ETC LHR1001-2

HR/GR SERIES
Rated for use in convection applications, the HR/GR Series delivers
high reliability power with a Mean Time Between Failure (MTBF) in
excess of 5 million hours. The HR/GR series is in compliance with the
latest national and international regulatory compliance and displays
the CE Mark.
Power-One’s HR/GR Series of encapsulated AC/DC power supplies
provides compact power to a wide range commercial and industrial
applications. With a universal input from 85 to 265 VAC, compact
case and high reliability, the HR/GR-family is an excellent choice for
a PCB mountable AC-DC converter in space-critical applications.
Selected models provide output voltage trimming through an external
trim pin.
FEATURES
• Universal Input, 85-265VAC
• Single and Dual Outputs
• -10 to +50°C Ambient Operation
• 4.2kV Isolation
• Overcurrent Protected
• Input Transient & ESD Compliance to EN61000-4-2/-4/-5
• Greater than 5,000,000 Hours MTBF
• CE marked to Low Voltage Directive
• Class II Equipment (Double Insulation)
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
LHR 1101-2
LHR 1001-2
LHR 1301-2
LHR 1501-2
LHR 1601-2
LGR 1101-2
LGR 1001-2
LGR 1301-2
LGR 1501-2
LGR 1601-2
OUTPUT
WATTAGE
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
mV (NOTE 1)
INITIAL SETTING
ACCURACY
10
10
10
10
10
23
25
25
25
25
3.3V
5V
12V
15V
24V
3.3V
5V
12V
15V
24V
3.0V to 3.6V
4.5V to 5.5V
10.8V to 13.2V
13.5V to 16.5V
21.6 to 26.4V
3.0V to 3.6V
4.5V to 5.5V
10.8V to 13.2V
13.5V to 16.5V
21.6 to 26.4V
3.0A
2.0A
0.84A
0.67A
0.42A
7.0A
5.0A
2.1A
1.7A
1.0A
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
90
150
150
150
150
90
150
240
300
300
3.24V to 3.36V
4.90V to 5.10V
11.76V to 12.24V
14.70V to 15.30V
23.52V to 24.48V
3.24V to 3.36V
4.90V to 5.10V
11.76V to 12.24V
14.70V to 15.30V
23.52V to 24.48V
MULTIPLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT
WATTAGE
LHR 2320-2
10
LHR 2540-2
10
LGR 2020-2
25
LGR 2320-2
25
LGR 2540-2
25
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
mV (NOTE 1)
INITIAL SETTING
ACCURACY
+12V
-12V
+15V
-15V
+5V
+12V
+12V
-12V
+15V
-15V
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
0.42A
0.42A
.335A
.335A
2.5A
1.0A
1.0A
1.0A
0.8A
0.8A
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
±2.0%
240
240
300
300
150
240
240
240
300
300
11.76V to 12.24V
-11.76V to -12.24V
14.70V to 15.30V
-14.70V to -15.30V
4.90V to 5.10V
11.76V to 12.24V
11.76V to 12.24V
-11.76V to -12.24V
14.70V to 15.30V
-14.70V to -15.30V
NOTE: 1) Maximum peak-to-peak noise, 20 MHz bandwidth.
Rev. 09/2000
1
HR/GR SERIES
INPUT SPECIFICATIONS (NOTE 1)
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Input Voltage - AC
Input Voltage - DC
Input Frequency
Hold-up Time
Input Current
Continuous input range.
Continuous input range.
AC Input.
Over full AC input voltage range at full rated load.
100 VAC at full rated load.
85
110
47
3
Fusing
Recommended 250V, slow blow fuse.
Inrush Surge Current
Internally limited by thermistor, one cycle, 25OC, 255VAC.
Operating Frequency
Switching frequency of main transformer.
LHR Series
LGR Series
LHR Series
LGR Series
LHR Series
LGR Series
NOM
MAX
UNITS
265
330
400
VAC
VDC
Hz
mS
0.3
0.6
T1.25A
T2.0A
80
ARMS
25
30
120
kHz
MAX
UNITS
APK
NOTE: 1) Maximum peak to peak expressed as a percentage of output voltage, 20 MHz bandwidth.
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Efficiency
Full rated load, 110VAC.
Minimum loads
Minimum load required for regulation.
Ripple and Noise
Output Power
Overshoot / Undershoot
Transient Response
Full load, 20 MHz bandwidth.
MIN
LHR Series
LGR Series
Single output models
Dual output models
Output voltage overshoot/undershoot at turn-on.
Recovery time, to within 1% of initial set point due to a 100 to 50% load change,
3% max. deviation.
NOM
73
77
76
80
0
20
See Model Selection Charts
See Model Selection Charts
0
500
%
%
V
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
MIN
Overload Protection
Foldback protected against output overload and short circuit. Automatic recovery
upon removal of overload condition.
Percentage of output, single output models only.
90
Output Adjust Range
NOM
MAX
UNITS
110
%
MAX
UNITS
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (LGA).
Input to output.
Dielectric Withstand Voltage
Input to Output Capacitance
MIN
NOM
Approved
4200
LHR Series
LGR Series
Electromagnetic Interference
ESD Susceptibility
EFT/Burst
Input Transient Protection
EN55011 / CISPR 11 and EN55022 / CISPR 22 conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-4, level 3.
Per EN61000-4-5 class 3.
Insulation Resistance
Leakage Current
Input to output..
Per EN60950, 230VAC, 50Hz.
Line to Ground
Line to Line
LHR Series
LGR Series
2
VDC
2400
5000
pF
B
15
±2.0
2.0
1.0
300
Class
kV
kV
kV
M
0.14
0.24
mA
HR/GR SERIES
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating.
Non-Operating.
Operating ambient temperature.
Operating case temperature.
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
MTBF
MIN
NOM
-10
-10
-25
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Per EN60068-2-27, MIL-STD-810D section 516.3.
Per EN60068-2-6, MIL-STD-810D section 514.3.
Calculated, MIL-HDBK-217F, 30°C, ground benign, LHR models.
Calculated, MIL-HDBK-217F, 30°C, ground benign, LGR models.
MAX
UNITS
10k
40k
50
80
100
ASL Ft.
ASL Ft.
±0.05
5
95
20
2
7,180,000
5,660,000
5.6/160
Unit Weight
°C
°C
%/°C
%RH
G
GRMS
Hours
oz/gm
OUTPUT VOLTAGE ADJUSTMENT
The output voltage may be adjusted within ±10% of V1 by means of an external potentiometer or fixed resistor (see table).
R1 (K )
MODEL
Output voltage adjustment for single output models
LHR 1001-2
LHR 1301-2
LHR 1501-2
LHR 1601-2
LGR 1001-2
LGR 1301-2
LGR 1501-2
LGR 1601-2
R2(K )
V1 + 5%
V1+ 10%
V1 – 5%
V1 –10%
5.2
8.2
26.0
10.0
5.2
8.2
18.0
10.0
1.0
0.39
9.9
820
1.0
0.49
1.7
820
4.6
49.0
148
140
4.6
48.3
141
140
0.10
18.9
66.3
61.0
0.10
18.9
58.0
61.0
LGR BOTTOM VIEW
LHR BOTTOM VIEW
HR/GR SERIES PIN OUT
PIN
LHR SINGLE
OUTPUT
LHR DUAL
OUTPUT
LGR SINGLE
OUTPUT
LGR DUAL
OUTPUT
1
2
3
4
5
6
LINE
NEUTRAL
+V1
VOLTAGE ADJUST
-V1
N/C
LINE
NEUTRAL
+V1
N/C
-V2
COMMON
LINE
NEUTRAL
+V1
-V1
VOLTAGE ADJUST
NO PIN
LINE
NEUTRAL
+V1
COMMON
V2
NO PIN
3
HR/GR SERIES
OPTIONS
Option Descriptions
OPTION
DESCRIPTION
OPTION
DESCRIPTION
OPTION
DESCRIPTION
A
Test sockets
i
Inhibit input
V
ACFAIL signal (for 5.1 V output)
B
Cooling plate large
K
Alternative pinout
Y
Small soldering pins
B1
Cooling plate small
L
Input filter (Non-Isolated Models Only)
Z
Cell voltage selector switch
C
Thyristor-Crowbar
L
Surface mount package
-0
Ambient temperature range –40 to 60°C
D
"Save Data" signal
M
Surface mount package
-6
Hermetic semi-conductors
E
Inrush current limitation
P
Potentiometer
-7
ambient temperature range –25 to 71°C
F
Input fuse internally (not accessible)
R
External output voltage control
-8
Ambient temperature range –40 to 85°C
H
Increased electric strength test voltage
T
Current sharing
-9
Ambient temperature range –40 to 71°C
NOTE: Not all options are available for every product series
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
4