POWER-ONE MAP40-3105

MAP30/40/42 AC-DC Series Data Sheet
Features
• RoHS lead-solder-exempt compliant
• Universal input 85-264 VAC
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
EN61000-4-2/-3/-4
• Meets EN55022 conducted and radiated limits
• Greater than 311,000 Hours MTBF
• Remote sense (MAP30, MAP42)
Description
Power-One’s MAP30/40/42 Series of power supplies combines low cost and universal input in a board-only power
solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure
worldwide acceptance. All units bear the CE Mark.
Fixed frequency operation simplifies system level operation. The MAP30/40/42 Series is configured to the international
standard 3.00" x 5.00" footprint. Input and output connections are made via popular single-row Molex connectors.
Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output
voltage requirements.
Single-Output Model Selection
MODEL
MAP30-1005
MAP42-1005
MAP42-1012
MAP42-1024
NOTES:
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 2)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
5V
5V
12V/15V
24V/28V
4.7V to 5.8V
4.7V to 5.8V
11.0V to 18.0V
23.0V to 29.0V
6A
8A
3.4/2.7A (Note 3)
1.7/1.4A (Note 3)
8A
11A
4.6/3.7A (Note 3)
2.3/1.9A (Note 3)
0.2%
0.2%
0.2%
0.2%
±1%
±1%
1%
1%
1%
1%
1%
1%
4.9V to 5.1V
4.9V to 5.1V
11.9V to 12.1V
23.8V to 24.2V
1) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) Peak ratings may be used as maximum output current with 100 Linear Feet per Minute (LFM) forced air cooling.
3) MAP42-1012 output currents are expressed as 12V/15V operation. MAP42-1024 output currents are expressed as 24V/28V operation.
Multiple-Output Model Selection – 40W CONTINUOUS OUTPUT POWER
MODEL
MAP40-3000
MAP40-3100
MAP40-3101
MAP40-3105
MAP40-3500
MAP40-3003
NOTES :
1)
2)
3)
4)
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 1)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
+5V
+12V
-12V
+5V
+12V
-12V
+5V
+24V
-12V
+5V
+12
-5V
+5V
+12V
-12V
+5V
+15V
-15V
4.75V to 5.50V
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
4.7V to 5.8V
Fixed
Fixed
3A
2A
0.3A
3A
2A
0.3A
3A
1A
0.3A
3A
2A
0.5A
5A
1A
0.3A
3A
1.5A
0.2A
5A
3.5A
0.5A
5A
3.5A
0.5A
5A
1.5A
0.5A
5A
3.5A
1.0A
6A
3.5A
0.5A
5A
3A
0.5A
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
0.2%
1%
1%
2%
3.5% (Note 3)
2% (Note 4)
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2%
2%
3.5% (Note 3)
2% (Note 4)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
23.0V to 25.0V
-11.5V to -12.5V
4.9V to 5.1V
11.5V to 12.5V
-4.75V to -5.25V
4.9V to 5.1V
11.5V to 12.5V
-11.4V to -12.6V
4.9V to 5.1V
14.7V to 15.3V
-14.3V to -15.7V
Peak loads for 30 seconds or less are acceptable, (10% duty cycle max.).
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
Quasi regulated output. See Regulation Curves for more information.
Requires a minimum load of 0.5A on V1 or 0.3A on V2.
REV. SEP 07, 2004 revised to JUN 19, 2006
Page 1 of 5
www.power-one.com
MAP30/40/42 AC-DC Series Data Sheet
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Input Voltage - AC
Continuous input range.
MIN
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC Input Voltage (115VAC), full rated load.
90 VAC (40W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
38
APK
Operating Frequency
Switching frequency of power supply (fixed frequency).
23
25
30
kHz
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Minimum Loads
Turn-on Delay
Full load, 120VAC.
Single output models; MAP30, MAP42.
All multiple output models, see regulation graphs.
Full load, 20 MHz bandwidth.
Multiple output models with convection cooling.
Output voltage overshoot/undershoot at turn-on, V1.
Varies by output, total regulation includes: Line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing
to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only of multiple output units).
Time required for initial output voltage stabilization.
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
MAP42
MAP30, MAP40
NOM
85
90
47
85
15
MAX
UNITS
264
264
63
VAC
1.2
Hz
VAC
ms
ARMS
Output Specifications
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
70
%
Amps
0.0
See Model Selection Chart.
40
Watts
1
%
See regulation graphs.
μs
500
1
2
20
Sec
ms
Interface Signals and Internal Protection
PARAMETER
Overvoltage
Protection
Overload
Protection
Remote Sense
CONDITIONS/DESCRIPTION
MIN
MAP30-1005, MAP42-1005
MAP42-1012
MAP42-1024
Main output only of multiple output units.
Fully protected against output overload and short circuit. Automatic
recovery upon removal of overload condition.
Total cable drop, single output models only.
5.8
20.0
32.0
5.8
NOM
MAX
UNITS
6.8
22.0
37.0
6.8
V
130
%
250
mV
MAX
UNITS
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Agency Approvals
UL60950.
CSA 22.2 No. 60950.
EN60950 (TUV).
Input to output.
Dielectric Withstand
Voltage
Electromagnetic
Interference
Input Transient
Protection
Insulation Resistance
Leakage Current
NOTES:
MIN
Approved.
2600
FCC CFR title 47 part 15 sub-part B - conducted.
EN55022 / CISPR 22 conducted (Note 1).
EN55022 / CISPR 22 radiated (Note 2).
EN61000-4-5 Level 3
Input to output.
Per EN60950, 264VAC
NOM
VDC
B
B
B
Line to Line
Line to Ground
MAP42, MAP40-3100, 3001, 3105, 3500
MAP30-1005, MAP40-3000, MAP40-3003
Class
1
2
7
kV
MΩ
500
750
μA
1) MAP30-1005, MAP40-3000, MAP40-3003 meet Class A.
2) MAP40-3000, MAP40-3003, MAP3500 meet Class A.
REV. SEP 07, 2004 revised to JUN 19, 2006
Page 2 of 5
www.power-one.com
MAP30/40/42 AC-DC Series Data Sheet
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
Altitude
Operating.
Non-operating.
Derate linearly above 50°C by 2.5%
per °C to a maximum temperature of 70°C.
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
MIN
0°C to 70°C (after 15 minute warm-up).
Non-condensing.
Operating, peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
At 100% load:
At 50% load:
NOM
0
0
-40
±0.02
5
MAX
UNITS
10k
40k
50
70
85
±0.03
95
20
6
ASL Ft.
ASL Ft.
°C
°C
°C
%/°C
%RH
G
GRMS
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
REV. SEP 07, 2004 revised to JUN 19, 2006
Page 3 of 5
www.power-one.com
MAP30/40/42 AC-DC Series Data Sheet
MAP40-3500 TYPICAL QUASI REGULATION
PERFORMANCE FOR +12V OUTPUT
14.25
12V OUTPUT VOLTAGE
13.75
13.25
12.75
+5V @ 5.0 Amps
12.25
+5V @ 3.0 Amps
+5V @ 1.0 Amps
11.75
+5V @ 0 Amps
11.25
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
12V OUTPUT CURRENT
MAP40-3000/3100/3105 TYPICAL QUASI REGULATION
PERFORMANCE FOR +12V OUTPUT
12V OUTPUT VOLTAGE
13.5
13.0
12.5
12.0
+5V @ 3.0 Amps
+5V @ 1.8 Amps
11.5
+5V @ 0.6 Amps
+5V @ 0 Amps
11.0
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
12V OUTPUT CURRENT
MAP40-3003 TYPICAL QUASI REGULATION
PERFORMANCE FOR +15V OUTPUT
17.0
16.5
15V OUTPUT VOLTAGE
16.0
15.5
15.0
+5V @ 3.0 Amps
+5V @ 1.8 Amps
14.5
+5V @ 0.6 Amps
+5V @ 0 Amps
14.0
13.5
0
0.15
0.3
0.45
0.6
0.75
0.9
1.05
1.2
1.35
1.5
15V OUTPUT CURRENT
REV. SEP 07, 2004 revised to JUN 19, 2006
Page 4 of 5
www.power-one.com
MAP30/40/42 AC-DC Series Data Sheet
OVERALL SIZE: 5.00" x 3.00" x (see table) (127.0mm x 76.2mm x see table)
WEIGHT: 0.6 lb (0.26 kg)
J1
MAP30 J2
NEUTRAL
PIN 1
LINE
PIN 2
PIN 7
N/C
V1
V1
GND
GND
+Sense
-Sense
J3
SAFETY EARTH GROUND
(0.250" x 0.032" FASTON)
PIN 1
MAP40 J2
PIN 6
PIN 1
V2
V1
V1
GND
GND
V3
MAP42 J2
PIN 6
PIN 1
V1
V1
GND
GND
+Sense
-Sense
J1/J2 MATES WITH MOLEX (SERIES 2139 or SERIES 41695) .156" (4mm)
CENTER CRIMP TERMINAL HOUSING OR EQUIVALENT
MAP30/40/42 SERIES HEIGHT
Single Output Models
Multiple Output Models
Model
Height
Model
Height
MAP30-1005
MAP42-1005
MAP42-1012
MAP42-1024
1.16" (29.5)
1.25" (31.8)
1.25" (31.8)
1.25" (31.8)
MAP40-3000
MAP40-3003
MAP40-3100
MAP40-3101
MAP40-3105
MAP40-3500
1.16" (29.5)
1.16" (29.5)
1.25" (31.8)
1.25" (31.8)
1.25" (31.8)
1.60" (40.6)
REV. SEP 07, 2004 revised to JUN 19, 2006
Page 5 of 5