool, well-ventilated place Store
in a cool and shaded area.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Chemical Name:
National occupational exposure limits:
HSC(EH40)
Long term (8 hrs) = 100ppm / 441mgm-3
Short term (15 min) = 150ppm / 662mgm-3
XYLENE, MIXTURE OF ISOMERS
NON HAZARDOUS CONSTITUENTS
Engineering measures:
Personal protection equipment:
- Respiratory protection:
- Hand protection:
- Eye protection:
- Skin and body protection:
Hygiene measures:
Provide adequate ventilation.
When workers are facing concentrations above the exposure limit
they must use appropriate certified respirators.
Prolonged exposure - solvent-resistant gloves (butylrubber)
goggles / safety glasses with side-shields
not required under normal use.
Wash hands before breaks and immediately after handling the
product. When using, do not eat, drink or smoke.
9. PHYSICAL AND CHEMICAL PROPERTIES
Form:
Colour:
Odour:
Boiling point/range:
Melting point/range:
Flash point:
Autoignition temperature:
Explosion limits:
Vapour pressure:
Relative density:
Bulk density:
Solubility:
Water solubility
Viscosity:
liquid
clear colourless
Benzene
- lower
- upper
( 30 °C)
( 20 °C)
( 20 °C)
* as xylene
n/d
n/d
* 27
* 465
* 1.1
* 7
* 10
>= 0.844
844
°C
°C
°C
°C
vol. %
vol. %
hPa
immiscible
1.6 -2.0
(g/l)
mPa.s
kg/m3
10. STABILITY AND REACTIVITY
Stability:
Conditions to avoid:
Materials to avoid:
Hazardous decomposition products:
Stable under recommended storage conditions.
Keep away from sources of ignition, strong oxidizing agents.
strong oxidizing agents
No decomposition if stored and applied as directed.
11. TOXICOLOGICAL INFORMATION
Acute toxicity:
LD50/oral/rat = 4.3g/kg
SILICONE REMOVEABLE
COATING
Product name:
Local effects:
Sensitization:
PAGE:
3 of 4
PRINT DATE:
22/02/1999
REF:
SRC-BULK
May cause eye or skin irritation with susceptible persons
May cause sensitization by skin contact
In higher concentrations, xylene is irritating to eyes and the
respiratory tract, causes drowsiness and may cause centralnervous effects (headache etc.)
Effects of excessive exposures may include liver toxicity
Long term toxicity:
Chronic toxicity:
12. ECOLOGICAL INFORMATION
Mobility:
Persistence and degradability:
Bioaccumulation:
Ecotoxicity effects:
According to the results of tests of biodegradability this product is
not readily biodegradable.
No data is available on the product itself.
Toxic to aquatic organisms. Xylene LC50/96h/rainbow trout =
2.6-8.4 mg/l
13. DISPOSAL CONSIDERATIONS
Waste from residues / unused products:
Contaminated packaging:
In accordance with local and national regulations
Can be incinerated, when in compliance with the Environment
Protection Act 1990 (Process Guidance Note IPR5/1). Do not
dispose of waste into sewer.
14. TRANSPORT INFORMATION
UN-No:
1263
ADR/RID
Class:
3
Proper shipping name:
Marine pollutant:
No
Item:
3º (b)
HI/UN No:
1263
Paint
IMO
Class:
3.2
EmS:
3-05
Proper shipping name: Paint
ICAO
Class:
3
Proper shipping name
IMDG Page:
MFAG:
3268
310
UN/ID No:
1263
Paint
15. REGULATORY INFORMATION
Classification according to European directive on classification of hazardous preparations 90/492/EEC
- Contains:
Xylene
- Symbol(s):
R-phrase(s):
S-phrase(s):
Xn - Harmful
R10 - Flammable.. R20/21 - Harmful by inhalation and in contact with skin. R38 Irritating to skin.
- Keep in a cool, well-ventilated place. S16 - Keep away from sources of ignition
- No smoking. S25 - Avoid contact with eyes.. S33 - Take precautionary
measures against static discharges..
16. OTHER INFORMATION
Recommended use:
Product name:
SILICONE REMOVEABLE
COATING
PAGE:
4 of 4
PRINT DATE:
22/02/1999
REF:
SRC-BULK
Recommended restrictions:
Revision number:
Further information:
2
CN no 32089010
Contact Name: Carolyn Booth
Department: Technical
The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication The
information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be
considered a warranty or quality specification The information relates only to the specific material designated and may not be valid for such material
used in combination with any other materials or in any process unless specified in the text
Technical Data Sheet
PRODUCT DESCRIPTION:
Silicone Removable Coating
DATE:
03/97
PRODUCT CODE:
SRC
PAGES:
2
PRODUCT DESCRIPTION
SRC is a silicone conformal coating designed to protect printed circuit boards exposed to high humidity
environments. The coating is specially formulated to be easily removed with most common solvents.
Electrolube Ultrasolve (ULS) is ideal.
SRC in bulk may be applied by spraying, dipping or brushing. Thinners are available to maintain the viscosity of the coating. A UV trace is included within the coating to allow easy and reliable post-coating
inspection. The stronger the reflected light, the thicker the coating layer.
CHARACTERISTICS
*
*
*
*
*
*
Good adhesion under high humidity conditions.
Low oxygen permitivity and excellent surface resistivity.
Excellent resistance to mould growth, tropical conditions and ultraviolet light.
Good operating temperature range.
Good dielectric properties, coating thickness typically being 25 microns.
Repairability - easily soldered through without fear of highly toxic gases being produced or totally
removed with Ultrasolve.
APPLICATION
SRC can be sprayed, dipped or brushed. The thickness of the coating depends on the method of application, but a dip coater normally deposits a film thickness of about 25 microns (single coat). Workshop
temperatures of less than 16°C or relative humidities in excess of 75% are unsuitable for the application of
SRC. All PCBs, being composite materials, absorb moisture. If this is not removed, the conformal coating
may not protect to the required extent. Pre-drying or vacuum desiccation, will remove the moisture.
Cleaning
Boards should be thoroughly cleaned before coating. This is required to ensure that satisfactory adhesion to
the substrate is possible. Also all flux residues must be removed as they may become corrosive if left on
the PCB. Electrolube manufacture a range of 100% Ozone Friendly cleaning products. All products
produce results within the Military specification. Please contact Electrolube for further information.
Dip Coating
Electrolube manufacture an automated Dip Coating Machine (DCM) which is ideal for applying all of the
Electrolube Conformal Coatings including SRC. Ensure that the coating material in the container has been
agitated thoroughly and has been allowed to stand for at least 2 hours for all the air bubbles to disperse.
SRC Thinners (DCT) should be used to keep the SRC coating at a suitable viscosity for dipping. DCT is
added periodically as the solvent evaporates. The viscosity should be checked using a viscosity meter or
"flow cup". The board assemblies should be immersed in the SRC dipping tank in the vertical position, or at
an angle as close to the vertical as possible. Connectors should not be immersed in the liquid unless they
are very carefully masked. Electrolube Peelable Coating Mask (PCM) is ideal for this application.
Leave submerged for about 1 minute until the air bubbles have dispersed. The board or boards should then
be withdrawn VERY SLOWLY so that an even film covers the surface. After withdrawing, the boards should
be left to drain over the tank until the majority of residual coating has left the surface.
Cont’d...2
ELECTROLUBE Wentworth House, Blakes Road, Wargrave, Berkshire, RG10 8AW, UK
Telephone: +44(0) 118 940 4031/ 3014 Fax: +44(0) 118 940 3084
ISO 9002 Registered Firm. Certificate No. FM 32082
SRC
-2-
Spraying
Bulk SRC needs to be thinned with SRC Thinners (DCT) before spraying. The optimum viscosity to give
coating quality and thickness depends on the spray equipment and conditions but a starting point could be 2
parts coating to 1 part thinners. If bulk coating material has been agitated, allow to stand until air bubbles
have dispersed. The nozzle of the spray gun requires to be selected to give an even spray to suit the
viscosity of the coating material.
SRC is suitable both for use in manual spray guns and computer controlled airless spray equipment that
only coats the required areas of the PCB, eliminating the need for masking.
To ensure penetration of the coating beneath the components and in confined spaces, spray the assembly
from all directions to give an even coating.
After spraying, the boards should be placed in an air-circulating drying cabinet and left to dry for 2 hours at
room temperature prior to any heat curing.
Brushing
Ensure that the coating material has been agitated thoroughly and has been allowed to settle for at least 2
hours. The coating should be kept at ambient temperature. Gently apply the coating with a good quality
brush so as not to leave brush marks and so that the components and wiring are not disturbed.
Drying Times and Curing Conditions
SRC will dry in air within 4 to 12 hours at room temperature. This cure time can be reduced by the use of
moderate heat. The coating should be tack free within 20 minutes. Any heat cure must be started after the
coating has become tack free.
TYPICAL PROPERTIES
Colour:
Non-volatile Content:
Viscosity at 25°C :
Surface Resistivity (Ohms) :
Specific Gravity at 25°C:
Flash Point
Temperature Range:
Clear Translucent Fluid
33% approx.
45 mPa.s
11
2.2x10
1.03
20°C
-50°C to +125°C
PACKAGING
ORDER CODE
400ml aerosol
5 Litre Bulk
SRC400
SRC05L
Thinners
5 Litre Bulk
DCT05L
Copyright Electrolube 1997
All information is given in good faith but without warranty. Properties are given as a guide only and should not be taken as a specification.
Electrolube cannot be held responsible for the performance of its products within any application determined by the customer, who must
satisfy themselves as to the suitability of the product.