POWER-ONE VWS150YJ-A

VWS SERIES - 150 WATT
DESCRIPTION
FEATURES
VWS DC/DC converters are direct replacement
converters for the industry standard, full brick. Featuring a
fixed-frequency design, the VWS offers excellent transient
response and predictable EMI performance. The VWS can
be combined with VWB booster modules to provide
increased power. The VWS converters use 100% surfacemount construction, along with planar magnetics, and are
fully compatible with production board-washing processes.
•
•
•
•
150W Standard Full Brick • Planar Magnetics
Industry Standard Footprint • Superior Transient
Response
Open-Frame Packaging
100°C Baseplate Operation • 1500V Isolation
• VWB Booster Modules
Available
Efficiency vs. Load (24V Input)
95
EFFICIENCY %
90
85
VWS150YJ-A
EFF. (18v)
80
EFF. (24v)
75
TECHNICAL SPECIFICATIONS
Input
EFF. (36v)
70
10
Voltage Range
24 VDC Nominal
18 - 36 VDC
48 VDC Nominal
36 - 72 VDC
Input Reflected Ripple Current
500 mA Pk-Pk
Undervoltage Lockout - Turn ON / Turn OFF 17 VDC/15 VDC, 35 VDC/32 VDC
20
30
40
50
60
70
80
90
100
LOAD %
Efficiency vs. Load (48V Input)
90
85
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Remote Sense Headroom
Minimum Output Current
EFFICIENCY %
Output
±1%
0.2%
Vout
0.5% Vout
0.5 VDC
10 % Iout Rated
Dynamic Regulation, Loadstep
80
75
VWS150ZH-A
EFF. (36v)
70
EFF. (48v)
EFF. (72v)
65
25% Iout
Pk Deviation
60
8% Vout
Settling Time
Voltage Trim Range
Current Limit threshold Range, % of Iout Rated
10
20
30
40
500 ms
±10%
110 - 140%
50
60
70
80
90
100
LOAD %
General
Turn-On Time
Remote Shutdown
Remote Shutdown Reference
Notes
Safety: Agency approvals may vary from model to model. Please consult
factory for specific model information.
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
MTBF† (Bellcore TR-NWT-000332)
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
Safety
Weight (Approx.)
† MTBF predictions may vary slightly from model to model.
†† Industrial temp range available
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
REV. 08/01
1
10 ms
Positive Logic
Vin Negative
500 kHz
1500 VDC
1050 VDC
500 VDC
0.03 %/°C
-40°C To +100°C
-40°C To +125°C
105°C - 115°C
5 g, 10 - 55 Hz
Consult
Factory
UL, cUL, TUV
6.0 oz
VWS SERIES - 150 WATT
MODELS - (See the last page of section for options.)
MODEL
INPUT VOLTAGE
(VOLTS)
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
24
24
24
24
48
48
48
48
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
11.0
11.0
11.0
11.0
5.5
5.5
5.5
5.5
5
12
15
24
5
12
15
24
30.0
12.5
10.0
6.25
30.0
12.5
10.0
6.25
VWS150YG-A ∆
VWS150YH-A ∆
VWS150YJ-A
VWS150YK-A
VWS150ZG-A
VWS150ZH-A
VWS150ZJ-A ∆
VWS150ZK-A
NOTES:
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
50
120
150
200
50
120
150
200
81%
85%
88%
88%
79%
85%
85%
86%
∆ Advanced product release- consult factory.
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
! " #!# $%
& $%
$%
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
5.4 °C/W
3.8 °C/W
2.5 °C/W
1.7 °C/W
1.6 °C/W
Note:
Thermal impedance data is
dependent on many environmental
factors. The exact thermal
performance should be validated
for specific application.
Pin
Function
1
2
3
4
5
6
7
8
9
-Vin
Gate Out
Gate In
+Vin
-Vout
-Sense
Trim
+Sense
+Vout
2
Tolerances
Inches:
.XX ± .020
.XXX ± .010
Pin:
± .002
(Millimeters)
.X ± 0.5
.XX ± .25
± .05
(Dimensions as listed unless
otherwise specified.)
OPTIONS
!
!-. '
'
' '
' . "
'
0
2
3
4
5
7007) 28 6 !
70;7) 38 6 !
724) 90 "= ">
8
<
0"
724) 90 @ ">
0@
74;) 004 "=
">
74;) 004 @ ">
2"
7<;) 240 "=
">
7<;) 240 @ ">
3"
2@
3@
"# "$% "$ " "! !
&$ & &! ' '&%
"# "$% "$ " "! &$
& &!
/ /% /'
1# !
1#% 1# ! *
1# !
*
1 +
# : *
# : *
# : %16 "! "!% &!
16 * '!% '?% 6>
# : %16 "! "!% &!
16 * '!% '?% 6>
# : %16 "! "!% &!
16 * '!% '?% 6>
# : %16 "! "!% &!
16 * '!% '?% 6>
# : %16 "! "!% &!
16 * '!% '?% 6>
# : %16 "! "!% &!
16 * '!% '?% 6>
''! (!) ' * +
''! ("
) ' * +,,
6 !
7087)
49
1 ' 6
1 ' 6
1 ' 6
1 ' 6
1 ' 6
1 ' 6
+A
"$7;7BC-#'3@ D "$7;7BC-# !- 7<;) >
!70;5E-3 D !70;5E &$799BC-#'8 D &$799BC-# ! 7007) NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
3