CD54ACT153, CD74ACT153 DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS SCHS339 – MARCH 2003 D D D D D D Inputs Are TTL-Voltage Compatible Speed of Bipolar F, AS, and S, With Significantly Reduced Power Consumption Balanced Propagation Delays ±24-mA Output Drive Current – Fanout to 15 F Devices SCR-Latchup-Resistant CMOS Process and Circuit Design Exceeds 2-kV ESD Protection Per MIL-STD-883, Method 3015 CD54ACT153 . . . F PACKAGE CD74ACT153 . . . E OR M PACKAGE (TOP VIEW) 1G B 1C3 1C2 1C1 1C0 1Y GND 1 16 2 15 3 14 4 13 5 12 6 11 7 10 8 9 VCC 2G A 2C3 2C2 2C1 2C0 2Y description/ordering information Each of these data selectors/multiplexers contains inverters and drivers to supply full binary decoding data selection to the AND-OR gates. Separate strobe (G) inputs are provided for each of the two 4-line sections. ORDERING INFORMATION ORDERABLE PART NUMBER PACKAGE† TA PDIP – E –55°C 55°C to 125°C SOIC – M Tube CD74ACT153E Tube CD74ACT153M Tape and reel CD74ACT153M96 TOP-SIDE MARKING CD74ACT153E ACT153M CDIP – F Tube CD54ACT153F3A CD54ACT153F3A † Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package. FUNCTION TABLE INPUTS SELECT‡ DATA C2 C3 G OUTPUT Y L B A C0 C1 X X X X X X H L L L X X X L L L L H X X X L H L H X L X X L L L H X H X X L H H L X X L X L L H L X X H X L H H H X X X L L L H H X X X H L ‡ Select inputs A and B are common to both sections. H Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright 2003, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. On products compliant to MIL-PRF-38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 CD54ACT153, CD74ACT153 DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS SCHS339 – MARCH 2003 logic diagram (positive logic) A B 1G 1C0 14 2 1 6 TG TG 1C1 5 TG 7 1C2 4 1Y TG TG 1C3 2G 2C0 3 TG 15 10 TG TG 2C1 11 TG 9 2C2 12 TG TG 2C3 2 13 TG POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2Y CD54ACT153, CD74ACT153 DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS SCHS339 – MARCH 2003 absolute maximum ratings over operating free-air temperature range† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 6 V Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA Package thermal impedance, θJA (see Note 2): E package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67°C/W M package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73°C/W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The package thermal impedance is calculated in accordance with JESD 51-7. recommended operating conditions (see Note 3) TA = 25°C –40°C to 85°C UNIT MIN MAX MIN MAX MIN MAX 4.5 5.5 4.5 5.5 4.5 5.5 VCC VIH Supply voltage VIL VI Low-level input voltage Input voltage 0 VO IOH Output voltage 0 High-level output current –24 IOL ∆t/∆v Low-level output current Input transition rise or fall rate High-level input voltage –55°C to 125°C 2 2 0.8 2 V 0.8 V VCC VCC V –24 –24 mA 24 24 24 mA 10 10 10 ns/V VCC VCC 0.8 V 0 0 VCC VCC 0 0 V NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 CD54ACT153, CD74ACT153 DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS SCHS339 – MARCH 2003 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS MIN VOH VOL VI = VIH or VIL VI = VIH or VIL II ICC VI = VCC or GND VI = VCC or GND, DICC‡ VI = VCC – 2.1 V –55°C to 125°C TA = 25°C VCC MAX MIN –40°C to 85°C MAX MIN UNIT MAX IOH = –50 µA IOH = –24 mA IOH = –50 mA† 4.5 V 4.4 4.5 V 3.94 IOH = –75 mA† IOL = 50 µA 5.5 V 4.5 V 0.1 0.1 0.1 IOL = 24 mA IOL = 50 mA† 4.5 V 0.36 0.5 0.44 IOL = 75 mA† 5.5 V 5.5 V 4.4 4.4 3.7 3.8 3.85 5.5 V IO = 0 V 3.85 1.65 V 1.65 5.5 V ±0.1 ±1 ±1 µA 5.5 V 8 160 80 µA 2.4 3 2.8 mA 4.5 V to 5.5 V Ci 10 10 10 pF † Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive capability at 125°C. ‡ Additional quiescent supply current per input pin, TTL inputs high, 1 unit load ACT INPUT LOAD TABLE INPUT UNIT LOAD A or B 1 C 1 G 0.47 Unit Load is ∆ICC limit specified in electrical characteristics table (e.g., 2.4 mA at 25°C). switching characteristics over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1) FROM (INPUT) TO (OUTPUT) tPLH tPHL A or B Y tPLH tPHL Any C Y tPLH tPHL G Y PARAMETER –55°C to 125°C –40°C to 85°C UNIT MIN MAX MIN MAX 5.5 22 5.7 20 5.5 22 5.7 20 4.5 18 4.6 16.4 4.5 18 4.6 16.4 3.2 12.6 3.2 11.5 3.2 12.6 3.2 11.5 ns ns ns operating characteristics, TA = 25°C PARAMETER Cpd 4 TYP Power dissipation capacitance 93 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 UNIT pF CD54ACT153, CD74ACT153 DUAL 4-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS SCHS339 – MARCH 2003 PARAMETER MEASUREMENT INFORMATION S1 R1 = 500 Ω From Output Under Test 2 × VCC Open GND CL = 50 pF (see Note A) R2 = 500 Ω TEST S1 tPLH/tPHL tPLZ/tPZL tPHZ/tPZH Open 2 × VCC GND tw 3V 1.5 V Input LOAD CIRCUIT 1.5 V 0V VOLTAGE WAVEFORMS PULSE DURATION CLR Input 3V Reference Input 3V 1.5 V 1.5 V 0V 0V trec Data Input 3V 1.5 V CLK th tsu 1.5 V 10% 90% 90% tr 0V VOLTAGE WAVEFORMS RECOVERY TIME 3V 1.5 V 10% 0 V tf VOLTAGE WAVEFORMS SETUP AND HOLD AND INPUT RISE AND FALL TIMES 3V Input 1.5 V 1.5 V 0V tPLH In-Phase Output 50% 10% 90% 90% tr 90% 1.5 V 1.5 V 0V tPHL tPHL Out-of-Phase Output 3V Output Control VOH 50% VCC 10% VOL tf tPLH 50% VCC 10% tf 50% 10% 90% VOH VOL tr VOLTAGE WAVEFORMS PROPAGATION DELAY AND OUTPUT TRANSITION TIMES Output Waveform 1 S1 at 2 × VCC (see Note B) tPLZ tPZL 20% VCC tPHZ tPZH Output Waveform 2 S1 at GND (see Note B) ≈VCC 20% VCC VOL 80% VCC VOH 80% VCC ≈0 V VOLTAGE WAVEFORMS OUTPUT ENABLE AND DISABLE TIMES NOTES: A. CL includes probe and test-fixture capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns. Phase relationships between waveforms are arbitrary. D. For clock inputs, fmax is measured with the input duty cycle at 50%. E. The outputs are measured one at a time with one input transition per measurement. F. tPLH and tPHL are the same as tpd. G. tPZL and tPZH are the same as ten. H. tPLZ and tPHZ are the same as tdis. I. All parameters and waveforms are not applicable to all devices. Figure 1. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5 PACKAGE OPTION ADDENDUM www.ti.com 26-Sep-2005 PACKAGING INFORMATION Orderable Device Status (1) Package Type CD54ACT153F3A ACTIVE CDIP J 16 1 TBD Call TI Level-NC-NC-NC CD74ACT153E ACTIVE PDIP N 16 25 Pb-Free (RoHS) CU NIPDAU Level-NC-NC-NC CD74ACT153EE4 ACTIVE PDIP N 16 25 Pb-Free (RoHS) CU NIPDAU Level-NC-NC-NC CD74ACT153M ACTIVE SOIC D 16 40 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM CD74ACT153M96 ACTIVE SOIC D 16 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM CD74ACT153M96E4 ACTIVE SOIC D 16 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM CD74ACT153ME4 ACTIVE SOIC D 16 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM CD74ACT153NSR ACTIVE SO NS 16 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM CD74ACT153NSRE4 ACTIVE SO NS 16 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM Package Drawing Pins Package Eco Plan (2) Qty 40 Lead/Ball Finish MSL Peak Temp (3) (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS) or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security Telephony www.ti.com/telephony Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265 Copyright 2005, Texas Instruments Incorporated