BRAIN DIA53S724

Monitoring Relays
1-Phase AC Over Current
Type DIA53S
Product Description
Compact current monitoring relay with built-in current transformer with adjustable set-point and integrated solid state
output. Self-powered and 2-wire connection for easy use.
12 mm hole for insulate current carrying wire makes it suitable for most applications. For mounting on DIN-rail.
17.5 mm wide housing suitable both for back and front
panel mounting.
Property
•
•
•
•
•
•
•
•
2-wire connection
Self-powered
Input ranges: 2 - 20 AAC, 5 - 50 AAC or 10 - 100 AAC
Knob-adjustable set-point
Output: Normally open, 100 mA
LED indication for output ON
17.5 mm DIN-rail housing (DIN 43880)
For mounting on DIN-rail in accordance
with DIN/EN50022
Type Selection
Output Specifications
Input current
Reaction time
Type no.
Output
2 - 20 AAC
5 - 50 AAC
10 - 100 AAC
2 - 20 AAC
5 - 50 AAC
10 - 100 AAC
Standard
Standard
Standard
Fast
Fast
Fast
DIA53 S724 20A
DIA53 S724 50A
DIA53 S724 100A
DIA53 S724 20AF
DIA53 S724 50AF
DIA53 S724 100AF
Output current
Maximum load current
Leakage current
Max. voltage
Voltage drop (Ud)
NPN-PNP open collector,
NO
100 mA
≤ 100 μA
40 VDC
< 2.5 VDC
Input Specifications
Current range
Max. current (continuously)
Max. overload current
(t = 30 s)
DIA53 S 724 20A/...AF
DIA53 S 724 50A/...AF
DIA53 S 724 100A/...AF
2 - 20 AAC @ 50 Hz
40 AAC
5 - 50 AAC @ 50 Hz
100 AAC
10 - 100 AAC @ 50 Hz
150 AAC
200 AAC
200 AAC
200 AAC
General Specifications
Reaction time
DIA53
DIA53...F
Repeatability
Hysteresis
(Differential travel)
Frequency range
Temperature variation
Environment
Degree of protection
Pollution degree
Operating temperature
< 300 ms
(input signal variation from
-20% to +20% of set value)
< 50 ms
(input signal variation from
-20% to +20% of set value)
0.5 %
7 - 13% of setpoint
45 - 400 Hz
±0.20%/°C of setpoint
IP 20
3
-20 to +60°C
Weight
Screw terminals
Tightening torque
Housing
Dimensions
Material
Product standard
Approval
CE Marking
EMC
Immunity
Emissions
www.dold-relay.com
80 g
Max. 0.5 Nm
acc. to IEC 60947
17.5 x 81 x 67.2 mm
PA66 or Noryl
EN 60255-6
UL, CSA
L.V. Directive 2006/95/EC
EMC Directive 2004/108/EC
According to EN 60255-26
According to EN 61000-6-2
According to EN 60255-26
According to EN 61000-6-3
1
DIA53S
Wiring Diagrams
Dimensions
17.5
Set level
67.2
18.7
Hysteresis
1
Output ON
LED ON
2
2
2
www.dold-relay.com
35.5
81
ø 12
45
Operation Diagram
Monitoring Relays
1-Phase AC Over Current
Type DIA53C
Product Description
Compact current monitoring relay with built-in current trans-
former with adjustable set-point and integrated solid state
output. Self-powered and 2-wire connection for easy use.
12 mm hole for insulate current carrying wire makes it suit-
able for most applications. For mounting on DIN-rail.
17.5 mm wide housing suitable both for back and front
panel mounting.
Property
•
•
•
•
•
•
•
2-wire connection
Self-powered
Input ranges: 2 - 20 AAC, 5 - 50 AAC or 10 - 100 AAC
Knob-adjustable set-point
Output: Normally open, 800 mA
LED indication for output ON
For mounting on DIN-rail in accordance with
DIN/EN50022
• 17.5 mm DIN-rail housing (DIN 43880)
Type Selection
Input current
2 - 20 AAC
5 - 50 AAC
10 - 100 AAC
2 - 20 AAC
5 - 50 AAC
10 - 100 AAC
Output Specifications
Reaction time
Standard
Standard
Standard
Fast
Fast
Fast
Type no.
DIA53 C724 20A
DIA53 C724 50A
DIA53 C724 100A
DIA53 C724 20AF
DIA53 C724 50AF
DIA53 C724 100AF
Input Specifications
Current range
Max. current (continuously)
Max. overload current
(t = 30 s)
Output
S.C.R. NO
Output current
Minimum load current
Leakage current
Min. off state voltage
Voltage drop (Ud)
800 mA
≤ 100 μA
400 VAC
< 1.5 VAC
Max. holding current
5 mA
Max. latching current
6 mA
Critical dv/dt
100V/us
Critical di/dt
30A/us
Fusing current (I2 t)
0.32A2 s
DIA53 C 724 20A/...AF
DIA53 C 724 50A/...AF
DIA53 C 724 100A/...AF
2 - 20 AAC @ 50 Hz
40 AAC
5 - 50 AAC @ 50 Hz
100 AAC
10 - 100 AAC @ 50 Hz
150 AAC
200 AAC
200 AAC
200 AAC
General Specifications
Reaction time
DIA53
DIA53...F
Repeatability
Hysteresis
(Differential travel)
Frequency range
Temperature variation
Environment
Degree of protection
Pollution degree
Operating temperature
< 300 ms
(input signal variation from
-20% to +20% of set value)
< 50 ms
(input signal variation from
-20% to +20% of set value)
0.5 %
7 - 13% of setpoint
45 - 400 Hz
±0.20%/°C of setpoint
IP 20
3
-20 to +60°C
Weight
Screw terminals
Tightening torque
Housing
Dimensions
Material
Product standard
Approval
CE Marking
EMC
Immunity
Emissions
www.dold-relay.com
80 g
Max. 0.5 Nm
acc. to IEC 60947
17.5 x 81 x 67.2 mm
PA66 or Noryl
EN 60255-6
UL, CSA
L.V. Directive 2006/95/EC
EMC Directive 2004/108/EC
According to EN 60255-26
According to EN 61000-6-2
According to EN 60255-26
According to EN 61000-6-3
3
DIA53C
Wiring Diagrams
Dimensions
17.5
Set level
67.2
18.7
Hysteresis
1
Output ON
LED ON
2
2
4
www.dold-relay.com
35.5
81
ø 12
45
Operation Diagram
Monitoring Relays
1-Phase AC Over Current
Type DIA53R1
Product Description
Compact current monitoring relay with built-in current trans-
former with adjustable set-point and 5A SPDT DC relay output. Industrial standard DC power supply for easy use.
12 mm hole for insulate current carrying wire makes it suit-
able for most applications. For mounting on DIN-rail.
17.5 mm wide housing suitable both for back and front
panel mounting.
Property
•
•
•
•
•
•
Input ranges: 2 - 20 AAC, 5 - 50 AAC or 10 - 100 AAC
Knob-adjustable set-point
Output: 5A SPDT relay normally de-energiZed
LED indication for output ON
For mounting on DIN-rail in accordance with
DIN/EN50022
17.5 mm DIN-rail housing (DIN 43880)
Type Selection
Input current
Reaction time
Type no.
2 - 20 AAC
5 - 50 AAC
10 - 100 AAC
2 - 20 AAC
5 - 50 AAC
10 - 100 AAC
Standard
Standard
Standard
Fast
Fast
Fast
DIA53 R1724 20A
DIA53 R1724 50A
DIA53 R1724 100A
DIA53 R1724 20AF
DIA53 R1724 50AF
DIA53 R1724 100AF
Input Specifications
Output Specifications
Output
Rated insulation voltage
Contact ratings (AgSnO2)
Resistive loads
AC 1
DC 12
Small inductive loads AC 15
DC 13
Mechanical life
Electrical life
SPDT relay, N.D.
250 VAC
μ
5 A @ 250 VAC
5 A @ 24 VDC
2.5 A @ 250 VAC
2.5 A @ 24 VDC
≥ 30 x 106 operations
≥ 105 operations
( at 5 A, 250 V, cos ϕ = 1)
≤ 7200 operations/h
Operating frequency
Dielectric strength
≥ 2 kVAC (rms)
Dielectric voltage
Rated impulse withstand volt. 4 kV (1.2/50 μs)
DIA53 R1 724 20A/...AF
DIA53 R1 724 50A/...AF
DIA53 R1 724 100A/...AF
Current range
Max. current (continuously)
Max. overload current
(t = 30 s)
2 - 20 AAC @ 50 Hz
40 AAC
5 - 50 AAC @ 50 Hz
100 AAC
10 - 100 AAC @ 50 Hz
150 AAC
200 AAC
200 AAC
200 AAC
Relay voltage
15 - 40 VDC
15 - 40 VDC
15 - 40 VDC
Relay consumption
≤ 220mw
≤ 220mw
≤ 220mw
General Specifications
Reaction time
DIA53
DIA53...F
Repeatability
Hysteresis
(Differential travel)
Frequency range
Temperature variation
Environment
Degree of protection
Pollution degree
Operating temperature
< 320 ms
(input signal variation from
-20% to +20% of set value)
< 70 ms
(input signal variation from
-20% to +20% of set value)
0.5 %
7 - 13% of setpoint
45 - 400 Hz
±0.20%/°C of setpoint
IP 20
3
-20 to +60°C
Weight
Screw terminals
Tightening torque
Housing
Dimensions
Material
Product standard
Approval
CE Marking
EMC
Immunity
Emissions
www.dold-relay.com
85 g
Max. 0.5 Nm
acc. to IEC 60947
17.5 x 81 x 67.2 mm
PA66 or Noryl
EN 60255-6
UL, CSA
L.V. Directive 2006/95/EC
EMC Directive 2004/108/EC
According to EN 60255-26
According to EN 61000-6-2
According to EN 60255-26
According to EN 61000-6-3
5
DIA53R1
Wiring Diagrams
Dimensions
17.5
67.2
18.7
2
Operation Diagram
Set level
Hysteresis
R elay voltage
R elay ON LED ON
5
www.dold-relay.com
45
35.5
81
ø 12
Monitoring Relays
1-Phase AC Over Current
Type DIA53R2
Product Description
Compact current monitoring relay with built-in current trans-
former with adjustable set-point and 5A SPDT AC relay output. Industrial standard AC power supply for easy use.
12 mm hole for insulate current carrying wire makes it suit-
able for most applications. For mounting on DIN-rail.
17.5 mm wide housing suitable both for back and front
panel mounting.
Property
•
•
•
•
•
•
Input ranges: 2 - 20 AAC, 5 - 50 AAC or 10 - 100 AAC
Knob-adjustable set-point
Output: 5A SPDT relay normally de-energiZed
LED indication for output ON
For mounting on DIN-rail in accordance with
DIN/EN50022
17.5 mm DIN-rail housing (DIN 43880)
Type Selection
Input current
Reaction time
Type no.
2 - 20 AAC
5 - 50 AAC
10 - 100 AAC
2 - 20 AAC
5 - 50 AAC
10 - 100 AAC
Standard
Standard
Standard
Fast
Fast
Fast
DIA53 R2724 20A
DIA53 R2724 50A
DIA53 R2724 100A
DIA53 R2724 20AF
DIA53 R2724 50AF
DIA53 R2724 100AF
Output Specifications
Output
Rated insulation voltage
Contact ratings (AgSnO2)
Resistive loads
AC 1
DC 12
Small inductive loads AC 15
DC 13
Mechanical life
Electrical life
SPDT relay, N.D.
250 VAC
μ
5 A @ 250 VAC
5 A @ 24 VDC
2.5 A @ 250 VAC
2.5 A @ 24 VDC
≥ 30 x 106 operations
≥ 105 operations
( at 5 A, 250 V, cos ϕ = 1)
≤ 7200 operations/h
Operating frequency
Dielectric strength
≥ 2 kVAC (rms)
Dielectric voltage
Rated impulse withstand volt. 4 kV (1.2/50 μs)
Input Specifications
DIA53 R2 724 20A/...AF
DIA53 R2 724 50A/...AF
DIA53 R2 724 100A/...AF
Current range
Max. current (continuously)
Max. overload current
(t = 30 s)
2 - 20 AAC @ 50 Hz
40 AAC
5 - 50 AAC @ 50 Hz
100 AAC
10 - 100 AAC @ 50 Hz
150 AAC
200 AAC
200 AAC
200 AAC
Relay voltage
Relay consumption(at 50Hz )
200 -240 VAC
≤ 0.75 VA
200 -240 VAC
≤ 0.75 VA
200 -240 VAC
≤ 0.75 VA
General Specifications
Reaction time
DIA53
DIA53...F
Repeatability
Hysteresis
(Differential travel)
Frequency range
Temperature variation
Environment
Degree of protection
Pollution degree
Operating temperature
< 320 ms
(input signal variation from
-20% to +20% of set value)
< 70 ms
(input signal variation from
-20% to +20% of set value)
0.5 %
7 - 13% of setpoint
45 - 400 Hz
±0.20%/°C of setpoint
IP 20
3
-20 to +60°C
Weight
Screw terminals
Tightening torque
Housing
Dimensions
Material
Product standard
Approval
CE Marking
EMC
Immunity
Emissions
85 g
Max. 0.5 Nm
acc. to IEC 60947
17.5 x 81 x 67.2 mm
PA66 or Noryl
EN 60255-6
UL, CSA
L.V. Directive 2006/95/EC
EMC Directive 2004/108/EC
According to EN 60255-26
According to EN 61000-6-2
According to EN 60255-26
According to EN 61000-6-3
www.dold-relay.com
7
DIA53R2
Wiring Diagrams
Dimensions
17.5
67.2
18.7
2
Operation Diagram
Set level
Hysteresis
R elay voltage
R elay ON LED ON
8
www.dold-relay.com
45
35.5
81
ø 12