ETC P74F-6GC-PFN

P74F
Excelon® 74
Soft Start/Dump Valve
3/8", 1/2", 3/4" Port Size
● EXCELON design allows inline or modular installation
● Controlled increase of downstream pressure on
start up
● Solenoid or air pilot operation
● High forward flow capacity
● High flow dump facility
● Optional manual dump facility with lockout
Soft start valves allow a controlled increase of pressure
onto downstream cylinder/machines offering protection
to personnel and equipment.
The dump feature can be activated by removing power
to the solenoid or the air pilot, or by operating the
manual dump.
Note: Turn on system air supply prior to applying pilot
signal to operator. Failure to do so may cause valve to
continuously exhaust.
Technical Data
Fluid: Compressed air
Maximum pressure solenoid operated:
Dependant on solenoid rating
[must not exceed 17 bar (250 psig)]
Maximum pressure pilot operated: 17 bar (250 psig) max.
Minimum operating pressure: 3 bar (44 psig)
Operating temperature solenoid operated:
Dependant on solenoid rating
[must be within range -20°C* to +80°C (0°F* to +175°F)]
Operating temperature pilot operated:
-20°C* to +80°C (0°F* to +175°F)
Materials:
Body: Aluminium
Intermediate body: Aluminium
Elastomers: Synthetic materials
Filter discs: Sintered plastic
Internal components: Brass/steel
Top plate: Zinc
Exhaust bonnet: Zinc
* Consult our technical service for use below +2°C
Air pilot port:
ISO Rc1/4 with ISO Rc main ports
ISO Rc1/4 with ISO G main ports
1/4” PTF with PTF main ports
Exhaust port:
ISO G1/2 with ISO G main ports
ISO G1/2 with ISO Rc main ports
1/2” PTF with PTF main ports
Typical flow with 6,3 bar (90 psig) inlet pressure and pressure
drop of 0.5 bar (7 psig):
57 dm3/s (P1 to P2 = Cv 4.4) (P2 to P3 = Cv 5.6)
Snap pressure:
Full flow when downstream pressure reaches 50 – 80% of
inlet pressure
Charge time:
For 2 litre downstream volume and 6,3 bar (90 psig)
inlet pressure:
0,2 sec. minimum
76 sec. maximum
7/97
Ordering Information
See Ordering Information on the following
pages.
ISO Symbols
Solenoid operated
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
Air pilot
N/AL.8.200.610.01
P74F
Typical Performance Characteristics
PORT SIZE: 1/2"
bar g
MAXIMUM CHARGE TIME
psig
bar g
psig
FLOW CHARACTERISTICS
0,8
2 LITRE DOWNSTREAM VOLUME
16
INLET PRESSURE: bar g (psig)
200
OUTLET PRESSURE
PRESSURE DROP
10
6,3
8
(91) (116) (150)
3 4,0
(44) (58)
10
0,6
8
6
0,4
4
12
160
120
SNAP POINT
80
0,2
4
2
0
8
40
0
0
0
0
20
40
40
80
60
120
80
160
100
200
0
dm3/s
0
20
40
60
80
100
120
CHARGE TIME - (S)
240 scfm
AIR FLOW
Ordering Information. Models listed are with ISO G ports. Solenoid models are with 24 V d.c. coils and plug without indicator.
Port Size
G3⁄8
G1⁄2
G3⁄4
Solenoid Operated*
Model
P74F-3GC-PFA
P74F-4GC-PFA
P74F-6GC-PFA
Weight kg
1,08
1,05
1,41
Air Pilot Operated
Model
P74F-3GA-NNN
P74F-4GA-NNN
P74F-6GA-NNN
Weight kg
1,05
1,02
1,35
* To select other solenoid type and coil voltage refer to alternative models table below.
Alternative Models
P 7 4 F - ★ ★ ★ - ★★ ★
Port Size
3/8"
1/2"
3/4"
Substitute
3
4
6
Connectors
3 pin plug with cable gland,
no indicator
Without
Substitute
A
Threads
PTF
ISO Rc taper
ISO G parallel
Substitute
A
B
G
Coil Voltage
Substitute
Operator
Substitute
Air pilot**
A
Air pilot with manual lockout slide**
B
22 mm miniature solenoid
C
22 mm miniature solenoid with
manual lockout slide
D
CNOMO solenoid
L
CNOMO solenoid with
manual lockout slide
M
24 V d.c.
12 V d.c.
6 V d.c.
220/240 V
50/60 Hz
110/120 V
50/60 Hz
No coil
No solenoid
Nominal
Power Rating
2W
2W
2W
4/2,5 VA
N
F
E
D
B
4/2,5 VA
A
2W
Z
N
Solenoid Manual Operator
Shrouded push button
None
Substitute
P
N
** to order air pilot models also substitute ‘NNN’
at digits 8, 9 and 10 e.g. P74F-4GA-NNN.
N/AL.8.200.610.02
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
7/97
P74F
Accessories
Quikclamp and
Quikclamp Wall Bracket
Ø 50 mm
Pressure Gauge
4314-52
4 bar (60 psig):
10 bar (150 psig):
25 bar (360 psig):
R1/8 Connection
1/8 PTF Connection
Manual Shut-off with Lockout
18-013-012
18-013-013
18-013-014
18-013-202
18-013-204
18-013-206
Factory fit option only.
See alternative models table.
Plug with Cable Gland
for 22 mm Solenoid
Exhaust Port Silencer
MB004B (R1/2)
MB004A (1/2 PTF)
M/P24121/1*
M/P24121/2
M/P24121/3
M/P19063
12–24 V ac/dc
150–230 V ac
150–230 V ac
Indicator type
Indicator type
Indicator type
No Indicator
* Reduced light intensity at 12 V.
Dimensions mm (inches)
37 (1.46)
96 (3.78) min.
84 (3.31)
96 (3.78) min.
37 (1.46)
74 (2.91)
37 (1.46)
74 (2.91)
Air pilot operated plus
manual shut-off with lockout
84 (3.31)
84 (3.31)
165 (6.50)
212 (8.35)
Rc1/4 (1/4 PTF)
162 (6.38)
30 (1.18) A/F
107 (4.21)
G1/2 (1/2 PTF)
30 (1.18) A/F
221 (8.70)
G1/2 (1/2 PTF)
30 (1.18) A/F
144 (5.67)
G1/2 (1/2 PTF)
30 (1.18) A/F
88 (3.46)
G1/2 (1/2 PTF)
156 (6.14)
37 (1.46)
84 (3.31)
Solenoid operated plus
manual shut-off with lockout
111 (4.37) max.
Air pilot operated
111 (4.37) max.
Solenoid operated
Rc1/4 (1/4 PTF)
Service Kits
Item
Service kit
Type
All models
Part number
4384-220
Service kit includes seals for ports, body, flow adjuster, exhaust bonnet, lockout
assembly, CNOMO solenoid, flow adjuster, top plate, feed spool, soft start spool
and exhaust piston. Also included; main valve, feed valve pin, tamper resistant plug
and lockout spring.
7/97
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
N/AL.8.200.610.03
P74F
Bracket Mounting
Quikclamp and Quikclamp Wall Bracket
Use 6 mm (7/32") screws to mount bracket to wall
Port CL
51 (2.01)
82,5 (3.25)
101 (3.98)
24 (0.95)
Bracket Kit Reference
Item
Quikclamp and Quikclamp Wall Bracket
Part Number
4314-52
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
N/AL.8.200.610.04
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
7/97