MAP30/40/42 AC-DC Series Data Sheet Features • RoHS lead-solder-exempt compliant • Universal input 85-264 VAC • CE marked to Low Voltage Directive • Input transient & ESD compliance to EN61000-4-2/-3/-4 • Meets EN55022 conducted and radiated limits • Greater than 311,000 Hours MTBF • Remote sense (MAP30, MAP42) Description Power-One’s MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Fixed frequency operation simplifies system level operation. The MAP30/40/42 Series is configured to the international standard 3.00" x 5.00" footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. Single-Output Model Selection MODEL MAP30-1005 MAP42-1005 MAP42-1012 MAP42-1024 NOTES: OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT PEAK OUTPUT CURRENT (NOTE 2) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 1) INITIAL SETTING ACCURACY 5V 5V 12V/15V 24V/28V 4.7V to 5.8V 4.7V to 5.8V 11.0V to 18.0V 23.0V to 29.0V 6A 8A 3.4/2.7A (Note 3) 1.7/1.4A (Note 3) 8A 11A 4.6/3.7A (Note 3) 2.3/1.9A (Note 3) 0.2% 0.2% 0.2% 0.2% ±1% ±1% 1% 1% 1% 1% 1% 1% 4.9V to 5.1V 4.9V to 5.1V 11.9V to 12.1V 23.8V to 24.2V 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling. 3) MAP42-1012 output currents are expressed as 12V/15V operation. MAP42-1024 output currents are expressed as 24V/28V operation. Multiple-Output Model Selection – 40W CONTINUOUS OUTPUT POWER MODEL MAP40-3000 MAP40-3100 MAP40-3101 MAP40-3105 MAP40-3500 MAP40-3003 NOTES : 1) 2) 3) 4) OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT PEAK OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY +5V +12V -12V +5V +12V -12V +5V +24V -12V +5V +12 -5V +5V +12V -12V +5V +15V -15V 4.75V to 5.50V Fixed Fixed 4.75V to 5.25V Fixed Fixed 4.75V to 5.25V Fixed Fixed 4.7V to 5.8V Fixed Fixed 4.7V to 5.8V Fixed Fixed 4.7V to 5.8V Fixed Fixed 3A 2A 0.3A 3A 2A 0.3A 3A 1A 0.3A 3A 2A 0.5A 5A 1A 0.3A 3A 1.5A 0.2A 5A 3.5A 0.5A 5A 3.5A 0.5A 5A 1.5A 0.5A 5A 3.5A 1.0A 6A 3.5A 0.5A 5A 3A 0.5A 0.2% 1% 1% 0.2% 1% 1% 0.2% 1% 1% 0.2% 1% 1% 0.2% 1% 1% 0.2% 1% 1% 2% 3.5% (Note 3) 2% (Note 4) 2% 3.5% (Note 3) 2% 2% 3.5% (Note 3) 2% 2% 3.5% (Note 3) 2% 2% 3.5% (Note 3) 2% 2% 3.5% (Note 3) 2% (Note 4) 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 4.9V to 5.1V 11.5V to 12.5V -11.4V to -12.6V 4.9V to 5.1V 11.5V to 12.5V -11.4V to -12.6V 4.9V to 5.1V 23.0V to 25.0V -11.5V to -12.5V 4.9V to 5.1V 11.5V to 12.5V -4.75V to -5.25V 4.9V to 5.1V 11.5V to 12.5V -11.4V to -12.6V 4.9V to 5.1V 14.7V to 15.3V -14.3V to -15.7V Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.). Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. Quasi regulated output. See Regulation Curves for more information. Requires a minimum load of 0.5A on V1 or 0.3A on V2. REV. SEP 07, 2004 revised to JUN 19, 2006 Page 1 of 5 www.power-one.com MAP30/40/42 AC-DC Series Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION Input Voltage - AC Continuous input range. MIN Input Frequency Brown Out Protection Hold-up Time Input Current Input Protection Inrush Surge Current AC input. Lowest AC input voltage that regulation is maintained with full rated loads. Nominal AC Input Voltage (115VAC), full rated load. 90 VAC (40W load). Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C. 38 APK Operating Frequency Switching frequency of power supply (fixed frequency). 23 25 30 kHz PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Minimum Loads Turn-on Delay Full load, 120VAC. Single output models; MAP30, MAP42. All multiple output models, see regulation graphs. Full load, 20 MHz bandwidth. Multiple output models with convection cooling. Output voltage overshoot/undershoot at turn-on, V1. Varies by output, total regulation includes: Line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only of multiple output units). Time required for initial output voltage stabilization. Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. MAP42 MAP30, MAP40 NOM 85 90 47 85 15 MAX UNITS 264 264 63 VAC 1.2 Hz VAC ms ARMS Output Specifications Ripple and Noise Output Power Overshoot / Undershoot Regulation Transient Response 70 % Amps 0.0 See Model Selection Chart. 40 Watts 1 % See regulation graphs. μs 500 1 2 20 Sec ms Interface Signals and Internal Protection PARAMETER Overvoltage Protection Overload Protection Remote Sense CONDITIONS/DESCRIPTION MIN MAP30-1005, MAP42-1005 MAP42-1012 MAP42-1024 Main output only of multiple output units. Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Total cable drop, single output models only. 5.8 20.0 32.0 5.8 NOM MAX UNITS 6.8 22.0 37.0 6.8 V 130 % 250 mV MAX UNITS Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL60950. CSA 22.2 No. 60950. EN60950 (TUV). Input to output. Dielectric Withstand Voltage Electromagnetic Interference Input Transient Protection Insulation Resistance Leakage Current NOTES: MIN Approved. 2600 FCC CFR title 47 part 15 sub-part B - conducted. EN55022 / CISPR 22 conducted (Note 1). EN55022 / CISPR 22 radiated (Note 2). EN61000-4-5 Level 3 Input to output. Per EN60950, 264VAC NOM VDC B B B Line to Line Line to Ground MAP42, MAP40-3100, 3001, 3105, 3500 MAP30-1005, MAP40-3000, MAP40-3003 Class 1 2 7 kV MΩ 500 750 μA 1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A. 2) MAP40-3000, MAP40-3003, MAP3500 meet Class A. REV. SEP 07, 2004 revised to JUN 19, 2006 Page 2 of 5 www.power-one.com MAP30/40/42 AC-DC Series Data Sheet Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-operating. Derate linearly above 50°C by 2.5% per °C to a maximum temperature of 70°C. Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration MIN 0°C to 70°C (after 15 minute warm-up). Non-condensing. Operating, peak acceleration. Random vibration, 10Hz to 2kHz, 3 axis. At 100% load: At 50% load: NOM 0 0 -40 ±0.02 5 MAX UNITS 10k 40k 50 70 85 ±0.03 95 20 6 ASL Ft. ASL Ft. °C °C °C %/°C %RH G GRMS NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. SEP 07, 2004 revised to JUN 19, 2006 Page 3 of 5 www.power-one.com MAP30/40/42 AC-DC Series Data Sheet MAP40-3500 TYPICAL QUASI REGULATION PERFORMANCE FOR +12V OUTPUT 14.25 12V OUTPUT VOLTAGE 13.75 13.25 12.75 +5V @ 5.0 Amps 12.25 +5V @ 3.0 Amps +5V @ 1.0 Amps 11.75 +5V @ 0 Amps 11.25 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 12V OUTPUT CURRENT MAP40-3000/3100/3105 TYPICAL QUASI REGULATION PERFORMANCE FOR +12V OUTPUT 12V OUTPUT VOLTAGE 13.5 13.0 12.5 12.0 +5V @ 3.0 Amps +5V @ 1.8 Amps 11.5 +5V @ 0.6 Amps +5V @ 0 Amps 11.0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 12V OUTPUT CURRENT MAP40-3003 TYPICAL QUASI REGULATION PERFORMANCE FOR +15V OUTPUT 17.0 16.5 15V OUTPUT VOLTAGE 16.0 15.5 15.0 +5V @ 3.0 Amps +5V @ 1.8 Amps 14.5 +5V @ 0.6 Amps +5V @ 0 Amps 14.0 13.5 0 0.15 0.3 0.45 0.6 0.75 0.9 1.05 1.2 1.35 1.5 15V OUTPUT CURRENT REV. SEP 07, 2004 revised to JUN 19, 2006 Page 4 of 5 www.power-one.com MAP30/40/42 AC-DC Series Data Sheet OVERALL SIZE: 5.00" x 3.00" x (see table) (127.0mm x 76.2mm x see table) WEIGHT: 0.6 lb (0.26 kg) J1 MAP30 J2 NEUTRAL PIN 1 LINE PIN 2 PIN 7 N/C V1 V1 GND GND +Sense -Sense J3 SAFETY EARTH GROUND (0.250" x 0.032" FASTON) PIN 1 MAP40 J2 PIN 6 PIN 1 V2 V1 V1 GND GND V3 MAP42 J2 PIN 6 PIN 1 V1 V1 GND GND +Sense -Sense J1/J2 MATES WITH MOLEX (SERIES 2139 or SERIES 41695) .156" (4mm) CENTER CRIMP TERMINAL HOUSING OR EQUIVALENT MAP30/40/42 SERIES HEIGHT Single Output Models Multiple Output Models Model Height Model Height MAP30-1005 MAP42-1005 MAP42-1012 MAP42-1024 1.16" (29.5) 1.25" (31.8) 1.25" (31.8) 1.25" (31.8) MAP40-3000 MAP40-3003 MAP40-3100 MAP40-3101 MAP40-3105 MAP40-3500 1.16" (29.5) 1.16" (29.5) 1.25" (31.8) 1.25" (31.8) 1.25" (31.8) 1.60" (40.6) REV. SEP 07, 2004 revised to JUN 19, 2006 Page 5 of 5 www.power-one.com