ROHM BP5034D12_10

Data Sheet
100VAC Input/12VDC (100mA) Output
Non-Isolated AC/DC Converter
BP5034D12
Absolute Maximum Ratings
Unit
Vi
Io
Vsurge
Topr
Tstg
195
100
2
−25 to +80
−25 to +105
V
mApk
kV
°C
°C
28.2MAX.
10.0MAX.
Mark Side
Limits
15.7MAX.
Symbol
1
4±1.0
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Dimensions (Unit : mm)
2
3
4 5
6 7
8
10
0.25± 0.05
0 . 5 ±0 . 1
1 . 3 ±0 . 2
P = 2 . 5 4 ±0 . 2
3.25MAX.
3.5MAX.
6.5MAX.
2.54�9=22.86
Electrical Characteristics
Derating curve
Conditions
DC(80 to 138VAC level)
Vi=141V, Io=50mA
Vi=141V
Vi=113 to 195V, Io=50mA
Vi=141V, Io=0 to 50mA
Vi=141V, Io=50mA
Vi=141V, Io=100mA
∗1 The max output is changed due to the ambient temperature. Please refer to note regarding derating curve.
∗2 Please refer to Conversion efficiency.
Application Circuit
Pin No.
1
2
3
4
5
6
7
8
9
10
BP5034D12
Please note that pin No.10
side is input.
10
Input
AC100V
50Hz/60Hz
ZNR
+
220V −
8 7 6 5 4 3 2 1
FUSE
0.5A
R1
D1
1SR35−400A 10Ω1/4W
C1
10µF/250V
Output
+12V
C2
+
0.1µF
−
Terminal definition
Output terminal Vo(12V)
N.C.
N.C.
N.C.
COMMON
COMMON
N.C.
N.C.
Skipping Pin
Input terminal Vi(141VDC)
C3
100µF/50V
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actual usage and
ensure that the load current does not exceed 0.1A.
FUSE: Fuse
Use a fuse of 0.5A
C1 : Input smoothing
capacitor
Capacitance : 3.3 to 22µF Ripple current is 0.13Arms or above.
Rated voltage : 200V or higher
C2 : Noise reduction
capacitor
Capacitance : 0.1 to 0.22µF Rated voltage : 200V or higher
Use a film or ceramic capacitor. Evaluate under actual operating conditions.
C3 : Output smoothing
capacitor
Capacitance : 100 to 470µF Rated voltage : 25V or higher, low impedance
Impedance is 0.39Ω max at high frequencies.
Ripple current is 0.1Arms or above.
Capacitance impedance affects the output ripple voltage.
In the absolute maximum ratings, the reverse surge voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the forward surge current should be 20A or higher.
R1 : Noise reduction
resistor
ZNR : Varistor
10 to 22Ω 1/4W
Determine the ideal value through actual testing.
A varistor must be used to protect against lightning surges and static
electricity.
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
∗1
100
80
60
20
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
∗2
∗2
Operation Range
40
Switching Frequency
100
90
80
70
60
50
40
30
20
10
0
Switching Frequency
(Ta=25°C, Vi=141V)
0
20
40
60
80
Output Current Io(mA)
100
Conversion Efficiency
80
70
60
50
40
30
20
10
0
Conversion Efficiency
(Ta=25°C, Vi=141V)
60% Min−Line
0
20
40
60
80
Output Current Io(mA)
100
Load Regulation
External Component Specifications
D1 : Rectifier diode
Derating Curve
120
Output Current Io(mA)
Unit
V
V
mA
V
V
Vp-p
%
Switching Frequency fsw(kHz)
Max.
195
12.8
100
0.1
0.15
0.15
−
Conversion Efficiency (%)
Typ.
141
12
−
0.02
0.05
0.05
68
1/1
Output Voltage Vo(V)
Min.
113
11
0
−
−
−
60
13.0
12.8
12.6
12.4
12.2
12.0
11.8
11.6
11.4
11.2
11.0
Load Regulation
(Ta=25°C, Vi=141V)
0
20
40
60
80
Output Current Io(mA)
100
Surface Temperature Increase
Temperature Rising ∆T(°C)
Symbol
Parameter
Input voltage range
Vi
Output voltage
Vo
Output current
Io
Line regulation
Vr
Load regulation
Vl
Output ripple voltage
Vp
Power conversion efficiency η
Surface Temperature Increase
(Ta=25°C, Vi=141V)
40
30
20
10
0
0
20
40
60
80
Output Current Io(mA)
100
2010.01 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010A