VWS SERIES - 100 WATT DESCRIPTION FEATURES VWS DC/DC converters are direct replacement converters for industry-standard full bricks. Featuring a fixed-frequency design, the VWS offers excellent transient response and predictable EMI performance. The VWS can be combined with VWB booster modules to provide increased power. VWS converters use 100% surface-mount construction, along with planar magnetics, and are fully compatible with production board-washing processes. • 100W Full Brick • Industry Standard Footprint • Fixed Frequency • 85°C Case Operation • 6-Sided Shielding • Superior Transient Response • 1500V Isolation • Optional Booster Module TECHNICAL SPECIFICATIONS Input Voltage Range 24 VDC Nominal 48 VDC Nominal Input Reflected Ripple Current Undervoltage Lockout - Turn On / Turn Off 18 - 36 VDC 36 - 72 VDC 50 mA Pk-Pk 35 VDC / 32 VDC Output ±1% 0.2% Vout 0.5% Vout 0.5 VDC 10 % Iout Rated 25% Iout 8% Vout 500 µs ±10% Hiccup 110 - 140% 200% 120 - 140% Vout Nom. Self-Recovering Efficiency vs. Load (48V Input) 95 90 EFFICIENCY % Setpoint Accuracy Line Regulation Vin Min. - Vin Max., Iout Rated Load Regulation Iout Min. - Iout Max., Vin Nom. Remote Sense Headroom Minimum Output Current Dynamic Regulation, Loadstep Pk Deviation Settling Time Voltage Trim Range Current Limit Type Current Limit Threshold Range, % of Iout Rated Short Circuit Threshold Range, % of Iout Rated OVP Trip Range OVP/UVP type 85 VWS100ZH 80 EFF. (36v) 75 EFF. (48v) 70 EFF. (75v) 65 60 10 General Turn-On Time Remote Shutdown Remote Shutdown Reference Switching Frequency Isolation, Input - Output Isolation, Input - Case Isolation, Output - Case Temperature Coefficient Case Temperature Operating Range Storage Range Thermal Shutdown Range Vibration, 3 Axes, 5 Min Each MTBF† (Bellcore TR-NWT-000332) Safety Weight (approx.) 20 30 40 50 60 70 80 90 LOAD % 10 mS Positive Or Negative Logic Vin Negative 300 kHz 1500 VDC 1050 VDC 500 VDC 0.2%/°C Notes † MTBF predictions may vary slightly from model to model. Specifications typically at 25°C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with commercial wave-soldering equipment. -25 To +85°C -55 To +115°C 90 To 100°C 5 g, 10 - 55 Hz 2.1 x 106 hrs UL, cUL, TUV 6.0 oz Safety: Agency approvals may vary from model to model. Please consult factory for specific model information. Units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. REV. 07/01 1 100 VWS SERIES - 100 WATT MODELS - (See the last page of section for options.) SINGLE OUTPUT MODEL SELECTION CHART MODEL VWS100YG ∆ VWS100YH ∆ VWS100YJ VWS100YK VWS100Y28 ∆ VWS100YL ∆ VWS100ZG ∆ VWS100ZH VWS100ZJ ∆ VWS100ZK VWS100Z28 ∆ NOTES: INPUT VOLTAGE (VOLTS) INPUT VOLTAGE RANGE (VOLTS) MAXIMUM INPUT CURRENT (AMPS)* OUTPUT VOLTAGE (VOLTS) RATED OUTPUT CURRENT (AMPS) 24 24 24 24 24 24 48 48 48 48 48 18-36 18-36 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 36-72 7.0 7.0 7.0 7.0 7.0 7.0 3.5 3.5 3.5 3.5 3.5 5 12 15 24 28 48 5 12 15 24 28 20.0 8.3 6.7 4.2 3.6 2.1 20.0 8.3 6.7 4.2 3.6 RIPPLE & NOISE pk-pk (mV) TYPICAL EFFICIENCY** 50 120 150 200 200 200 50 120 150 200 200 82% 84% 85% 87% 90% 90% 84% 89% 89% 88% 90% ∆ Advanced product release- consult factory. * Maximum input current at minimum input voltage, maximum rated output power. ** At nominal Vin, rated output. MECHANICAL DRAWING ! " #!$ Thermal Impedance Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM 5.5 °C/W 4.6 °C/W 3.6 °C/W 2.4 °C/W 2.0 °C/W Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. Pin 1 2 3 4 5 6 7 8 9 Tolerances Function -Vin Gate OUT Gate IN +Vin -Vout -Sense Trim +Sense +Vout 2 Inches: .XX ± 0.020 .XXX ± 0.010 (Millimeters) .X ± 0.5 .XX ± 0.25 Pin: ± 0.002 ± 0.05 (Dimensions as listed unless otherwise specified.) OPTIONS ! !-. ' ' ' ' ' . " ' 0 2 3 4 5 7007) 28 6 ! 70;7) 38 6 ! 724) 90 "= "> 8 < 0" 724) 90 @ "> 0@ 74;) 004 "= "> 74;) 004 @ "> 2" 7<;) 240 "= "> 7<;) 240 @ "> 3" 2@ 3@ "# "$% "$ " "! ! &$ & &! ' '&% "# "$% "$ " "! &$ & &! / /% /' 1# ! 1#% 1# ! * 1# ! * 1 + # : * # : * # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> # : %16 "! "!% &! 16 * '!% '?% 6> ''! (!) ' * + ''! (" ) ' * +,, 6 ! 7087) 49 1 ' 6 1 ' 6 1 ' 6 1 ' 6 1 ' 6 1 ' 6 +A "$7;7BC-#'3@ D "$7;7BC-# !- 7<;) > !70;5E-3 D !70;5E &$799BC-#'8 D &$799BC-# ! 7007) NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. 3