ROHM BP5013

Data Sheet
220VAC Input/12W Output
Non-Isolated AC/DC Converter with Built-In
Zero Cross Signal Output
BP5013
Dimensions (Unit : mm)
Absolute Maximum Ratings
MARKING SIDE
1
3
6
8 9 10 11 12 13 14
0.25±0.05
0.5±0.1
(Vo=12V, R2=open)
(Unless otherwise specified, Ta=25°C, Vi= −141V, Io=1000mA, V2=−5V,R1=10kΩ)
Max.
−170
−13
1000
0.2
0.2
0.35
−
−0.3
−5.3
Conditions
DC
−
−
Vi= −113 to −170V
Io=0 to 1000mA
−
−
V1 = −141V
V1=0V
Unit
V
V
mA
V
V
Vp-p
%
V
V
∗1
∗2
1
3
6
8
9
F1
AC100V
D1
10
11
12
14
1
4
C3
ZNR C1
−
D2
+
+
C2
R1
V2=−5V
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
C2: Output capacitor
C3: Noise removal capacitor
R3 : Noise removal resistor
D1: Rectifier diode
D2: Flywheel Diode
L1: Power inductor
ZNR: Varistor
R1: Pull-up resister
R2: Output voltage setting resistor
Use a fast-acting fuse of 2.0A.
Rated voltage : Beyond 250V, capacitance : 47 to 220µF
Rated ripple current : 0.22Arms or higher
Rated voltage : Please ensure a rated voltage (whose value is proportional
to the output voltage) with sufficient margin
capacitance : 330 to 1000µF, low impedance type
ESR : Less than 0.08Ω
Rated ripple current : Byond 1.0Arms
Evaluate under actual operating conditions since it affects the output ripple voltage.
Rated voltage : Beyond 250V, Capacity : 0.1 to 0.22µF
Film or ceramic capacitor
Resistance : 10 to 22Ω, Power : More than 1/4W
Peak reverse voltage : More than 400V
Mean rectifying current : More than 1.0A
Peak forward surge current : More than 20A
Full-wave rectification can be used.
Peak reverse voltage : More than 400V
Mean rectifying current : More than 3.0A, Fast recovery diode
Please note that both the switching and efficiency characteristics
of the module are affected by this diode. Recommended
products : RF2001T4S (Rohm), 31DF4 (Nihon Inter), RU30 (Sanken).
Inductance : 330µH (Vo=-12V)
Rated current : More than 1.3A
Please refer to the Output Voltage Settings table to the right.
A varistor is required to protect against lightning surges and static electricity.
10kΩ 1/10W
Refer to the Output Voltage Settings table to the right.
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
1/1
1000
Load Regulation
(Vi=-141V, R2=open, Ta=25°C)
Vo
Coil start
External Component Specifications
F1: FUSE
C1: Input capacitor
200
400
600
800
Output Current Io (mA)
Load Regulation
Io
L1
−
0
Zero-cross
signal
R2
R3
13
Conversion Efficiency
(Vi=-141V, R2=open, Ta=25°C)
Conversion Efficiency (%)
BP5013
Be sure to use
a fuse for safety
Derating Curve
14
12
10
8
6
Operation Range
4
2
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Ambient Temperature Ta (°C)
100
90
80
70
60
50
40
30
20
10
0
Application Circuit
Function
Zero-cross input 1 (ACin)
Skip
Input (Vi)
Skip
Skip
Coil 1 (Coil-1)
Skip
Coil 2 (Coil-2)
Output (Vo)
ADJ (VoADJ)
Common
Test
Zero-cross signal output (Zcout)
Zero-cross signal input (-5V) (Zc)
7.55MAX.
Conversion Efficiency
∗1 Max output current should be reduced according to the surrounding temperature.
∗2 The output ripple voltage may vary depending on the capacitance, environment, and location of peripheral components.
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
2.54�13=33.02TYP
Derating Curve
Output Power (W)
Typ.
−141
−12
−
0.03
0.13
0.22
83
−
−5.0
-14.0
Output Voltage Vo (V)
Symbol Min.
Parameter
−113
Input voltage range
Vi
−11
Output voltage
Vo
−
Output current
Io
−
Line regulation
Vr
−
Load regulation
Vl
−
Output ripple voltage
Vp
75
Power conversion efficiency
η
0
Zero-cross signal H
VzH
−4.6
Zero-cross signal L
VzL
3.25MAX
3.65MAX.
2.54±0.2
1.3±0.2
Electrical Characteristics
11.2MAX.
38.5MAX.
Unit
V
Vrms
°C
°C
°C
W
Limits
−170
120
−20 to +85
−25 to +105
105
12
23.2MAX.
Symbol
Vi
V1
Topr
Tstg
Tsmax
Po
4.0±1.0
Parameter
Input voltage
Zero-cross input voltage
Operating temperature range
Storage temperature range
Maximum surface temperature
Maximum output power
-12.0
-10.0
-8.0
Maximum
Io=1000mA
-6.0
-4.0
-2.0
0.0
0
200
400 600 800 1000 1200 1400
Output Current Io (mA)
Output Voltage Settings
Vo
Io
R2
L1
−12V
1000mA
open
330µH
−15V
800mA
75kΩ
470µH
−24V
500mA
8.2kΩ
1mH
−30V
400mA
1.8kΩ
1mH
Vo
9
47kΩ
+
−
12kΩ
36kΩ
Vref=6.9V
R2
10
VoADJ
11
COM
Output block diagram
2010.01 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010A