ETC VO85516A

Nugget 40
V08 Series
Integrally Ported 5/2 and 5/3 Spool Valves
Solenoid Actuated and Pilot Operated
Ø 4, Ø 6mm or M5
● High flow from 17 mm body width
● Low power solenoids with a range of voltages
● Use valves singly or with Base Systems
● Low profile fixed length manifolds
● Modular manifolds can be DIN rail or surface mounted
Technical Data
Ordering Information
Medium:
Compressed air, filtered to 40µm lubricated and non-lubricated
Operation:
Spool valve, indirectly actuated
Mounting:
Through-holes in valve body or to 35 mm DIN rail using modular
base system
Port Sizes:
M5, Ø 4 mm and Ø 6 mm (with connector blocks)
Operating Pressure:
Maximum 10 bar
See individual details overleaf
Flow Characteristics:
Size
Function ‘C’
‘b’
‘A’
l/min Cv
Kv
M5
5/2
1
0,55
4,23
256
0,26 0,22
Ø 4mm 5/2
0,9
0,54
3,74
226
0,23 0,2
Ø 6mm 5/2
1,4
0,42
5,7
344
0,35 0,3
M5
5/3 APB 1,22 0,32
4,89
296
0,3
0,26
To order, quote model number and voltage code
from tables overleaf, e.g. V085516A–B213A for a
Solenoid Pilot Actuated, Spring and Air Return
model fitted with a 24 V d.c. coil and screwdriver
operated manual override.
Ambient Temperature:
-20˚C to +80˚C Pilot Models
-20˚C to +50˚C Solenoid Models
*Consult our Technical Service for use below +2˚C
Materials
Zinc alloy body, glass filled end caps, aluminium spool with
bonded nitrile rubber seals, and glass filled co-polymer bases.
Multipole Systems
For complete Valve Islands see section 5.4.112
5/2
5/2 Twin Supply
5/3
All ports blocked mid
position
5/3
Centre open exhaust
mid position
5/3 Centre open
pressure mid position
14
5
02/97
2
4
1
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
12
3
N/** 5.4.105.01
Nugget 40, V08 Series
General Information
5/2 Solenoid Actuated Valves
Symbol
4
2
5 1
3
14
Model
Manual
Overide
V085516A–B21*A
Screwdriver Bi-stable
V085516A–B31*A
Push Only
V085511A–B21*A
Screwdriver Bi-stable
V085511A–B31*A
Push Only
12
4
2
12
14
5 1
3
Solenoid
Pilot
Operator
Return
Operating
Pressure (bar)
Pilot
Pressure (bar)
Weight
(kg)
Spares kit
Internal
Solenoid
Spring and Air
3 – 10
–
0,155
V10034–K00
Internal
Solenoid
Solenoid
2 – 10
–
0,198
V10034–K00
*Insert voltage code from table below.
5/3 Solenoid Actuated Valves
Symbol
4
14
84
4
14
84
4
14
84
V085611A–B21*A
Screwdriver Bi-stable
3
V085611A–B31*A
Push Button
12
V085711A–B21*A
Screwdriver Bi-stable
3
82
V085711A–B31*A
Push Button
12
V085811A–B21*A
Screwdriver Bi-stable
82
V085811A–B31*A
Push Button
2
1
5
12
82
2
1
5
Manual
Overide
2
1
5
Model
3
Pilot
Supply
Operator
Mid
Position
Return
Operating
Pressure (bar)
Pilot
Pressure (bar)
Weight
(kg)
Spares kit
Internal
Solenoid
APB
Solenoid
-0,9 – 10
–
0,158
V10034–K01
Internal
Solenoid
COE
Solenoid
-0,9 – 10
–
0,158
V10034–K02
Internal
Solenoid
COP
Solenoid
-0,9 – 10
–
0,158
V10034–K03
*Insert voltage code from table below.
Pilot Actuated Valves
Symbol
4
2
5 1
3
4
2
5 1
3
14
12
12
14
4
Model
Manual
Override
Operator
MidPosition
Return
Operating
Pressure (bar)
Pilot
Pressure (bar)
Weight
(kg)
Spares kit
V085536A–X0130
–
Pressure
-
Spring and Air
2 - 10
1,5 + 0,5
x supply
0,152
V10034-K00
V085533A–X0020
–
Pressure
-
Pressure
1 - 10
2 - 10
0,141
V10034-K00
V085633A–X0020
–
Pressure
APB
Spring and Air
1 - 10
Minimum
2 bar
0,119
V10034-K01
V085733A-X0020
–
Pressure
COE
Spring and Air
1 - 10
Minimum
2 bar
0,119
V10034-K02
V085833A-X0020
–
Pressure
COP
Spring and Air
1 - 10
Minimum
2 bar
0,119
V10034-K03
V085533A-X0060
–
Pilot Priority
–
Pilot
-0,9 - 10
Minimum
2 bar
0,119
V10034-K00
2
14
12
1
5
4
3
2
14
12
5
1
4
3
2
14
12
5
1
3
4
2
12
14
5
1
3
APB = All Ports Blocked, COE = Centre Open Exhaust, COP = Centre Open Pressure.
Electrical Details for Solenoid Operators
*Voltage Codes and Spare Coils
Voltage
6V d.c.
12V d.c.
24V d.c.
12V 50/60Hz
24V 50/60Hz
48V 50/60Hz
110V 50/60Hz
240V 50/60Hz
Codes
1
2
3
1
4
6
8
9
Power Inrush/Hold
1,5 W
1,7 W
1,7 W
4,1/2,9 VA
4,1/2,9 VA
4,1/2,9 VA
3,5/2,5 VA
3,5/2,5 VA
Coil Part Number
V10025-A11
V10025-A12
V10025-A13
V10025-A11
V10025-A14
V10025-A16
V10025-A18
V10025-A19
Voltage Tolerances:
Rating:
Inlet Orifice:
Electrical Connection:
Manual Override:
Protection Class:
±10%
100% E.D.
0,8 mm
DIN 43650 table ‘C’
V0855--A–B21*A – Screwdriver Bi-stable
V0855--A–B31*A – Push button, spring return
IP 65 (DIN 40050)
For details of connector plugs and light emitting seals see section 7.7.001.
Accessories
Optional Port Connector Blocks
V085516A–Q0404, Ø4 mm
V085516A–Q0404, Ø6 mm
N/** 5.4.105.02
Blanking Plate
VO95516A–Q1100
–
Optional Tie Rod Kits
V085516A–Q0302–0316
–
DIN Rail
V10009–C00 1 metre
–
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
Blanking Plug
V10511–K01
–
02/97
Nugget 40, V08 Series
V085516A Models
5/2 Single Solenoid Valve
V085511A Models
5/2 Double Solenoid Valve
156
109
65
12
12
11
11
65
Ø2,5
6
47
‘14’
‘12’
‘5’
‘1’
M5 x 0,8
M5 x 0,8
24
24
71
71
142
101
65
65
12
Ø2,7
Manual
Override
1,4
‘4’
‘2’
Manual
Override
6
63,25
8,5
17
‘2’
12,5
1,4
8,5
‘4’
12,5
12
M5 x 0,8
M5 x 0,8
17
‘3’
25
‘3’
8
‘1’
25
‘12’
‘5’
8
29
‘14’
29
6
47
Ø2,5
63,25
16,5
Ø2,7
6
Manual
Override
16,5
V085*11A-B21*A Model
5/3 Double Solenoid Valve
171
6
8
'14'
'12'
'5' '1' '3'
25
29
47
11
Manual Override
M5x0,8
24
71
157
12
65
6
63,25
02/97
1,4
12,5
8,5
17
M5x0,8
16,5
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
UK/** 5.4.105.03
Nugget 40, V08 Series
V085536A–X0130 Model
5/2 Single Pilot Valve
12
23,5
M5
5
1
12
3
M5
8,5
24
8,5
24
30
30
60,5
24
61,5
12
24
12
17
4
2
4
12,5
17
1,4
M5
1,4
M5
12,5
12,5
14
8
12
3
6
12,5
1
8
5
M5x0.8
Ø2,5
6
25
14
12
M5x0.8
Ø2,5
25
23,5
V085533A–X0020 and V085533A–X0060
5/2 Double Pilot Valves
2
Ø2,7
Ø2,7
6
6
21,8
16,5
16,5
22,5
V085*33A-X0020 Model
5/3 Double Pilot Valve
'14'
'12'
'5'
8
6
25
12,5
M5x0.8
'1'
'3'
8,5
M5x0,8
24
30
75
12
24
4
12,5
17
M5x0,8
2
6
16,5
N/** 5.4.105.04
36,5
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
02/97
Nugget 40 V08 Series
Modular Manifold for DIN rail or surface mounting
156
Manifold Block (A)
11
Position indicators
V085516A–Q01A8
Single Station Manifold Block
‘C’
End Plate Kit (B)
‘12’
‘14’
26
‘3/5’
‘1’
1
6
40
78
79
V085516A–Q02A8
Consisting of 1 left hand and 1 right hand end cap with
push-in connectors and DIN rail mounting system
Size: Ø 8 mm tube
62
Optional Port Connector Blocks (C)
45
Push-in port connector block with integral position
indicators
V085516A–Q0404
Size: Ø 4 mm tube
V085516A–Q0406
Size: Ø 6 mm tube
45
18
9
‘3/5’
‘B’
‘1’
18
‘4’
‘2’
Tie Rod Kits
‘2’
V085516A–Q03**
** = Number of stations in manifold, 02 to 16.
(N x 18) + 36
‘4’
‘4’
‘2’
‘A’
‘4’
‘2’
‘1’
‘B’
9
‘3/5’
Pillar screws supplied as standard with Manifold Blocks
and End Plate kits. Tie Rod Kits are an optional extra.
8
23
16
N = Number of stations
Modular Manifold assemblies for DIN rail or surface mounting
26
3/5
V088AX**–XXXXX
Manifold assemblies for 2 to 16 stations, ** = 02 to 16.
Size: Ø 8 mm tube
1
1
6
40
Modular Manifold Assemblies
62
Right hand end
Dual Pressure Modular Manifold assemblies
45
(N* x 18) + 36
18
18
9
V088AX**–**XXX
Manifold assemblies for 2 to 16 stations, allows supply of
two different inlet pressures simultaneously
Size: Ø 8 mm tube
** = 1 to 15 to indicate position of Dual Pressure Plug, e.g
V088AX03–07XX indicates a 10 station base divided into
groups of 3 and 7.
Dual Pressure Plug
9
9
V085516A–Q05AA
To be placed in the inlet gallery
***
23
16
N = Number of stations
02/97
Left hand end
15
*** For ∅8 mm tube
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
UK/** 5.4.105.05
Nugget 40 V08 Series
Type
V10026 – G02
V10026 – G04
V10026 – G06
V10026 – G08
V10026 – G10
V10026 – G12
Fixed Length Manifold
G1/8
5
A
58
94
130
166
202
238
33
1
1
Note: Gaskets and valve fixing screws are supplied with
these manifolds.
3
3
49
16,5
4
5
5
A
5
No. of stations
2
4
6
8
10
12
18.5
18
21,5
9
17,5
Ø6
Blanking Plugs
V10511-K01
For dual pressure supply on Fixed Length Manifold.
14
27,5
Blanking Plate
V095516A–Q1100
Blanking Plate for blocking off unwanted stations.
17
12,5
38
5
5
1
11
M2,5
Accessories
Connector plugs and light emitting seals see section 7.7.001.
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can
exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider
the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to
equipment in the event of such failure.
System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.
N/** 5.4.105.06
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
02/97