Power PCB Relay G5J Low-cost relay for electric appliances ■ PCB + Quick Connect Terminals ■ Withstands surges of 10,000 V for 1 minute ■ TV 8 available ■ Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G5J-1-TP-M-DC12). Terminal PCB + Quick Connect Contact form SPST-NO Construction Unsealed Part number G5J-1-TP-M Specifications ■ CONTACT DATA Load Rated load Contact material Carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load Resistive load (p.f. = 1) 16 A at 250 VAC, 16 A at 30 VDC AgCdO 16 A 250 VAC, 30 VDC 16 A 4,000 VA, 480 W 100 mA, 5 VDC ■ COIL DATA Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) 5 12 18 24 138.9 58.3 38.9 29.2 36 206 463 822 Coil inductance (Ref. value) (H) Armature OFF — 1.74 — 6.74 Pick-up voltage Armature ON — 1.44 — 5.22 Dropout voltage % of rated voltage 70% max. 10% min. Maximum voltage Power consumption (mW) 110% at 70°C (158°F) Approx. 700 G5J G5J ■ CHARACTERISTICS Contact resistance Operate time Release time Bounce time Operating frequency Mechanical Electrical Insulation resistance Dielectric strength Vibration Mechanical durability Malfunction durability Mechanical durability Malfunction durability Shock Ambient temperature Humidity Service life Mechanical Electrical Weight 30 mΩ max. 20 ms max. (mean value: approx. 10.20 ms) 5 ms max. (mean value: approx. 1.25 ms) Operate: (mean value: approx. 0.80 ms) 18,000 operations/hour 1,800 operations/hour (under rated load) 1,000 MΩ min. (at 500 VDC) 4,000 VAC, 50/60 Hz for 1 minute between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity 10 to 55 Hz; 1.50 mm (0.06 in) double amplitude 10 to 55 Hz; 1.50 mm (0.06 in) double amplitude 1,000 m/s2 (approx. 100 G) 150 m/s2 (approx. 15 G) -25° to 70°C (-13° to 158°F) 35% to 85% RH 2 million operations min. (at operating frequency of 18,000 operations/hour) See “Characteristic Data” Approx. 22 g (0.78 oz) Note: Data shown are of initial value. ■ CHARACTERISTIC DATA Rated operating current (A) Rated operating voltage (V) 2 Electrical service life Service life (x104 operations) Maximum switching capacity Rated operating current (A) G5J G5J Dimensions Unit: mm (inch) ■ RELAYS Terminal arrangement/ Internal connections Mounting holes (Bottom view) ■ APPROVALS UL (File No. E41643)/CSA (File No. LR31928) Type G5J-1-TP-M Contact form SPST-NO Coil ratings 6 to 24 VDC Contact ratings 16 A, 250 VAC (General use) 16 A, 30 VDC (Resistive) 1/2 HP, 125 VAC 1 HP, 250 VAC TV-8 960 WT, 120 VAC Tungsten Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GC RLY7 01/00 Specifications subject to change without notice. Printed in the U.S.A. 3