V03, V04 and V05 Series 2/2 and 3/2 Poppet Valves Electrically Actuated G1⁄8, G1⁄4, CNOMO and Interface ● Extensive range of power and orifice size options ● Removable coil ● Manifold rail for 1 to 20 valves ● Reduced installation height ● Exhaust diffuser supplied as standard ● Normally closed and normally open types Technical Data Ordering Information Medium: Compressed air, filtered, lubricated or non-lubricated. Operation: Poppet valve, directly actuated with spring return. Mounting: Through holes in sub-base, threaded on single station. Port Size: G1⁄8, G1⁄4 or 3mm (CNOMO and Interface) Operating Pressure: Up to 16 bar. See table overleaf. Orifice Sizes: 1,0 mm, 1,5 mm, 2,0 mm, 2,5 mm and 3,0 mm. See table overleaf. Flow: See details on page 5.4.042.03 Operating Temperature: – 30°C* to + 90°C supply air – 30°C* to + 50°C ambient To order, quote model number as indicated in the tables overleaf, e.g. V04X486L–B623A for the 3/2 model with an interface base, a 2 mm orifice and a 4,5 W, 24 V d.c. coil without plug. Coils can also be supplied, quote reference from table overleaf inserting the voltage code where marked *. * Consult our Technical Service for use below +2°C Response Times: 8 – 15 ms Materials: Glass reinforced thermoplastic encapsulated coil, stainless iron armature, stainless steel tube and spring, zinc alloy (G1⁄8 and CNOMO) or brass (G1⁄4) or polyester (interface base), nitrile rubber seals. 3 21 4/97 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 21 2 11 2 N/ ** 5.4.042.01 V03, V04, V05 Series General Information V03 Symbol 2 12 Model Type Base Orifice (mm) Maximum Operating Pressure (bar) Weight (kg) Coil Assembly without terminal box V03X286J–B613A Normally Closed Interface 1,0 10 0,20 V03X286A–Q1213 10 1 2 12 10 3 1 2 10 12 1 3 V03A286J–B613A Normally Closed G 1⁄8 1,0 10 0,24 V03X286A–Q1213 V03X486J–B613A V03X486K–B613A V03A486J–B613A V03A486K–B613A V03Y486J–B613A V03Y486K–B613A V03X386J–B613A V03X386K–B613A V03A386J–B613A V03A386K–B613A Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Open Normally Open Normally Open Normally Open Interface Interface G 1⁄8 G 1⁄8 CNOMO CNOMO Interface Interface G 1⁄8 G 1⁄8 1,0 1,5 1,0 1,5 1,0 1,5 1,0 1,5 1,0 1,5 10 4 10 4 10 4 10 4 10 4 0,20 0,20 0,24 0,24 0,30 0,30 0,20 0,20 0,24 0,24 V03X286A–Q1213 V03X286A–Q1213 V03X286A–Q1213 V03X286A–Q1213 V03X286A–Q1213 V03X286A–Q1213 V03X286A–Q1213 V03X286A–Q1213 V03X286A–Q1213 V03X286A–Q1213 Model Type Base V04X286K–B62*A V04X286L–B62*A V04X286M–B62*A V04A286K–B62*A V04A286L–B62*A V04A286M–B62*A V04B286L–B42*A V04B286M–B42*A V04B286N–B42*A V04X486J–B62*A V04X486K–B62*A V04X486L–B62*A V04X486M–B62*A V04A486J–B62*A V04A486K–B62*A V04A486L–B62*A V04A486M–B62*A V04Y486K–B62*A V04Y486L–B62*A V04Y486M–B62*A V04X386J–B62*A V04X386K–B62*A V04X386L–B62*A V04X386M–B62*A V04A386J–B62*A V04A386K–B62*A V04A386L–B62*A V04A386M–B62*A Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Open Normally Open Normally Open Normally Open Normally Open Normally Open Normally Open Normally Open Interface Interface Interface G 1⁄8 G 1⁄8 G 1⁄8 G 1⁄4 G 1⁄4 G 1⁄4 Interface Interface Interface Interface G 1⁄8 G 1⁄8 G 1⁄8 G 1⁄8 CNOMO CNOMO CNOMO Interface Interface Interface Interface G 1⁄8 G 1⁄8 G 1⁄8 G 1⁄8 Orifice (mm) 1,5 2,0 2,5 1,5 2,0 2,5 2,0 2,5 3,0 1,0 1,5 2,0 2,5 1,0 1,5 2,0 2,5 1,5 2,0 2,5 1,0 1,5 2,0 2,5 1,0 1,5 2,0 2,5 Maximum Operating Pressure (bar) 16 16 14 16 16 14 16 14 7 16 13 10 4 16 16 13 4 13 10 4 16 13 10 4 16 13 10 4 Weight (kg) 0,20 0,20 0,20 0,24 0,24 0,24 0,32 0,32 0,32 0,20 0,20 0,20 0,20 0,24 0,24 0,24 0,24 0,30 0,30 0,30 0,20 0,20 0,20 0,20 0,24 0,24 0,24 0,24 Coil Assembly without terminal box V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04X286A–Q122* V04 Symbol 2 12 10 1 2 12 10 3 1 2 10 12 1 3 *Insert voltage code from Voltage Codes table page 5.4.042.03. All models are available without manual override. Change 10th digit to 1 e.g. V03X486J–B11*A. CNOMO versions are available with a push to operate spring return manual override. Change 10th digit to 3 e.g. V03X486J–B31*A. Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under ‘Technical Data’. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. N/ ** 5.4.042.02 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 4/97 V03, V04, V05 Series V05 Symbol 2 12 10 1 2 12 10 3 1 2 10 12 1 3 Model Type Base V05X286M–B63*A V05A286M–B63*A V05B286M–B43*A V05B286N–B43*A V05X486K–B63*A V05X486L–B63*A V05X486M–B63*A V05A486K–B63*A V05A486L–B63*A V05A486M–B63*A V05B486L–B43*A V05B486M–B43*A V05Y486K–B63*A V05Y486L–B63*A V05Y486M–B63*A V05X386K–B63*A V05X386L–B63*A V05X386M–B63*A V05A386K–B63*A V05A386L–B63*A V05A386M–B63*A Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Closed Normally Open Normally Open Normally Open Normally Open Normally Open Normally Open Interface G 1⁄8 G 1⁄4 G 1⁄4 Interface Interface Interface G 1⁄8 G 1⁄8 G 1⁄8 G 1⁄4 G 1⁄4 CNOMO CNOMO CNOMO Interface Interface Interface G 1⁄8 G 1⁄8 G 1⁄8 Orifice (mm) 2,5 2,5 2,5 3,0 1,5 2,0 2,5 1,5 2,0 2,5 2,0 2,5 1,5 2,0 2,5 1,5 2,0 2,5 1,5 2,0 2,5 Maximum Operating Pressure (bar) 16 16 16 13 16 13 10 16 13 10 13 10 16 13 10 16 13 10 16 13 10 Weight (kg) 0,20 0,24 0,32 0,32 0,20 0,20 0,20 0,24 0,24 0,24 0,24 0,24 0,30 0,30 0,30 0,20 0,20 0,20 0,24 0,24 0,24 Coil Assembly without plug V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* V05X286A–Q123* *Insert voltage code from Voltage Codes table page 5.4.042.03. All models are available without manual override. Change 10th digit to 1 e.g. V03X486J–B11*A. CNOMO versions are available with a push to operate spring return manual override. Change 10th digit to 3 e.g. V03X486J–B31*A. Valve and Base Options Family V03 V04 V05 7mm Interface Mounted Valve V03X V04X V05X G1⁄8 Valve V03A V04A V05A G1⁄4 Valve V03B V04B V05B CNOMO Mounted Valve V03Y V04Y V05Y Fixed Length Manifold M/P35598/† M/P35598/† M/P35598/† *Insert Voltage Code from table below * Voltage Codes Manifold/Valve Assemblies V03X∆86∆-H613A# VO4X∆86∆-H62*A# VO5X∆86∆-H63*A# †Insert number of stations Technical Details Voltage 6 V d.c. 12 V d.c. 24 V d.c. 48 V d.c. 110 V d.c. 24 V 50/60 Hz 48 V 50/60 Hz 110 – 120 V 50/60 Hz 220 – 240 V 50/60 Hz Voltage Tolerance: Inrush/Hold Codes 1 2 3 5 7 4 6 8 9 ±10% V03 VO4 VO5 Plug: Manual Override Protection Class: d.c. 1,0 W d.c. 4,5 W a.c. 14/10 VA d.c. 9,0 W a.c. 27/20 VA 100% E.D. A variety of plugs are available, see Section 7.7.001 Screwdriver operated, memory type, standard IP 65 (DIN 40 050) with terminal box fitted Note: The V03 models are only available with the 24 V d.c. coil. Flow Characteristics Inlet Orifice ∆mm 1 1,5 2 2,5 3,0 C b l/min A Cv Kv 0,15 0,30 0,57 0,77 1,16 0,61 0,36 0,30 0,30 0,49 39,4 68,95 137,9 187,15 275,8 0,95 1,26 2,36 3,05 6,25 0,04 0,07 0,14 0,19 0,28 0,03 0,06 0,12 0,16 0,24 The above figures are based on valves mounted on a G1⁄8 base. They are typical of all base styles as the orifice diameter is the limiting factor. 4/97 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. N/ ** 5.4.042.03 V03, V04, V05 Series V 0 ★ ★ ★ 8 6 ★ - B ★ ★ ★ ★ Model Codes Family VO3 VO4 VO5 Substitute 3 4 5 Plug None Standard, with Pg9 cable gland Indicator, with Pg9 cable gland Base Type Interface CNOMO G1/8 G1/4 Substitute X Y A B Voltage code See Voltage Code table on page 3 Function 2/2 Normally closed 3/2 Normally open 3/2 Normally closed Substitute 2 3 4 Power 1W (VO3 models only) 4,5W (VO4 models only) 9W (VO5 models only) Substitute 1 2 3 Substitute 1 3* 4 6* Solenoid operator All Valves 8 Manual Operator None Push to operate spring return Lever, memory type Screwdriver, memory type Spring return All Valves 6 Integral design All Valves Inlet Orifice 1,0 mm (Interface, CNOMO) 1,5 mm (Interface, CNOMO, G1/8) 2,0 mm (Interface, CNOMO, G1/8, G1/4) 2,5 mm (Interface, CNOMO, G1/8, G1/4) 3,0 mm (G1/4) Substitute J K L M N B * Not available on G1⁄4 Note: This table should be used for identification purposes only and not to build up model variants. V03A, V04A and V05A Models G1⁄8 Valves V03X, V04X and V05X Models Interface Mounted Valves 32 32 7 ‘2’ 24 ‘1’ G1/8 2,4 24 24 32 3,3 7,5 32 6 M4 5 24 4,7 Substitute A B G 2,7 7 ‘2’ G1/8 9,3 7 ‘1’ 2,4 41 ‘3’ G1/8 41 12,5 8 7 63,5 74 59,5 70 6 6 ‘3’ G1/8 ‘1’ G1/8 2 1,5 2 40 40 69 69 N/ ** 5.4.042.04 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 4/97 V03, V04, V05 Series V03Y, V04Y and V05Y Models CNOMO Mounted Valves V03B, V04B and V05B Models G1⁄4 Valves 12,7 M4 12,7 21 M4 32 8 ‘2’ G1/4 41 41 79 68,5 ‘1’ G1/4 7,5 ‘2’ 17 19 12 21 7,5 72,5 83 6 ‘3’ G1/8 2 36 32 33 50 ‘1’ 41 40 70 69 Fixed Length Manifold 61** 61** 61** 4 M/P35598/* Weight = N x 0,041 Kg G1⁄8 N = Number of stations * indicates the number of stations (1 – 20) 4 4 24 ** M5 x 0,8 ** ‘2’ 16 ‘2’ ‘2’ 33 33 ‘2’ G1/8 x 9,5 33 x (N –1) + 32 N = Number of stations ** Two additional holes with five or more stations 4/97 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. N/ ** 5.4.042.05 V03, V04, V05 Series Manifold/Valve Assemblies 61** Interface mounted valves can be supplied pre-assembled on manifolds. 61** 4 Select the basic valve required and quote the associated manifold/valve assembly model using the table below. 4 "A" Basic Valve Model ‘1’ 24 ** ** V03 G1/8 M5 View on arrow "A" V04 ‘3’ G1/8 69 6 41 8,6 16 ‘2’ ‘2’ 33 33 ‘2’ G1/8 33 x (N* –1) + 32 13,2 17,2 ‘2’ 95,7 59,5 V05 V03X286J–B613A V03X486J–B613A V03X486K–B613A VO4X286K–B62*A VO4X286L–B62*A VO4X286M–B62*A VO4X486J–B62*A VO4X486K–B62*A VO4X486L–B62*A VO4X486M–B62*A VO5X286M–B61*A VO5X486K–B61*A VO5X486L–B61*A Manifold/Valve Assembly Model V03X286J–H613A# V03X486J–H613A# V03X486K–H613A# VO4X286K–H62*A# VO4X286L–H62*A# VO4X286M–H62*A# VO4X486J–H62*A# VO4X486K–H62*A# VO4X486L–H62*A# VO4X486M–H62*A# VO5X286M–H63*A# VO5X486K–H63*A# VO5X486L–H63*A# # Insert number of stations (1 - 20 stations) 1 = 1 station 2 = 2 station A = 10 station B = 11 station K = 19 Station L = 20 station * Insert Voltage Code from page 5.4.042.03 32,7 Options and Accessories Light Emitting Gaskets Voltage Range Model Number 12 – 24 V a.c./d.c. M/P40861 0,25 W 110 – 120 V a.c./d.c. M/P40880 0,25 W 220 – 240 V a.c./d.c. M/P40862 0,25 W N/ ** 5.4.042.06 Power consumption Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 4/97