TI CDC2509BPW

CDC2509B
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS613 – SEPTEMBER 1998
D
D
D
D
D
D
D
D
D
D
D
D
D
D
PW PACKAGE
(TOP VIEW)
Designed to Meet PC SDRAM Registered
DIMM Specification
Spread Spectrum Clock Compatible
Operating Frequency 25 MHz to 125 MHz
tPhase Error Minus Jitter at 66MHz to
100 MHz is ±150 ps
Jitter (pk – pk) at 66 MHz to 100 MHz is
±80 ps
Jitter (cyc – cyc) at 66 MHz to 100 MHz is
|100 ps|
Available in Plastic 24-Pin TSSOP
Phase-Lock Loop Clock Distribution for
Synchronous DRAM Applications
Distributes One Clock Input to One Bank of
Five and One Bank of Four Outputs
Separate Output Enable for Each Output
Bank
External Feedback (FBIN) Terminal Is Used
to Synchronize the Outputs to the Clock
Input
On-Chip Series Damping Resistors
No External RC Network Required
Operates at 3.3-V
AGND
VCC
1Y0
1Y1
1Y2
GND
GND
1Y3
1Y4
VCC
1G
FBOUT
1
24
2
23
3
22
4
21
5
20
6
19
7
18
8
17
9
16
10
15
11
14
12
13
CLK
AVCC
VCC
2Y0
2Y1
GND
GND
2Y2
2Y3
VCC
2G
FBIN
description
The CDC2509B is a high-performance, low-skew, low-jitter, phase-lock loop (PLL) clock driver. It uses a PLL
to precisely align, in both frequency and phase, the feedback (FBOUT) output to the clock (CLK) input signal.
It is specifically designed for use with synchronous DRAMs. The CDC2509B operates at 3.3-V VCC. It also
provides integrated series-damping resistors that make it ideal for driving point-to-point loads.
One bank of five outputs and one bank of four outputs provide nine low-skew, low-jitter copies of CLK. Output
signal duty cycles are adjusted to 50%, independent of the duty cycle at CLK. Each bank of outputs is enabled
or disabled separately via the control (1G and 2G) inputs. When the G inputs are high, the outputs switch in
phase and frequency with CLK; when the G inputs are low, the outputs are disabled to the logic-low state.
Unlike many products containing PLLs, the CDC2509B does not require external RC networks. The loop filter
for the PLL is included on-chip, minimizing component count, board space, and cost.
Because it is based on PLL circuitry, the CDC2509B requires a stabilization time to achieve phase lock of the
feedback signal to the reference signal. This stabilization time is required, following power up and application
of a fixed-frequency, fixed-phase signal at CLK, and following any changes to the PLL reference or feedback
signals. The PLL can be bypassed for test purposes by strapping AVCC to ground.
The CDC2509B is characterized for operation from 0°C to 70°C.
For application information refer to application reports High Speed Distribution Design Techniques for
CDC509/516/2509/2510/2516 (literature number SLMA003) and Using CDC2509A/2510A PLL with Spread
Spectrum Clocking (SSC) (literature number SCAA039).
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright  1998, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
CDC2509B
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS613 – SEPTEMBER 1998
FUNCTION TABLE
OUTPUTS
INPUTS
1G
2G
CLK
1Y
(0:4)
2Y
(0:3)
FBOUT
X
X
L
L
L
L
L
L
H
L
L
H
L
H
H
L
H
H
H
L
H
H
L
H
H
H
H
H
H
H
functional block diagram
1G
11
3
4
5
8
9
2G
20
24
ÎÎÎÎÎÎÎ
ÁÁÁÁÁÁ
ÎÎÎÎÎÎÎ
ÁÁÁÁÁÁ
ÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎ
PLL
FBIN
AVCC
13
23
AVAILABLE OPTIONS
PACKAGE
2
1Y1
1Y2
1Y3
1Y4
14
21
CLK
1Y0
TA
SMALL OUTLINE
(PW)
0°C to 70°C
CDC2509BPWR
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
17
16
12
2Y0
2Y1
2Y2
2Y3
FBOUT
CDC2509B
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS613 – SEPTEMBER 1998
Terminal Functions
TERMINAL
NAME
NO.
TYPE
DESCRIPTION
CLK
24
I
Clock input. CLK provides the clock signal to be distributed by the CDC2509B clock driver. CLK is used
to provide the reference signal to the integrated PLL that generates the clock output signals. CLK must
have a fixed frequency and fixed phase for the PLL to obtain phase lock. Once the circuit is powered
up and a valid CLK signal is applied, a stabilization time is required for the PLL to phase lock the
feedback signal to its reference signal.
FBIN
13
I
Feedback input. FBIN provides the feedback signal to the internal PLL. FBIN must be hard-wired to
FBOUT to complete the PLL. The integrated PLL synchronizes CLK and FBIN so that there is nominally
zero phase error between CLK and FBIN.
1G
11
I
Output bank enable. 1G is the output enable for outputs 1Y(0:4). When 1G is low, outputs 1Y(0:4) are
disabled to a logic-low state. When 1G is high, all outputs 1Y(0:4) are enabled and switch at the same
frequency as CLK.
2G
14
I
Output bank enable. 2G is the output enable for outputs 2Y(0:3). When 2G is low, outputs 2Y(0:3) are
disabled to a logic low state. When 2G is high, all outputs 2Y(0:3) are enabled and switch at the same
frequency as CLK.
FBOUT
12
O
Feedback output. FBOUT is dedicated for external feedback. It switches at the same frequency as CLK.
When externally wired to FBIN, FBOUT completes the feedback loop of the PLL. FBOUT has an
integrated 25-Ω series-damping resistor.
1Y (0:4)
3, 4, 5, 8, 9
O
Clock outputs. These outputs provide low-skew copies of CLK. Output bank 1Y(0:4) is enabled via the
1G input. These outputs can be disabled to a logic-low state by deasserting the 1G control input. Each
output has an integrated 25-Ω series-damping resistor.
2Y (0:3)
16, 17, 20, 21
O
Clock outputs. These outputs provide low-skew copies of CLK. Output bank 2Y(0:3) is enabled via the
2G input. These outputs can be disabled to a logic-low state by deasserting the 2G control input. Each
output has an integrated 25-Ω series-damping resistor.
AVCC
23
Power
Analog power supply. AVCC provides the power reference for the analog circuitry. In addition, AVCC can
be used to bypass the PLL for test purposes. When AVCC is strapped to ground, PLL is bypassed and
CLK is buffered directly to the device outputs.
AGND
1
Ground
Analog ground. AGND provides the ground reference for the analog circuitry.
VCC
GND
2, 10, 15, 22
Power
Power supply
6, 7, 18, 19
Ground
Ground
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
CDC2509B
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS613 – SEPTEMBER 1998
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, AVCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AVCC < VCC +0.7 V
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V
Input voltage range, VI (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 6.5 V
Voltage range applied to any output in the high or low state,
VO (see Notes 2 and 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through each VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Maximum power dissipation at TA = 55°C (in still air) (see Note 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7 W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. AVCC must not exceed VCC.
2. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
3. This value is limited to 4.6 V maximum.
4. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils.
For more information, refer to the Package Thermal Considerations application note in the ABT Advanced BiCMOS Technology Data
Book, literature number SCBD002.
recommended operating conditions (see Note 5)
VCC, AVCC Supply voltage
VIH
High-level input voltage
MAX
3
3.6
2
UNIT
V
V
VIL
VI
Low-level input voltage
0.8
IOH
IOL
High-level output current
VCC
–12
mA
Low-level output current
12
mA
70
°C
Input voltage
0
TA
Operating free-air temperature
NOTE 5: Unused inputs must be held high or low to prevent them from floating.
4
MIN
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
0
V
V
CDC2509B
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS613 – SEPTEMBER 1998
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VIK
II = –18 mA
IOH = –100 µA
VOH
IOH = –12 mA
IOH = – 6 mA
VOL
II
ICC§
∆ICC
Ci
Co
VCC, AVCC
3V
MIN
MIN to MAX
3V
VCC–0.2
2.1
3V
2.4
IOL = 100 µA
IOL = 12 mA
TYP‡
VI = VCC or GND,
One input at VCC – 0.6 V,
IO = 0, Outputs: low or high
Other inputs at VCC or GND
V
0.2
3V
0.8
3V
0.55
V
3.6 V
±5
µA
3.6 V
10
µA
500
µA
3.3 V to 3.6 V
VI = VCC or GND
VO = VCC or GND
UNIT
–1.2
V
MIN to MAX
IOL = 6 mA
VI = VCC or GND
MAX
3.3 V
4
pF
3.3 V
6
pF
‡ For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
§ For ICC of AVCC, and ICC vs Frequency (see Figures 7 and 8).
timing requirements over recommended ranges of supply voltage and operating free-air
temperature
fclk
Clock frequency
Input clock duty cycle
Stabilization time†
MIN
MAX
UNIT
25
125
MHz
40%
60%
1
ms
† Time required for the integrated PLL circuit to obtain phase lock of its feedback signal to its reference signal. For phase lock to be obtained, a
fixed-frequency, fixed-phase reference signal must be present at CLK. Until phase lock is obtained, the specifications for propagation delay, skew,
and jitter parameters given in the switching characteristics table are not applicable. This parameter does not apply for input modulation under
SSC application.
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature, CL = 30 pF (see Note 6 and Figures 1 and 2)‡
PARAMETER
tphase error, – jitter
(see Notes 7 and 8,
Figures 3, 4, and 5)
tsk(o)§
Jitter(pk-pk)
(see Figure 6)
Jitter(cycle-cycle)
(see Figure 6)
Duty cycle
FROM
(INPUT)/CONDITION
TO
(OUTPUT)
CLKIN↑ = 66 MHz to100 MHz
FBIN↑
Any Y or FBOUT
Any Y or FBOUT
VCC, AVCC = 3.3 V
± 0.165 V
VCC, AVCC = 3.3 V
± 0.3 V
MIN
MAX
MIN
150
–200
–150
Any Y or FBOUT
TYP
–80
TYP
200
ps
200
ps
80
Clkin = 66 MHz to 100 MHz
ps
Any Y or FBOUT
F(clkin > 60 MHz)
UNIT
MAX
Any Y or FBOUT
|100|
45%
55%
tr
Any Y or FBOUT
1.3
1.9
0.8
2.1
tf
Any Y or FBOUT
1.7
2.5
1.2
2.7
‡ These parameters are not production tested.
§ The tsk(o) specification is only valid for equal loading of all outputs.
NOTES: 6. The specifications for parameters in this table are applicable only after any appropriate stabilization time has elapsed.
7. This is considered as static phase error.
8. Phase error does not include jitter. The total phase error is – 230 ps to 230 ps for the 5% VCC range.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
ns
ns
5
CDC2509B
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS613 – SEPTEMBER 1998
PARAMETER MEASUREMENT INFORMATION
3V
Input
50% VCC
0V
tpd
From Output
Under Test
30 pF
500 W
Output
2V
0.4 V
tr
LOAD CIRCUIT FOR OUTPUTS
50% VCC
VOH
2V
0.4 V
VOL
tf
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
NOTES: A. CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 100 MHz, ZO = 50 Ω, tr ≤ 1.2 ns, tf ≤ 1.2 ns.
C. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
CLKIN
FBIN
tphase error
FBOUT
Any Y
tsk(o)
Any Y
Any Y
tsk(o)
Figure 2. Phase Error and Skew Calculations
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
CDC2509B
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS613 – SEPTEMBER 1998
TYPICAL CHARACTERISTICS
PHASE ADJUSTMENT SLOPE AND PHASE ERROR
vs
LOAD CAPACITANCE
250
50
VCC = 3.3 V
fc = 100 MHz
CLY = 30pF
TA = 25°C
Phase Error Measured
from CLK to Y
30
20
200
150
Phase Error
100
50
10
0
0
–10
–50
–20
–100
–30
Phase Error – ps
Phase Adjustment Slope – ps/pF
40
–150
Phase Adjustment Slope
–200
–40
–250
–50
0
5
10
15
20
25
30
35
40
45
50
CLF – Lumped Feedback Capacitance at FBIN – pF
Figure 3
PHASE ERROR
vs
CLOCK FREQUENCY
400
VCC = 3.3 V
CLY = CLF = 30 pF
TA = 25°C
Phase Error Measured
from CLK to FBIN
Phase Error – ps
300
200
100
0
–100
35
45
55
65
75
85
95
105
115 125
fc – Clock Frequency – MHz
Figure 4
NOTES: A. CLY = Lumped capacitive load at Y
B. CLF = Lumped feedback capacitance at FBIN
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
7
CDC2509B
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS613 – SEPTEMBER 1998
TYPICAL CHARACTERISTICS
PHASE ERROR
vs
SUPPLY VOLTAGE
JITTER
vs
CLOCK FREQUENCY
400
400
350
300
fc = 100 MHz
CLY = CLF = 30 pF
TA = 25°C
Phase Error Measured
from CLK to FBIN
VCC = 3.3 V
TA = 25°C
350
300
Jitter – ps
Phase Error – ps
250
200
150
100
250
200
150
Peak to Peak
50
100
0
50
–50
–100
2.9
3.0
3.1
3.2
3.3
3.4
3.5
3.6
0
35
3.7
Cycle to Cycle
45
55
65
VCC – Supply Voltage – V
Figure 5
200
I CC – Supply Current – mA
AI CC – Analog Supply Current – mA
AVCC = 3.6 V
Bias = 0/3 V
CLY = CLF = 30 pF
TA = 25°C
8
6
4
VCC = 3.6 V
Bias = 0/3 V
CLY = CLF = 30 pF
TA = 25°C
150
100
50
2
20
40
60
80
100
120
140
0
10
fc – Clock Frequency – MHz
20
40
60
Figure 8
NOTES: A. CLY = Lumped capacitive load at Y
B. CLF = Lumped feedback capacitance at FBIN
POST OFFICE BOX 655303
80
100
fc – Clock Frequency – MHz
Figure 7
8
105 115 125
250
10
0
10
95
SUPPLY CURRENT
vs
CLOCK FREQUENCY
16
12
85
Figure 6
ANALOG SUPPLY CURRENT
vs
CLOCK FREQUENCY
14
75
fc – Clock Frequency – MHz
• DALLAS, TEXAS 75265
120
140
CDC2509B
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
SCAS613 – SEPTEMBER 1998
MECHANICAL INFORMATION
PW (R-PDSO-G**)
PLASTIC SMALL-OUTLINE PACKAGE
14 PIN SHOWN
0,30
0,19
0,65
14
0,10 M
8
0,15 NOM
4,50
4,30
6,60
6,20
Gage Plane
0,25
1
7
0°– 8°
0,75
0,50
A
Seating Plane
1,20 MAX
0,10
0,05 MIN
PINS **
8
14
16
20
24
28
A MAX
3,10
5,10
5,10
6,60
7,90
9,80
A MIN
2,90
4,90
4,90
6,40
7,70
9,60
DIM
4040064 / E 08/96
NOTES: A.
B.
C.
D.
All linear dimensions are in millimeters.
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion not to exceed 0,15.
Falls within JEDEC MO-153
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
9
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated