Monitoring Relays 1-Phase AC Over Current Type DIA53S Product Description Compact current monitoring relay with built-in current transformer with adjustable set-point and integrated solid state output. Self-powered and 2-wire connection for easy use. 12 mm hole for insulate current carrying wire makes it suitable for most applications. For mounting on DIN-rail. 17.5 mm wide housing suitable both for back and front panel mounting. Property • • • • • • • • 2-wire connection Self-powered Input ranges: 2 - 20 AAC, 5 - 50 AAC or 10 - 100 AAC Knob-adjustable set-point Output: Normally open, 100 mA LED indication for output ON 17.5 mm DIN-rail housing (DIN 43880) For mounting on DIN-rail in accordance with DIN/EN50022 Type Selection Output Specifications Input current Reaction time Type no. Output 2 - 20 AAC 5 - 50 AAC 10 - 100 AAC 2 - 20 AAC 5 - 50 AAC 10 - 100 AAC Standard Standard Standard Fast Fast Fast DIA53 S724 20A DIA53 S724 50A DIA53 S724 100A DIA53 S724 20AF DIA53 S724 50AF DIA53 S724 100AF Output current Maximum load current Leakage current Max. voltage Voltage drop (Ud) NPN-PNP open collector, NO 100 mA ≤ 100 μA 40 VDC < 2.5 VDC Input Specifications Current range Max. current (continuously) Max. overload current (t = 30 s) DIA53 S 724 20A/...AF DIA53 S 724 50A/...AF DIA53 S 724 100A/...AF 2 - 20 AAC @ 50 Hz 40 AAC 5 - 50 AAC @ 50 Hz 100 AAC 10 - 100 AAC @ 50 Hz 150 AAC 200 AAC 200 AAC 200 AAC General Specifications Reaction time DIA53 DIA53...F Repeatability Hysteresis (Differential travel) Frequency range Temperature variation Environment Degree of protection Pollution degree Operating temperature < 300 ms (input signal variation from -20% to +20% of set value) < 50 ms (input signal variation from -20% to +20% of set value) 0.5 % 7 - 13% of setpoint 45 - 400 Hz ±0.20%/°C of setpoint IP 20 3 -20 to +60°C Weight Screw terminals Tightening torque Housing Dimensions Material Product standard Approval CE Marking EMC Immunity Emissions www.dold-relay.com 80 g Max. 0.5 Nm acc. to IEC 60947 17.5 x 81 x 67.2 mm PA66 or Noryl EN 60255-6 UL, CSA L.V. Directive 2006/95/EC EMC Directive 2004/108/EC According to EN 60255-26 According to EN 61000-6-2 According to EN 60255-26 According to EN 61000-6-3 1 DIA53S Wiring Diagrams Dimensions 17.5 Set level 67.2 18.7 Hysteresis 1 Output ON LED ON 2 2 2 www.dold-relay.com 35.5 81 ø 12 45 Operation Diagram Monitoring Relays 1-Phase AC Over Current Type DIA53C Product Description Compact current monitoring relay with built-in current trans- former with adjustable set-point and integrated solid state output. Self-powered and 2-wire connection for easy use. 12 mm hole for insulate current carrying wire makes it suit- able for most applications. For mounting on DIN-rail. 17.5 mm wide housing suitable both for back and front panel mounting. Property • • • • • • • 2-wire connection Self-powered Input ranges: 2 - 20 AAC, 5 - 50 AAC or 10 - 100 AAC Knob-adjustable set-point Output: Normally open, 800 mA LED indication for output ON For mounting on DIN-rail in accordance with DIN/EN50022 • 17.5 mm DIN-rail housing (DIN 43880) Type Selection Input current 2 - 20 AAC 5 - 50 AAC 10 - 100 AAC 2 - 20 AAC 5 - 50 AAC 10 - 100 AAC Output Specifications Reaction time Standard Standard Standard Fast Fast Fast Type no. DIA53 C724 20A DIA53 C724 50A DIA53 C724 100A DIA53 C724 20AF DIA53 C724 50AF DIA53 C724 100AF Input Specifications Current range Max. current (continuously) Max. overload current (t = 30 s) Output S.C.R. NO Output current Minimum load current Leakage current Min. off state voltage Voltage drop (Ud) 800 mA ≤ 100 μA 400 VAC < 1.5 VAC Max. holding current 5 mA Max. latching current 6 mA Critical dv/dt 100V/us Critical di/dt 30A/us Fusing current (I2 t) 0.32A2 s DIA53 C 724 20A/...AF DIA53 C 724 50A/...AF DIA53 C 724 100A/...AF 2 - 20 AAC @ 50 Hz 40 AAC 5 - 50 AAC @ 50 Hz 100 AAC 10 - 100 AAC @ 50 Hz 150 AAC 200 AAC 200 AAC 200 AAC General Specifications Reaction time DIA53 DIA53...F Repeatability Hysteresis (Differential travel) Frequency range Temperature variation Environment Degree of protection Pollution degree Operating temperature < 300 ms (input signal variation from -20% to +20% of set value) < 50 ms (input signal variation from -20% to +20% of set value) 0.5 % 7 - 13% of setpoint 45 - 400 Hz ±0.20%/°C of setpoint IP 20 3 -20 to +60°C Weight Screw terminals Tightening torque Housing Dimensions Material Product standard Approval CE Marking EMC Immunity Emissions www.dold-relay.com 80 g Max. 0.5 Nm acc. to IEC 60947 17.5 x 81 x 67.2 mm PA66 or Noryl EN 60255-6 UL, CSA L.V. Directive 2006/95/EC EMC Directive 2004/108/EC According to EN 60255-26 According to EN 61000-6-2 According to EN 60255-26 According to EN 61000-6-3 3 DIA53C Wiring Diagrams Dimensions 17.5 Set level 67.2 18.7 Hysteresis 1 Output ON LED ON 2 2 4 www.dold-relay.com 35.5 81 ø 12 45 Operation Diagram Monitoring Relays 1-Phase AC Over Current Type DIA53R1 Product Description Compact current monitoring relay with built-in current trans- former with adjustable set-point and 5A SPDT DC relay output. Industrial standard DC power supply for easy use. 12 mm hole for insulate current carrying wire makes it suit- able for most applications. For mounting on DIN-rail. 17.5 mm wide housing suitable both for back and front panel mounting. Property • • • • • • Input ranges: 2 - 20 AAC, 5 - 50 AAC or 10 - 100 AAC Knob-adjustable set-point Output: 5A SPDT relay normally de-energiZed LED indication for output ON For mounting on DIN-rail in accordance with DIN/EN50022 17.5 mm DIN-rail housing (DIN 43880) Type Selection Input current Reaction time Type no. 2 - 20 AAC 5 - 50 AAC 10 - 100 AAC 2 - 20 AAC 5 - 50 AAC 10 - 100 AAC Standard Standard Standard Fast Fast Fast DIA53 R1724 20A DIA53 R1724 50A DIA53 R1724 100A DIA53 R1724 20AF DIA53 R1724 50AF DIA53 R1724 100AF Input Specifications Output Specifications Output Rated insulation voltage Contact ratings (AgSnO2) Resistive loads AC 1 DC 12 Small inductive loads AC 15 DC 13 Mechanical life Electrical life SPDT relay, N.D. 250 VAC μ 5 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC ≥ 30 x 106 operations ≥ 105 operations ( at 5 A, 250 V, cos ϕ = 1) ≤ 7200 operations/h Operating frequency Dielectric strength ≥ 2 kVAC (rms) Dielectric voltage Rated impulse withstand volt. 4 kV (1.2/50 μs) DIA53 R1 724 20A/...AF DIA53 R1 724 50A/...AF DIA53 R1 724 100A/...AF Current range Max. current (continuously) Max. overload current (t = 30 s) 2 - 20 AAC @ 50 Hz 40 AAC 5 - 50 AAC @ 50 Hz 100 AAC 10 - 100 AAC @ 50 Hz 150 AAC 200 AAC 200 AAC 200 AAC Relay voltage 15 - 40 VDC 15 - 40 VDC 15 - 40 VDC Relay consumption ≤ 220mw ≤ 220mw ≤ 220mw General Specifications Reaction time DIA53 DIA53...F Repeatability Hysteresis (Differential travel) Frequency range Temperature variation Environment Degree of protection Pollution degree Operating temperature < 320 ms (input signal variation from -20% to +20% of set value) < 70 ms (input signal variation from -20% to +20% of set value) 0.5 % 7 - 13% of setpoint 45 - 400 Hz ±0.20%/°C of setpoint IP 20 3 -20 to +60°C Weight Screw terminals Tightening torque Housing Dimensions Material Product standard Approval CE Marking EMC Immunity Emissions www.dold-relay.com 85 g Max. 0.5 Nm acc. to IEC 60947 17.5 x 81 x 67.2 mm PA66 or Noryl EN 60255-6 UL, CSA L.V. Directive 2006/95/EC EMC Directive 2004/108/EC According to EN 60255-26 According to EN 61000-6-2 According to EN 60255-26 According to EN 61000-6-3 5 DIA53R1 Wiring Diagrams Dimensions 17.5 67.2 18.7 2 Operation Diagram Set level Hysteresis R elay voltage R elay ON LED ON 5 www.dold-relay.com 45 35.5 81 ø 12 Monitoring Relays 1-Phase AC Over Current Type DIA53R2 Product Description Compact current monitoring relay with built-in current trans- former with adjustable set-point and 5A SPDT AC relay output. Industrial standard AC power supply for easy use. 12 mm hole for insulate current carrying wire makes it suit- able for most applications. For mounting on DIN-rail. 17.5 mm wide housing suitable both for back and front panel mounting. Property • • • • • • Input ranges: 2 - 20 AAC, 5 - 50 AAC or 10 - 100 AAC Knob-adjustable set-point Output: 5A SPDT relay normally de-energiZed LED indication for output ON For mounting on DIN-rail in accordance with DIN/EN50022 17.5 mm DIN-rail housing (DIN 43880) Type Selection Input current Reaction time Type no. 2 - 20 AAC 5 - 50 AAC 10 - 100 AAC 2 - 20 AAC 5 - 50 AAC 10 - 100 AAC Standard Standard Standard Fast Fast Fast DIA53 R2724 20A DIA53 R2724 50A DIA53 R2724 100A DIA53 R2724 20AF DIA53 R2724 50AF DIA53 R2724 100AF Output Specifications Output Rated insulation voltage Contact ratings (AgSnO2) Resistive loads AC 1 DC 12 Small inductive loads AC 15 DC 13 Mechanical life Electrical life SPDT relay, N.D. 250 VAC μ 5 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC ≥ 30 x 106 operations ≥ 105 operations ( at 5 A, 250 V, cos ϕ = 1) ≤ 7200 operations/h Operating frequency Dielectric strength ≥ 2 kVAC (rms) Dielectric voltage Rated impulse withstand volt. 4 kV (1.2/50 μs) Input Specifications DIA53 R2 724 20A/...AF DIA53 R2 724 50A/...AF DIA53 R2 724 100A/...AF Current range Max. current (continuously) Max. overload current (t = 30 s) 2 - 20 AAC @ 50 Hz 40 AAC 5 - 50 AAC @ 50 Hz 100 AAC 10 - 100 AAC @ 50 Hz 150 AAC 200 AAC 200 AAC 200 AAC Relay voltage Relay consumption(at 50Hz ) 200 -240 VAC ≤ 0.75 VA 200 -240 VAC ≤ 0.75 VA 200 -240 VAC ≤ 0.75 VA General Specifications Reaction time DIA53 DIA53...F Repeatability Hysteresis (Differential travel) Frequency range Temperature variation Environment Degree of protection Pollution degree Operating temperature < 320 ms (input signal variation from -20% to +20% of set value) < 70 ms (input signal variation from -20% to +20% of set value) 0.5 % 7 - 13% of setpoint 45 - 400 Hz ±0.20%/°C of setpoint IP 20 3 -20 to +60°C Weight Screw terminals Tightening torque Housing Dimensions Material Product standard Approval CE Marking EMC Immunity Emissions 85 g Max. 0.5 Nm acc. to IEC 60947 17.5 x 81 x 67.2 mm PA66 or Noryl EN 60255-6 UL, CSA L.V. Directive 2006/95/EC EMC Directive 2004/108/EC According to EN 60255-26 According to EN 61000-6-2 According to EN 60255-26 According to EN 61000-6-3 www.dold-relay.com 7 DIA53R2 Wiring Diagrams Dimensions 17.5 67.2 18.7 2 Operation Diagram Set level Hysteresis R elay voltage R elay ON LED ON 8 www.dold-relay.com 45 35.5 81 ø 12