ETC SV115724

Level Sensors
Amplifier, Conductive
Types SV 110/210, SV 115/215 (Discharging)
•
•
•
•
•
•
•
SV 110/210
Level control for conductive liquids
Max.-min. control of DISCHARGING
SV 110/210: Fixed sensitivity
SV 115/225: Adjustable sensitivity
10 A SPDT or 8 A DPDT output relay
LED-indications: Power supply and relay ON
AC or DC power supply
SV 115/215
Product Description
Ordering Key
Level control relay for conductive liquids which can
control two levels of dis-
Housing
Output
Power supply
charging. Usable for one
level detection with pin 5
and 7 short-circuited.
SV 110 024
Type Selection
Plug
Output
Supply: 24 VAC
Supply: 115 VAC
Supply: 230 VAC
Supply: 24 VDC
Circular
SPDT
DPDT
SPDT
DPDT
SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
SV
110
210
115
215
024
024
024
024
110
210
115
215
115
115
115
115
110
210
115
215
230
230
230
230
Input Specifications
Supply Specifications
Level probe supply
Level probe current
Sensitivity
SV110/SV210
Power supply
AC types
Rated operational voltage
through pins 2 and 10 230
SV115/SV215
ON
OFF
ON
OFF (AC)
OFF (DC)
Max. 24 VAC
Max. 2.5 mA
From 22 to 29 kΩ
From 32 to 40 kΩ
From 2-6 to 20-30 kΩ (adj.)
From 3-13 to 30-40 kΩ (adj.)
From 3-9 to 42-52 kΩ (adj.)
General Specifications
Indication for
Power supply ON
Output ON
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Approvals
CE-marking
LED, green
LED, red (724 only red)
115
024
Rated insulation voltage
Rated impulse withstand volt.
Power supply
DC types
Rated operational voltage
724
Rated insulation voltage
Rated impulse withstand volt.
110
210
115
215
724
724
724
724
Overvoltage cat. II (IEC 60664)
230 VAC ± 15%
50/60 Hz, -5/+5 Hz
115 VAC ± 15%
50/60 Hz, -5/+5 Hz
24 VAC ± 15%
50/60 Hz, -5/+5 Hz
250 VAC (rms)
4 kV (1.2/50 µs) (line/neutral)
Overvoltage cat. II (IEC 60664)
24 VDC ± 15% (pin 2 pos.)
None
800 V (1.2/50 µs)
IP 20 B
3 (IEC 60664)
-20 to +50ºC (-4 to +122ºF)
-50 to +85ºC (-58 to +185ºF)
UL, CSA
Yes
Specifications are subject to change without notice (25.06.99)
1
SV 110/210, SV 115/215
Output Specifications
Output
Rated insulation voltage
Contact ratings (Ag-CdO)
Resistive loads
AC 1
DC 1
or
AC 15
DC 13
Small inductive loads
Mechanical life
Electrical life
Operation frequency
Insulation voltages
Rated insulation voltage
AC
DC
AC
Rated impulse withstand voltage
DC
SV110/SV115
SV210/SV215
SPDT relay
250 VAC (rms)
(cont./elec.)
µ (micro gap)
10 A/250 VAC (2500 VAC)
1 A/250 VAC (250 W)
10 A/25 VDC (250 W)
2.5 A/230 VAC
5 A/24 VDC
≥ 5 x 107 operations
≥105 operations
≤ 7200 operations/h
DPDT relay
250 VAC (rms)
(Cont./elec., cont./cont.)
µ (micro gap)
8 A/250 VAC (200 VA)
0,4 A/250 VDC (100 W)
4 A/25 VDC (100 W)
2.5 A/230 VAC
5 A/24 VDC
≥ 5 x 107 operations
≥105 operations
≤ 7200 operations/h
≥ 2.0 kVAC (rms)
(cont./elect.)
None
4 kV (1.2/50 µs)
(cont./elect.) (IEC 60664)
800 V
≥ 2.0 kVAC (rms)
(cont./elect.)
None
4 kV (1.2/50 µs)
(cont./elect.) (IEC 60664)
800 V
Mode of Operation
Max. and min. control of
discharging.
Example 1
The diagram shows the level
control connected as max.
and min. control, i.e. detec-
tion of 2 levels. The relay
operates when the max. electrode is in contact with the liquid. The relay releases when
the min. electrode is no
longer in contact with the liquid. By use of a container of
a conductive material (pin 7)
can be connected to the container. If the container is made
of a non-conductive material,
an additional electrode is
needed, indicated by the dotted line in the diagram.
Example 2
If only one level is required,
pins 5 and 7 must be interconnected to select either
max. or min. control.
Wiring Diagrams
SV 1xx/SV 2xx, two levels
Example 1
SV 1xx/SV 2xx, one level
Example 2
Max.
Min.
Power Supply
Max. or Min.
Power Supply
Operation Diagram
Accessories
Power supply
Conductive level probe:
VH..., VPC..., VPP...
VN..., VNY..., VNI...
VT..., VTI..., VS...
Max. electrode in liquid
Min. electrode in liq.
1 or 2 electrodes
Relay on
2
Specifications are subject to change without notice (25.06.99)