Advanced Produc t Release NET1 SERIES Designed to meet the stringent requirements of today’s high-speed datacom and telecom circuitry, Power-One’s NET1 series is an excellent compact power solution for low-voltage, high-current applications. The NET1’s high efficiency is achieved through the use of synchronous rectification and a newly-patented “Soft Transition Forward Converter”. The NET1’s rectification method lowers output losses, reduces system cooling requirements (allowing greater power in a smaller package), and eliminates minimum load requirements. Advanced surface-mount design and packing technology reduce the NET1’s height to 1.35” (34.3mm) to fit in 1U applications. NET1’s high-performance active power factor circuitry meets EN61000-3-2 requirements for compliance with European Power Line Harmonic Requirements for 2001. A multifunctional output terminal allows connection to #8 ring lugs, 0.25” quick disconnects, cable connectors, and PCB-mounted connectors. FEATURES • Currents Over 100 Amps • Fits 1U Chassis Height Constraints • No Minimum Load Requirement • Current Share Capabilities on All Outputs • Patented High-Efficiency Design • Meets European Power Factor Requirements for 2001 • Excellent Load Transient Response MULTIPLE OUTPUT MODEL SELECTION CHART – 240W WITH 300 LFM FORCED AIR COOLING MODEL NET1-4325 NET1-4130 NET1-4112 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %Pk-Pk (NOTE 2) INITIAL SETTING ACCURACY +3.3V +2.5V +5V +12V +1.8V +3.3V +5V +12V +1.8V +1.65V +5V +12V +0.5V +0.5V FIXED FIXED +0.5V +0.5V FIXED FIXED +0.5V +0.5V FIXED FIXED 50A 50A 5A 4A 50A 50A 5A 4A 50A 50A 5A 4A 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 1% 1% 3% 3% 1% 1% 3% 3% 1% 1% 3% 3% 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV 1% or 50mV ± 30mV ± 30mV ± 30mV ± 100mV ± 20mV ± 30mV ± 30mV ± 100mV ± 20mV ± 30mV ± 30mV ± 100mV MAX UNITS 264 63 VAC Hz mS ARMS 35 APK W/VA NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage - AC Input Frequency Hold-up Time Input Current Input Protection Inrush Surge Current Power Factor Continuous input range. AC input. After last AC line peak at 240 watts. 85 VAC at full rated load. Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 220 VAC, one cycle, 25°C. Per EN61000-3-2. 85 47 20 Rev. 11/2000 1 TYP 4.0 0.95 Advanced Produc t Release NET1 SERIES OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Efficiency Ripple and Noise Output Power Overshoot / Undershoot Regulation Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. Full load, 20 MHz bandwidth. With 300 LFM forced air cooling. (Note 1) Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes over the specified. input range, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 10-100% load change, 1% max. deviation. Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%. Transient Response Turn-on Delay Turn-on Rise Time MIN TYP MAX 80 See Model Selection Charts 240 0 UNITS % Watts % See Model Selection Charts 500 µS 2 20 Sec mS INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection Overvoltage protection on all outputs. Maximum + 0.5V Unit latches off when overvoltage is detected. AC input must be recycled to reset. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. Open collector global Output Good signal. The signal activates when any of the outputs drop below 5%. Open collector signal. Time before regulation dropout due to loss of input 5 power. May be used as independent PSOK signal in redundant applications. Available on all outputs. Accuracy of shared current with up to 6 parallel units. 10 Single wire current share. Available on all outputs. Total voltage compensation for cable losses with 500 respect to the main output. Overload Protection Overtemperature Protection Output Good Input Power Fail Warning Current Share Remote Sense MIN TYP MAX UNITS mS % mV SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Agency Approvals ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection UL1950. CSA 22.2 NO. 234/950. EN60950 (TÜV). Input to output per EN60950. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 3. Per EN61000-4-5, class 3. Insulation Resistance Input to output. Dielectric Withstand Voltage Electromagnetic Interference MIN TYP MAX Approved Line to Line Line to Ground 2600 B B 8 10 ±2 1 2 VDC Class kV V/M kV kV 10 NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 2 UNITS M Advanced Produc t Release NET1 SERIES ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-Operating. Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration MIN At 100% load 0°C to 70°C (after 15-minute warmup). Non-Condensing. Peak acceleration. Random vibration, 10 Hz to 2 kHz, 3 axis. TYP 0 -40 ±0.02 5 MAX UNITS 10k 40k 50 85 ±0.05 95 20 6 ASL Ft. ASL Ft. °C °C %/°C %RH GPK GRMS MECHANICAL DESCRIPTION NOTES Metric Mounting Size M4 x 0.7 mounting inserts: 2 mounting surfaces SIZE IMPACT 7.00" x 4.50" x 1.35" (177.8mm x 114.3mm x 34.3mm) 3