ETC CDC2510APW

CDC2510A
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS604B– APRIL 1998 – REVISED JULY 2001
D
D
D
D
D
D
D
D
D
D
PW PACKAGE
(TOP VIEW)
Spread Spectrum Clock Compatible
100-MHz Maximum Frequency
Available in Plastic 24-Pin TSSOP
Phase-Lock Loop Clock Distribution for
Synchronous DRAM Applications
Distributes One Clock Input to One Bank of
Ten Outputs
Single Output Enable Terminal Controls All
Ten Outputs
External Feedback (FBIN) Pin Is Used to
Synchronize the Outputs to the Clock Input
On-Chip Series Damping Resistors
No External RC Network Required
Operates at 3.3-V VCC
AGND
VCC
1Y0
1Y1
1Y2
GND
GND
1Y3
1Y4
VCC
G
FBOUT
1
24
2
23
3
22
4
21
5
20
6
19
7
18
8
17
9
16
10
15
11
14
12
13
CLK
AVCC
VCC
1Y9
1Y8
GND
GND
1Y7
1Y6
1Y5
VCC
FBIN
description
The CDC2510A is a high-performance, low-skew, low-jitter, phase-lock loop (PLL) clock driver. It uses a PLL
to precisely align, in both frequency and phase, the feedback (FBOUT) output to the clock (CLK) input signal.
It is specifically designed for use with synchronous DRAMs. The CDC2510A operates at 3.3-V VCC and provides
integrated series-damping resistors that make it ideal for driving point-to-point loads.
One bank of ten outputs provides ten low-skew, low-jitter copies of CLK. Output signal duty cycles are adjusted
to 50 percent, independent of the duty cycle at CLK. All outputs can be enabled or disabled via a single output
enable input. When the G input is high, the outputs switch in phase and frequency with CLK; when the G input
is low, the outputs are disabled to the logic-low state.
Unlike many products containing PLLs, the CDC2510A does not require external RC networks. The loop filter
for the PLL is included on-chip, minimizing component count, board space, and cost.
Because it is based on PLL circuitry, the CDC2510A requires a stabilization time to achieve phase lock of the
feedback signal to the reference signal. This stabilization time is required, following power up and application
of a fixed-frequency, fixed-phase signal at CLK, and following any changes to the PLL reference or feedback
signals. The PLL can be bypassed for test purposes by strapping AVCC to ground.
The CDC2510A is characterized for operation from 0°C to 70°C.
FUNCTION TABLE
INPUTS
OUTPUTS
G
CLK
1Y
(0:9)
X
L
L
L
L
H
L
H
H
H
H
H
FBOUT
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright  2001, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
CDC2510A
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS604B– APRIL 1998 – REVISED JULY 2001
functional block diagram
G
11
3
4
5
8
9
15
16
CLK
24
ÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎ
ÁÁÁÁÁÁ
ÎÎÎÎÎÎÎ
ÁÁÁÁÁÁ
ÎÎÎÎÎÎÎ
17
PLL
FBIN
AVCC
13
20
21
1Y1
1Y2
1Y3
1Y4
1Y5
1Y6
1Y7
1Y8
1Y9
23
12
AVAILABLE OPTIONS
PACKAGE
2
1Y0
TA
SMALL OUTLINE
(PW)
0°C to 70°C
CDC2510A
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
FBOUT
CDC2510A
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS604B– APRIL 1998 – REVISED JULY 2001
Terminal Functions
TERMINAL
NAME
NO.
TYPE
DESCRIPTION
CLK
24
I
Clock input. CLK provides the clock signal to be distributed by the CDC2510A clock driver. CLK is
used to provide the reference signal to the integrated PLL that generates the clock output signals. CLK
must have a fixed frequency and fixed phase for the PLL to obtain phase lock. Once the circuit is
powered up and a valid CLK signal is applied, a stabilization time is required for the PLL to phase lock
the feedback signal to its reference signal.
FBIN
13
I
Feedback input. FBIN provides the feedback signal to the internal PLL. FBIN must be hard-wired to
FBOUT to complete the PLL. The integrated PLL synchronizes CLK and FBIN so that there is
nominally zero phase error between CLK and FBIN.
G
11
I
Output bank enable. G is the output enable for outputs 1Y(0:9). When G is low, outputs 1Y(0:9) are
disabled to a logic-low state. When G is high, all outputs 1Y(0:9) are enabled and switch at the same
frequency as CLK.
FBOUT
12
O
Feedback output. FBOUT is dedicated for external feedback. It switches at the same frequency as
CLK. When externally wired to FBIN, FBOUT completes the feedback loop of the PLL. FBOUT has
and integrated 25-Ω series-damping resistor.
1Y (0:9)
3, 4, 5, 8, 9
15, 16, 17, 20,
21
O
Clock outputs. These outputs provide low-skew copies of CLK. Output bank 1Y(0:9) is enabled via
the G input. These outputs can be disabled to a logic-low state by deasserting the G control input.
Each output has an integrated 25-Ω series-damping resistor.
AVCC
23
Power
Analog power supply. AVCC provides the power reference for the analog circuitry. In addition, AVCC
can be used to bypass the PLL for test purposes. When AVCC is strapped to ground, PLL is bypassed
and CLK is buffered directly to the device outputs.
AGND
1
Ground
Analog ground. AGND provides the ground reference for the analog circuitry.
VCC
GND
2, 10, 14, 22
Power
Power supply
6, 7, 18, 19
Ground
Ground
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
CDC2510A
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS604B– APRIL 1998 – REVISED JULY 2001
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, AVCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AVCC < VCC +0.7 V
Supply voltage range, VCC, AVCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V
Input voltage range, VI (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 6.5 V
Voltage range applied to any output in the high
or low state, VO (see Notes 2 and 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through each VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. AVCC must not exceed VCC.
2. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
3. This value is limited to 4.6 V maximum.
4. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils.
For more information, refer to the Package Thermal Considerations application note in the ABT Advanced BiCMOS Technology Data
Book, literature number SCBD002.
recommended operating conditions (see Note 5)
MIN
MAX
Supply voltage, VCC, AVCC
3
3.6
High-level input voltage, VIH
2
Low-level input voltage, VIL
0
High-level output current, IOH
Low-level output current, IOL
Operating free-air temperature, TA
NOTE 5: Unused inputs must be held high or low to prevent them from floating.
4
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
0
V
V
0.8
Input voltage, VI
UNIT
V
VCC
–12
mA
V
12
mA
70
°C
CDC2510A
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS604B– APRIL 1998 – REVISED JULY 2001
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VIK
II = –18 mA
IOH = –100 µA
VOH
IOH = –12 mA
IOH = – 6 mA
VOL
II
ICC§
∆ICC
Ci
Co
AVCC, VCC
3V
MIN
MIN to MAX
3V
VCC – 0.2
2.1
3V
2.4
IOL = 100 µA
IOL = 12 mA
TYP‡
VI = VCC or GND,
One input at VCC – 0.6 V,
IO = 0, Outputs: low or high
Other inputs at VCC or GND
V
0.2
3V
0.8
3V
0.55
V
3.6 V
±5
µA
3.6 V
10
µA
500
µA
3.3 V to 3.6 V
VI = VCC or GND
VO = VCC or GND
UNIT
–1.2
V
MIN to MAX
IOL = 6 mA
VI = VCC or GND
MAX
3.3 V
4
pF
3.3 V
6
pF
‡ For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
§ For ICC of AVCC, see Figure 5.
timing requirements over recommended ranges of supply voltage and operating free-air
temperature
MIN
fclk
Clock frequency
Input clock duty cycle
Stabilization time†
MAX
UNIT
80
100
MHz
40%
60%
1
ms
† Time required for the integrated PLL circuit to obtain phase lock of its feedback signal to its reference signal. For phase lock to be obtained, a
fixed-frequency, fixed-phase reference signal must be present at CLK. Until phase lock is obtained, the specifications for propagation delay, skew,
and jitter parameters given in the switching characteristics table are not applicable. This parameter does not apply for input modulation under
SSC application.
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature, CL = 30 pF (see Note 6 and Figures 1 and 2)‡
PARAMETER
tphase error, reference
(see Note 7, Figure 3)
tphase error– jitter
(see Note 8)
tsk(o)§
Jitter(pk-pk)
(see Figure 4)
Duty cycle reference
(see Figure 4)
FROM
(INPUT)/CONDITION
TO
(OUTPUT)
80 MHz < CLKIN↑ ≤ 100 MHz
FBIN↑
CLKIN↑ = 100 MHz
FBIN↑
Any Y or FBOUT
Any Y or FBOUT
Clkin = 100 MHz
Any Y or FBOUT
F(clkin > 80 MHz)
Any Y or FBOUT
VCC, AVCC = 3.3 V
± 0.165 V
VCC, AVCC = 3.3 V
± 0.3 V
MIN
MIN
TYP
MAX
TYP
–700
–750
–350
–300
– 540
• DALLAS, TEXAS 75265
ps
ps
200
ps
–150
150
ps
45%
55%
tr
Any Y or FBOUT
1.3
1.9
0.8
2.1
tf
Any Y or FBOUT
1.7
2.5
1.2
2.7
‡ These parameters are not production tested.
§ The tsk(o) specification is only valid for equal loading of all outputs.
NOTES: 6. The specifications for parameters in this table are applicable only after any appropriate stabilization time has elapsed.
7. This is considered as static phase error.
8. Phase error does not include jitter. The total phase error is – 900 ps to –200 ps for the 5% VCC range.
POST OFFICE BOX 655303
UNIT
MAX
ns
ns
5
CDC2510A
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS604B– APRIL 1998 – REVISED JULY 2001
PARAMETER MEASUREMENT INFORMATION
3V
Input
50% VCC
0V
tpd
From Output
Under Test
30 pF
500 W
Output
2V
0.4 V
tr
LOAD CIRCUIT FOR OUTPUTS
50% VCC
VOH
2V
0.4 V
VOL
tf
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 100 MHz, ZO = 50 Ω, tr ≤ 1.2 ns, tf ≤ 1.2 ns.
C. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
CLKIN
FBIN
tphase error
FBOUT
Any Y
tsk(o)
Any Y
Any Y
tsk(o)
Figure 2. Phase Error and Skew Calculations
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CDC2510A
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS604B– APRIL 1998 – REVISED JULY 2001
TYPICAL CHARACTERISTICS
STATIC PHASE ERROR
vs
CLOCK FREQUENCY
JITTER (PEAK-TO-PEAK)
vs
CLOCK FREQUENCY
–300
–350
550
AVCC, VCC = 3.3 V
TA = 25°C
450
Jitter (Peak-to-Peak) – ps
Static Phase Error – ps
–400
–450
–500
–550
–600
–650
400
350
300
250
200
–700
–750
60
AVCC, VCC = 3.3 V
RL = 500 Ω
CL = 30 pF
TA = 25°C
All Outputs Switching
500
150
70
80
90
100
110
120
100
60
130
70
fclk – Clock Frequency – MHz
Figure 3
60
80
100
120
fclk – Clock Frequency – MHz
140
100
110
SUPPLY CURRENT
vs
CLOCK FREQUENCY
14
250
AVCC, VCC = 3.3 V
TA = 25°C
VCC = 3.6 V
TA = 25°C
CLY = CLF = 30 pF
200
I CC – Supply Current – mA
AICC – Analog Supply Current – mA
130
90
Figure 4
ANALOG SUPPLY CURRENT
vs
CLOCK FREQUENCY
12
120
80
fclk – Clock Frequency – MHz
10
8
6
4
150
100
50
2
0
30
50
70
90
110
130
0
20
40
fclk – Clock Frequency – MHz
Figure 5
Figure 6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
CDC2510A
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS604B– APRIL 1998 – REVISED JULY 2001
MECHANICAL INFORMATION
PW (R-PDSO-G**)
PLASTIC SMALL-OUTLINE PACKAGE
14 PIN SHOWN
0,30
0,19
0,65
14
0,10 M
8
0,15 NOM
4,50
4,30
6,60
6,20
Gage Plane
0,25
1
7
0°– 8°
0,75
0,50
A
Seating Plane
1,20 MAX
0,10
0,05 MIN
PINS **
8
14
16
20
24
28
A MAX
3,10
5,10
5,10
6,60
7,90
9,80
A MIN
2,90
4,90
4,90
6,40
7,70
9,60
DIM
4040064 / E 08/96
NOTES: A.
B.
C.
D.
8
All linear dimensions are in millimeters.
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion not to exceed 0,15.
Falls within JEDEC MO-153
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgment, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its products to the specifications applicable at the time of sale in accordance with
TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary
to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except
those mandated by government requirements.
Customers are responsible for their applications using TI components.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
products or services might be or are used. TI’s publication of information regarding any third party’s products
or services does not constitute TI’s approval, license, warranty or endorsement thereof.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations and notices. Representation
or reproduction of this information with alteration voids all warranties provided for an associated TI product or
service, is an unfair and deceptive business practice, and TI is not responsible nor liable for any such use.
Resale of TI’s products or services with statements different from or beyond the parameters stated by TI for
that product or service voids all express and any implied warranties for the associated TI product or service,
is an unfair and deceptive business practice, and TI is not responsible nor liable for any such use.
Also see: Standard Terms and Conditions of Sale for Semiconductor Products. www.ti.com/sc/docs/stdterms.htm
Mailing Address:
Texas Instruments
Post Office Box 655303
Dallas, Texas 75265
Copyright  2001, Texas Instruments Incorporated