Data Sheet 220VAC Input/12W Output Non-Isolated AC/DC Converter with Built-In Zero Cross Signal Output BP5013 Dimensions (Unit : mm) Absolute Maximum Ratings MARKING SIDE 1 3 6 8 9 10 11 12 13 14 0.25±0.05 0.5±0.1 (Vo=12V, R2=open) (Unless otherwise specified, Ta=25°C, Vi= −141V, Io=1000mA, V2=−5V,R1=10kΩ) Max. −170 −13 1000 0.2 0.2 0.35 − −0.3 −5.3 Conditions DC − − Vi= −113 to −170V Io=0 to 1000mA − − V1 = −141V V1=0V Unit V V mA V V Vp-p % V V ∗1 ∗2 1 3 6 8 9 F1 AC100V D1 10 11 12 14 1 4 C3 ZNR C1 − D2 + + C2 R1 V2=−5V Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating. C2: Output capacitor C3: Noise removal capacitor R3 : Noise removal resistor D1: Rectifier diode D2: Flywheel Diode L1: Power inductor ZNR: Varistor R1: Pull-up resister R2: Output voltage setting resistor Use a fast-acting fuse of 2.0A. Rated voltage : Beyond 250V, capacitance : 47 to 220µF Rated ripple current : 0.22Arms or higher Rated voltage : Please ensure a rated voltage (whose value is proportional to the output voltage) with sufficient margin capacitance : 330 to 1000µF, low impedance type ESR : Less than 0.08Ω Rated ripple current : Byond 1.0Arms Evaluate under actual operating conditions since it affects the output ripple voltage. Rated voltage : Beyond 250V, Capacity : 0.1 to 0.22µF Film or ceramic capacitor Resistance : 10 to 22Ω, Power : More than 1/4W Peak reverse voltage : More than 400V Mean rectifying current : More than 1.0A Peak forward surge current : More than 20A Full-wave rectification can be used. Peak reverse voltage : More than 400V Mean rectifying current : More than 3.0A, Fast recovery diode Please note that both the switching and efficiency characteristics of the module are affected by this diode. Recommended products : RF2001T4S (Rohm), 31DF4 (Nihon Inter), RU30 (Sanken). Inductance : 330µH (Vo=-12V) Rated current : More than 1.3A Please refer to the Output Voltage Settings table to the right. A varistor is required to protect against lightning surges and static electricity. 10kΩ 1/10W Refer to the Output Voltage Settings table to the right. www.rohm.com ©2010 ROHM Co., Ltd. All rights reserved. 1/1 1000 Load Regulation (Vi=-141V, R2=open, Ta=25°C) Vo Coil start External Component Specifications F1: FUSE C1: Input capacitor 200 400 600 800 Output Current Io (mA) Load Regulation Io L1 − 0 Zero-cross signal R2 R3 13 Conversion Efficiency (Vi=-141V, R2=open, Ta=25°C) Conversion Efficiency (%) BP5013 Be sure to use a fuse for safety Derating Curve 14 12 10 8 6 Operation Range 4 2 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature Ta (°C) 100 90 80 70 60 50 40 30 20 10 0 Application Circuit Function Zero-cross input 1 (ACin) Skip Input (Vi) Skip Skip Coil 1 (Coil-1) Skip Coil 2 (Coil-2) Output (Vo) ADJ (VoADJ) Common Test Zero-cross signal output (Zcout) Zero-cross signal input (-5V) (Zc) 7.55MAX. Conversion Efficiency ∗1 Max output current should be reduced according to the surrounding temperature. ∗2 The output ripple voltage may vary depending on the capacitance, environment, and location of peripheral components. Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 2.54�13=33.02TYP Derating Curve Output Power (W) Typ. −141 −12 − 0.03 0.13 0.22 83 − −5.0 -14.0 Output Voltage Vo (V) Symbol Min. Parameter −113 Input voltage range Vi −11 Output voltage Vo − Output current Io − Line regulation Vr − Load regulation Vl − Output ripple voltage Vp 75 Power conversion efficiency η 0 Zero-cross signal H VzH −4.6 Zero-cross signal L VzL 3.25MAX 3.65MAX. 2.54±0.2 1.3±0.2 Electrical Characteristics 11.2MAX. 38.5MAX. Unit V Vrms °C °C °C W Limits −170 120 −20 to +85 −25 to +105 105 12 23.2MAX. Symbol Vi V1 Topr Tstg Tsmax Po 4.0±1.0 Parameter Input voltage Zero-cross input voltage Operating temperature range Storage temperature range Maximum surface temperature Maximum output power -12.0 -10.0 -8.0 Maximum Io=1000mA -6.0 -4.0 -2.0 0.0 0 200 400 600 800 1000 1200 1400 Output Current Io (mA) Output Voltage Settings Vo Io R2 L1 −12V 1000mA open 330µH −15V 800mA 75kΩ 470µH −24V 500mA 8.2kΩ 1mH −30V 400mA 1.8kΩ 1mH Vo 9 47kΩ + − 12kΩ 36kΩ Vref=6.9V R2 10 VoADJ 11 COM Output block diagram 2010.01 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2010 ROHM Co., Ltd. All rights reserved. R1010A