Nugget 40 V08 Series Integrally Ported 5/2 and 5/3 Spool Valves Solenoid Actuated and Pilot Operated Ø 4, Ø 6mm or M5 ● High flow from 17 mm body width ● Low power solenoids with a range of voltages ● Use valves singly or with Base Systems ● Low profile fixed length manifolds ● Modular manifolds can be DIN rail or surface mounted Technical Data Ordering Information Medium: Compressed air, filtered to 40µm lubricated and non-lubricated Operation: Spool valve, indirectly actuated Mounting: Through-holes in valve body or to 35 mm DIN rail using modular base system Port Sizes: M5, Ø 4 mm and Ø 6 mm (with connector blocks) Operating Pressure: Maximum 10 bar See individual details overleaf Flow Characteristics: Size Function ‘C’ ‘b’ ‘A’ l/min Cv Kv M5 5/2 1 0,55 4,23 256 0,26 0,22 Ø 4mm 5/2 0,9 0,54 3,74 226 0,23 0,2 Ø 6mm 5/2 1,4 0,42 5,7 344 0,35 0,3 M5 5/3 APB 1,22 0,32 4,89 296 0,3 0,26 To order, quote model number and voltage code from tables overleaf, e.g. V085516A–B213A for a Solenoid Pilot Actuated, Spring and Air Return model fitted with a 24 V d.c. coil and screwdriver operated manual override. Ambient Temperature: -20˚C to +80˚C Pilot Models -20˚C to +50˚C Solenoid Models *Consult our Technical Service for use below +2˚C Materials Zinc alloy body, glass filled end caps, aluminium spool with bonded nitrile rubber seals, and glass filled co-polymer bases. Multipole Systems For complete Valve Islands see section 5.4.112 5/2 5/2 Twin Supply 5/3 All ports blocked mid position 5/3 Centre open exhaust mid position 5/3 Centre open pressure mid position 14 5 02/97 2 4 1 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 12 3 N/** 5.4.105.01 Nugget 40, V08 Series General Information 5/2 Solenoid Actuated Valves Symbol 4 2 5 1 3 14 Model Manual Overide V085516A–B21*A Screwdriver Bi-stable V085516A–B31*A Push Only V085511A–B21*A Screwdriver Bi-stable V085511A–B31*A Push Only 12 4 2 12 14 5 1 3 Solenoid Pilot Operator Return Operating Pressure (bar) Pilot Pressure (bar) Weight (kg) Spares kit Internal Solenoid Spring and Air 3 – 10 – 0,155 V10034–K00 Internal Solenoid Solenoid 2 – 10 – 0,198 V10034–K00 *Insert voltage code from table below. 5/3 Solenoid Actuated Valves Symbol 4 14 84 4 14 84 4 14 84 V085611A–B21*A Screwdriver Bi-stable 3 V085611A–B31*A Push Button 12 V085711A–B21*A Screwdriver Bi-stable 3 82 V085711A–B31*A Push Button 12 V085811A–B21*A Screwdriver Bi-stable 82 V085811A–B31*A Push Button 2 1 5 12 82 2 1 5 Manual Overide 2 1 5 Model 3 Pilot Supply Operator Mid Position Return Operating Pressure (bar) Pilot Pressure (bar) Weight (kg) Spares kit Internal Solenoid APB Solenoid -0,9 – 10 – 0,158 V10034–K01 Internal Solenoid COE Solenoid -0,9 – 10 – 0,158 V10034–K02 Internal Solenoid COP Solenoid -0,9 – 10 – 0,158 V10034–K03 *Insert voltage code from table below. Pilot Actuated Valves Symbol 4 2 5 1 3 4 2 5 1 3 14 12 12 14 4 Model Manual Override Operator MidPosition Return Operating Pressure (bar) Pilot Pressure (bar) Weight (kg) Spares kit V085536A–X0130 – Pressure - Spring and Air 2 - 10 1,5 + 0,5 x supply 0,152 V10034-K00 V085533A–X0020 – Pressure - Pressure 1 - 10 2 - 10 0,141 V10034-K00 V085633A–X0020 – Pressure APB Spring and Air 1 - 10 Minimum 2 bar 0,119 V10034-K01 V085733A-X0020 – Pressure COE Spring and Air 1 - 10 Minimum 2 bar 0,119 V10034-K02 V085833A-X0020 – Pressure COP Spring and Air 1 - 10 Minimum 2 bar 0,119 V10034-K03 V085533A-X0060 – Pilot Priority – Pilot -0,9 - 10 Minimum 2 bar 0,119 V10034-K00 2 14 12 1 5 4 3 2 14 12 5 1 4 3 2 14 12 5 1 3 4 2 12 14 5 1 3 APB = All Ports Blocked, COE = Centre Open Exhaust, COP = Centre Open Pressure. Electrical Details for Solenoid Operators *Voltage Codes and Spare Coils Voltage 6V d.c. 12V d.c. 24V d.c. 12V 50/60Hz 24V 50/60Hz 48V 50/60Hz 110V 50/60Hz 240V 50/60Hz Codes 1 2 3 1 4 6 8 9 Power Inrush/Hold 1,5 W 1,7 W 1,7 W 4,1/2,9 VA 4,1/2,9 VA 4,1/2,9 VA 3,5/2,5 VA 3,5/2,5 VA Coil Part Number V10025-A11 V10025-A12 V10025-A13 V10025-A11 V10025-A14 V10025-A16 V10025-A18 V10025-A19 Voltage Tolerances: Rating: Inlet Orifice: Electrical Connection: Manual Override: Protection Class: ±10% 100% E.D. 0,8 mm DIN 43650 table ‘C’ V0855--A–B21*A – Screwdriver Bi-stable V0855--A–B31*A – Push button, spring return IP 65 (DIN 40050) For details of connector plugs and light emitting seals see section 7.7.001. Accessories Optional Port Connector Blocks V085516A–Q0404, Ø4 mm V085516A–Q0404, Ø6 mm N/** 5.4.105.02 Blanking Plate VO95516A–Q1100 – Optional Tie Rod Kits V085516A–Q0302–0316 – DIN Rail V10009–C00 1 metre – Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. Blanking Plug V10511–K01 – 02/97 Nugget 40, V08 Series V085516A Models 5/2 Single Solenoid Valve V085511A Models 5/2 Double Solenoid Valve 156 109 65 12 12 11 11 65 Ø2,5 6 47 ‘14’ ‘12’ ‘5’ ‘1’ M5 x 0,8 M5 x 0,8 24 24 71 71 142 101 65 65 12 Ø2,7 Manual Override 1,4 ‘4’ ‘2’ Manual Override 6 63,25 8,5 17 ‘2’ 12,5 1,4 8,5 ‘4’ 12,5 12 M5 x 0,8 M5 x 0,8 17 ‘3’ 25 ‘3’ 8 ‘1’ 25 ‘12’ ‘5’ 8 29 ‘14’ 29 6 47 Ø2,5 63,25 16,5 Ø2,7 6 Manual Override 16,5 V085*11A-B21*A Model 5/3 Double Solenoid Valve 171 6 8 '14' '12' '5' '1' '3' 25 29 47 11 Manual Override M5x0,8 24 71 157 12 65 6 63,25 02/97 1,4 12,5 8,5 17 M5x0,8 16,5 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. UK/** 5.4.105.03 Nugget 40, V08 Series V085536A–X0130 Model 5/2 Single Pilot Valve 12 23,5 M5 5 1 12 3 M5 8,5 24 8,5 24 30 30 60,5 24 61,5 12 24 12 17 4 2 4 12,5 17 1,4 M5 1,4 M5 12,5 12,5 14 8 12 3 6 12,5 1 8 5 M5x0.8 Ø2,5 6 25 14 12 M5x0.8 Ø2,5 25 23,5 V085533A–X0020 and V085533A–X0060 5/2 Double Pilot Valves 2 Ø2,7 Ø2,7 6 6 21,8 16,5 16,5 22,5 V085*33A-X0020 Model 5/3 Double Pilot Valve '14' '12' '5' 8 6 25 12,5 M5x0.8 '1' '3' 8,5 M5x0,8 24 30 75 12 24 4 12,5 17 M5x0,8 2 6 16,5 N/** 5.4.105.04 36,5 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 02/97 Nugget 40 V08 Series Modular Manifold for DIN rail or surface mounting 156 Manifold Block (A) 11 Position indicators V085516A–Q01A8 Single Station Manifold Block ‘C’ End Plate Kit (B) ‘12’ ‘14’ 26 ‘3/5’ ‘1’ 1 6 40 78 79 V085516A–Q02A8 Consisting of 1 left hand and 1 right hand end cap with push-in connectors and DIN rail mounting system Size: Ø 8 mm tube 62 Optional Port Connector Blocks (C) 45 Push-in port connector block with integral position indicators V085516A–Q0404 Size: Ø 4 mm tube V085516A–Q0406 Size: Ø 6 mm tube 45 18 9 ‘3/5’ ‘B’ ‘1’ 18 ‘4’ ‘2’ Tie Rod Kits ‘2’ V085516A–Q03** ** = Number of stations in manifold, 02 to 16. (N x 18) + 36 ‘4’ ‘4’ ‘2’ ‘A’ ‘4’ ‘2’ ‘1’ ‘B’ 9 ‘3/5’ Pillar screws supplied as standard with Manifold Blocks and End Plate kits. Tie Rod Kits are an optional extra. 8 23 16 N = Number of stations Modular Manifold assemblies for DIN rail or surface mounting 26 3/5 V088AX**–XXXXX Manifold assemblies for 2 to 16 stations, ** = 02 to 16. Size: Ø 8 mm tube 1 1 6 40 Modular Manifold Assemblies 62 Right hand end Dual Pressure Modular Manifold assemblies 45 (N* x 18) + 36 18 18 9 V088AX**–**XXX Manifold assemblies for 2 to 16 stations, allows supply of two different inlet pressures simultaneously Size: Ø 8 mm tube ** = 1 to 15 to indicate position of Dual Pressure Plug, e.g V088AX03–07XX indicates a 10 station base divided into groups of 3 and 7. Dual Pressure Plug 9 9 V085516A–Q05AA To be placed in the inlet gallery *** 23 16 N = Number of stations 02/97 Left hand end 15 *** For ∅8 mm tube Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. UK/** 5.4.105.05 Nugget 40 V08 Series Type V10026 – G02 V10026 – G04 V10026 – G06 V10026 – G08 V10026 – G10 V10026 – G12 Fixed Length Manifold G1/8 5 A 58 94 130 166 202 238 33 1 1 Note: Gaskets and valve fixing screws are supplied with these manifolds. 3 3 49 16,5 4 5 5 A 5 No. of stations 2 4 6 8 10 12 18.5 18 21,5 9 17,5 Ø6 Blanking Plugs V10511-K01 For dual pressure supply on Fixed Length Manifold. 14 27,5 Blanking Plate V095516A–Q1100 Blanking Plate for blocking off unwanted stations. 17 12,5 38 5 5 1 11 M2,5 Accessories Connector plugs and light emitting seals see section 7.7.001. Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under ‘Technical Data’. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. N/** 5.4.105.06 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 02/97