MAXIM MXL1001AMH

19-0286; Rev 1; 8/94
Precision Operational Amplifier
________________________Applications
Thermocouple Amplifiers
Low-Level Signal Processing
______________Ordering Information
Strain Gauge Amplifiers
High-Accuracy Data Acquisition
__________________Pin Configuration
TOP VIEW
VOS TRIM
VOS TRIM
8
1
-IN 2
+IN
7
V+
6 VOUT
MXL1001
3
5
4
V-
____________________________Features
♦ Guaranteed Low Offset Voltage
MXL1001AM: 15µV max
MXL1001C: 60µV max
♦ Guaranteed Low Drift
MXL1001AM: 0.6µV/°C max
MXL1001C: 1.0µV/°C max
♦ Guaranteed Low Bias Current
MXL1001AM: 2nA max
MXL1001C: 4nA max
♦ Guaranteed CMRR
MXL1001AM: 114dB min
MXL1001C: 110dB min
♦ Guaranteed PSRR
MXL1001AM: 110dB min
MXL1001C: 106dB min
♦ Low Power Dissipation
MXL1001AM: 75mW max
MXL1001C: 80mW max
♦ Low Noise: 0.3µVp-p
N.C.
PART
TEMP. RANGE
MXL1001ACN8
0°C to +70°C
8 Plastic DIP
PIN-PACKAGE
MXL1001CN8
MXL1001ACS8
MXL1001CS8
MXL1001ACJ8
MXL1001CJ8
MXL1001ACH
MXL1001CH
MXL1001AMJ8
MXL1001MJ8
MXL1001AMH
MXL1001MH
0°C to +70°C
0°C to +70°C
0°C to +70°C
0°C to +70°C
0°C to +70°C
0°C to +70°C
0°C to +70°C
-55°C to +125°C
-55°C to +125°C
-55°C to +125°C
-55°C to +125°C
8 Plastic DIP
8 SO
8 SO
8 CERDIP
8 CERDIP
8 TO-99
8 TO-99
8 CERDIP
8 CERDIP
8 TO-99
8 TO-99
__________Typical Operating Circuit
TO-99
R1
R3
SENSING
JUNCTION
VOS TRIM 1
8
VOS TRIM
-IN 2
7
V+
6
VOUT
5
N.C.
+IN 3
MXL1001
V- 4
DIP/SO
REFERENCE
JUNCTION
MXL1001
R2
R4
R1 R2
=
R3 R4
HIGH-STABILITY
THERMOCOUPLER AMPLIFIER
________________________________________________________________ Maxim Integrated Products
Call toll free 1-800-998-8800 for free samples or literature.
1
MXL1001
_______________General Description
The MXL1001 offers significant specification improvement
over earlier precision operational amplifiers and is pincompatible with the industry-standard LT1001. Particular
attention has been paid to the optimization of key parameters such as input offset voltage, common-mode rejection,
and power-supply rejection. In addition, the high-performance MXL1001C commercial temperature device provides considerable cost savings when compared to
equivalent grades of competing precision amplifiers.
The input offset voltage of all units is less than 60µV,
allowing the premium military device, the MXL1001AM, to
be specified at 15µV max. Power dissipation is close to
half that of the industry-standard OP-07 precision op
amp, without sacrificing noise or speed performance. A
useful by-product of lower dissipation is decreased
warm-up drift.
MXL1001
Precision Operational Amplifier
ABSOLUTE MAXIMUM RATINGS
Total Supply Voltage (V+ to V-) ...........................................±22V
Continuous Power Dissipation .........................................500mW
TO-99(H)—derate at 7.1mW/°C above +80°C
CERDIP(J)—derate at 6.7mW/°C above +75°C
Plastic DIP(P)—derate at 5.6mW/°C above +36°C
Small Outline(S)—derate at 5mW/°C above +55°C
Differential Input Voltage .....................................................±30V
Input Voltage (Note 1)..........................................................±22V
Duration of Output Short Circuit ....................................Indefinite
Operating Temperature Ranges:
MXL1001C_/AC_.................................................0°C to +70°C
MXL1001M_/AM_...........................................-55°C to +125°C
Junction Temperature (TJ).................................-65°C to +160°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10sec) .............................+300°C
Note 1: For supply voltages less than ±22V, the absolute maximum input voltage is equal to the supply voltage.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VS = ±15V, TA = +25°C, unless otherwise noted.)
PARAMETER
Input Offset Voltage
Long-Term Input Offset
Voltage Stability
Input Offset Current
Input Bias Current
Input Noise Voltage
Input Noise Voltage Density
Input Resistance
(Differential Mode)
Input Voltage Range
SYMBOL
MXL1001AM
MXL1001AC
MIN TYP MAX
MXL1001M
MXL1001C
MIN TYP MAX
MXL1001AM
7
15
18
60
MXL1001AC
10
25
18
60
0.2
1.0
0.3
1.5
µV/
Month
nA
CONDITIONS
VOS
(Note 2)
VOS/Time
(Note 3)
UNITS
µV
IOS
0.3
2.0
0.4
3.8
IB
±0.5
±2.0
±0.7
±4.0
nA
0.1Hz to 10Hz (Note 4)
0.3
0.6
0.3
0.6
µVp-p
fO = 10Hz (Note 4)
10.3
18.0
10.5
18.0
fO = 100Hz (Note 4)
10.0
13.0
10.0
13.0
fO = 1000Hz (Note 4)
9.6
11.0
9.8
11.0
eN p-p
eN
RIN
(Note 5)
IVR
30
100
15
80
nV/√Hz
MΩ
±13
±14
±13
±14
V
Common-Mode Rejection Ratio
CMRR
VCM = ±13V
114
126
110
126
dB
Power-Supply Rejection Ratio
PSRR
VS = ±3V to ±18V
110
123
106
123
dB
RL ≥ 2kΩ, VO = ±12V
450
800
400
800
RL ≥ 1kΩ, VO = ±10V
300
500
250
500
Large-Signal Voltage Gain
AVO
Output Voltage Swing
VO
RL ≥ 2kΩ
±13.0 ±14.0
±13.0 ±14.0
RL ≥ 1kΩ
±12.0 ±13.5
±12.0 ±13.5
V/mV
V
Slew Rate
SR
RL ≥ 2kΩ (Note 4)
0.1
0.25
0.1
0.25
V/µs
Closed-Loop Bandwidth
BW
AVCL = +1V (Note 4)
0.4
0.8
0.4
0.8
MHz
Power Consumption
PD
VS = ±15V, no load
46
75
48
80
VS = ±3V, no load
4
6
4
8
mW
Note 2: MXL1001A grade VOS is measured one minute after application of power. For all other grades VOS is measured
approximately 0.5 seconds after application of power.
Note 3: Long-Term Input Offset Voltage Stability refers to the average trend line of VOS vs. Time over extended periods after the first
30 days of operation. Excluding the initial hour of operation, changes in VOS during the first 30 operating days are typically
2.5µV. Parameter is sample tested.
Note 4: Sample tested.
Note 5: Guaranteed by design.
2
_______________________________________________________________________________________
Precision Operational Amplifier
MXL1001
ELECTRICAL CHARACTERISTICS
(VS = ±15V, -55°C ≤ TA ≤ +125°C, unless otherwise noted.)
PARAMETER
Input Offset Voltage
Average Temperature Coefficient
of Input Offset Voltage
Input Offset Current
Input Bias Current
Input Voltage Range
SYMBOL
VOS
CONDITIONS
MXL1001AM
MIN
(Note 6)
TCVOS
TYP
MAX
30
0.2
MXL1001M
MIN
UNITS
TYP
MAX
60
45
160
µV
0.6
0.3
1.0
µV/°C
IOS
0.8
4.0
1.2
7.6
nA
IB
±1.0
±4.0
±1.5
±8.0
nA
IVR
±13
±14
±13
±14
V
dB
Common-Mode Rejection Ratio
CMRR
VCM = ±13V
110
122
106
120
Power-Supply Rejection Ratio
PSRR
VS = ±3V to ±18V
104
117
100
117
dB
Large-Signal Voltage Gain
AVO
RL ≥ 2kΩ, VO = ±10V
300
700
200
700
V/mV
Output Voltage Swing
VO
RL ≥ 2kΩ
Power Dissipation
PD
No load
±12.5 ±13.5
55
±12.5 ±13.5
90
60
V
100
mW
ELECTRICAL CHARACTERISTICS
(VS = ±15V, 0°C ≤ TA ≤ +70°C, unless otherwise noted.)
PARAMETER
Input Offset Voltage
Average Temperature Coefficient
of Input Offset Voltage
Input Offset Current
Input Bias Current
Input Voltage Range
SYMBOL
VOS
CONDITIONS
MXL1001AC
MIN
(Note 6)
TCVOS
TYP
MAX
20
0.2
MXL1001C
MIN
UNITS
TYP
MAX
60
30
110
µV
0.6
0.3
1.0
µV/°C
IOS
0.5
3.5
0.6
5.3
nA
IB
±0.7
±3.5
±1.0
±5.5
nA
IVR
±13
±14
±13
±14
V
dB
Common-Mode Rejection Ratio
CMRR
VCM = ±13V
110
124
106
123
Power-Supply Rejection Ratio
PSRR
VS = ±3V to ±18V
106
120
103
120
dB
Large-Signal Voltage Gain
AVO
RL ≥ 2kΩ, VO = ±10V
350
750
250
750
V/mV
Output Voltage Swing
VO
RL ≥ 2kΩ
Power Dissipation
PD
No load
±12.5 ±13.8
50
±12.5 ±13.8
85
55
V
90
mW
Note 6: MXL1001A grade offset voltage is measured one minute after application of power. For all other grades VOS is measured
0.5 seconds after power on.
_______________________________________________________________________________________
3
MXL1001
Precision Operational Amplifier
__________Applications Information
The MXL1001 series devices are pin-compatible with the
OP-07, OP-05, 725, 108A or 101A amplifiers. The
MXL1001 amplifiers can be used to upgrade older
designs using these devices, with or without removal of
external frequency compensation or nulling components.
The MXL1001 can also be used in 741, LF156 or OP-15
applications provided the nulling circuitry is removed.
The MXL1001 is specified over a wide supply voltage
range from ±3V to ±18V. Operation with lower supplies
is possible down to ±1.2V (two NiCd batteries), however, at this level the device is stable only in closed-loop
gains of +2 and above (or inverting gain of one or higher). Unless proper care is exercised, thermocouple
effects caused by temperature gradients across dissimilar metals at the input terminal connections, can exceed
the inherent offset-voltage drift of the amplifier. Air currents over the device leads should be minimized, package leads should be short, and the two input leads
should be as close together as possible and maintained
at the same temperature.
20k
1
2
INPUT
V+
8
7
MXL1001
3
V-
Figure 1. Optional Offset Nulling Circuit
___________________Chip Topography
V OS TRIM
V OS TRIM
V+
V OUT
Offset-Voltage Adjustment
The input offset voltage of the MXL1001, and its temperature drift, are minimized by zener-zap trimming at the
wafer level. If further nulling of VOS is required, this can
be performed using a 10kΩ or 20kΩ potentiometer with
no degradation of VOS drift with temperature. Trimming
to a value other than zero creates a drift of
(VOS/300)µV/°C; i.e., if VOS is adjusted to 300µV, the
change in drift will be 1µV/°C. The adjustment range
with a 10kΩ or 20kΩ potentiometer is approximately
±2.5mV. If less adjustment range is needed, the sensitivity and resolution of the offset nulling can be improved
by using a potentiometer of lower ohmic value in conjunction with fixed resistors.
OUTPUT
6
4
0.076"
(1.93mm)
V-
V OS TRIM
-IN
+IN
0.102"
(2.59mm)
SUBSTRATE IS CONNECTED TO V-
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
4 ___________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 (408) 737-7600
© 1994 Maxim Integrated Products
Printed USA
is a registered trademark of Maxim Integrated Products.