A U D I B L E / V I S I B L E N O T I F I C A T I O N Chime and Chime/Strobe Models Available CH1224 Chime/Strobes Red CH24MC White CH24MCW Chimes Red CH1224 White CH1224W Accessory Mounting Plates Red S-MP BBS White S-MPW BBSW CH24MC Product Overview Chime meets UL 464 requirements for private mode Strobe meets UL 1971 requirements Field-selectable tones – Repeating 1 second chime – Repeating 1⁄4 second chime – Temporal 3 chime – Single stroke chime – Continuous / 3kHz – Continuous / 500 Hz – Temporal 3 / 3kHz – Temporal 3 / 500 Hz Flexibility. SpectrAlert products offer the flexibility to meet a broad range of requirements. SpectrAlert chimes and chime/strobes feature sixteen field-selectable electronic tones, with three different volume levels for each. Chime/strobe models are available in 15, 15/75, 30, 75, and 110 candela configurations. Installation. SpectrAlert chime and chime/strobe offer DIP switch tone selections to simplify field configuration. In addition, each device mounts to standard depth back boxes for greater installation flexibility. Small footprint or surfacemount accessory mounting plates are available for the chime. Three volume options Mount to standard back boxes Aesthetics. The SpectrAlert chime and chime/strobe incorporate the stylish, low Available in red or white S4011 7135-1209:206 7135-1209:216 System Sensor’s SpectrAlert wall-mount electronic chime and chime/strobes offers sixteen different field-selectable chime tones, each with three volume settings. Intended for private mode applications, the SpectrAlert chime meets UL 464 and the chime/strobe meets UL1971. profile design consistent with all SpectrAlert wall-mount products, and is available in red and white to meet specific installation requirements. 397-00-E 291-01-E Engineering Specifications General Electronic chime and chime/strobe shall be a System Sensor SpectrAler t model ______________. The chime shall be listed to UL 464 for fire protective signaling systems and shall per form in accordance with private mode emergency and general utility signaling. The strobe shall be listed to UL1971 and shall be approved for fire protective signaling. The strobe shall comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The chime shall have sixteen field-selectable tone options, each with three volume settings. These options shall be activated through the appropriate settings on a DIP switch located on the rear of the unit. The chime shall be capable of mounting to a standard 4″ x 4″ or 11⁄2″ back box or a single gang 2″ x 4″ 17⁄8″ back box. The chime/strobe shall be capable of mounting to a standard 4″ x 4″ or 11⁄2″ back box. The chime shall operate at 12 or 24 volts and the chime/strobe shall operate at 24 volts. Both chime and chime/strobe shall be powered from a non-coded power supply and shall be capable of operating from either a regulated DC or full wave rectified, unfiltered power supply. Chime and chime/strobe shall have an operating temperature range of 32°F to 120°F. Specifications Input Terminals 12 to 18 AWG Weight Chime: 0.5 lb. (0.2 kg) Chime/Strobe: 1.5 lbs. (0.6 kg) Operating Voltage Range* Chime: 8–33V Chime/Strobe: 16-33V Dimensions Chime with mounting plate: 5″ x 55/8″ x 21/4″ Chime/Strobe: 6 15/16″ x 5″ x 27/16″ Mounting Chime: Single gang, 4″ x 4″ back box Chime/Strobe: 4″ x 4″ back box Sound Output (UL Reverberant)** 12VDC: 54 dBA 24VDC: 60 dBA *Factor y default settings (1.0K repeating 1 second chime @ high volume) shown. Refer to installation manual for sound output levels at each tone selection. Voltages Chime: 12 or 24 VDC and FWR unfiltered* Chime/Strobe: 24 VDC and FWR unfiltered* *Must be powered with a non-coded power supply Operating Temperature 32°F to 120°F (0°C to 49°C) Electronic Chime Current Draw* 8-33VDC: 10–61mA *Average current draw varies with tones selected. Current ratings per System Sensor testing at 12VDC and 24VDC. Add current values when connecting in parallel. 8 Volts Tone 12 Volts 24 Volts 33 Volts Low Med. High Low Med. High Low Med. High Low Med. High 1.2K Repeating 1-Second Chime 51 52 55 53 54 56 57 61 52 59 61 64 1.0K Repeating 1-Second Chime 48 50 54 51 52 54 54 57 60 57 60 62 0.8K Repeating 1-Second Chime 47 47 53 49 51 52 53 55 58 55 58 60 1.2K Repeating 1/4-Second Chime 53 54 58 55 57 59 59 61 64 61 63 66 1.0K Repeating 1/4-Second Chime 49 50 54 51 53 54 55 57 60 57 59 62 0.8K Repeating 1/4-Second Chime 48 50 53 50 52 53 54 56 59 56 58 61 1.2K Temporal 3 Chime 51 52 56 52 54 55 55 57 61 58 60 63 1.0K Temporal 3 Chime 48 49 54 49 51 51 53 55 58 55 57 60 0.8K Temporal 3 Chime 46 47 51 48 50 51 52 54 57 54 56 59 1.2K Single Stroke Chime 52 53 58 52 54 56 56 58 62 58 60 64 1.0K Single Stroke Chime 47 48 53 50 51 59 53 55 58 56 58 62 0.8K Single Stroke Chime 47 48 53 49 50 52 54 56 60 56 59 61 3.0K Continuous Electromechanical 56 57 61 59 60 67 65 68 70 68 70 74 3.0K Temporal Electromechanical 51 52 56 53 54 61 56 59 62 58 60 64 0.5K Continuous Electromechanical 48 49 53 51 52 56 54 57 60 56 55 61 0.5K Temporal Electromechanical 45 47 51 47 49 53 51 52 58 52 54 60 Strobe Current Draw Candela Model No. Setting CH24MC 15 Chime/Strobe 15/75 30 75 110 Ordering Information FWR Operating Current–Strobe (mA RMS) 64 74 93 158 208 DC Operating Current–Strobe (mA RMS) 59 69 90 160 209 Description Red White Candela Voltage Chime/Strobe CH24MC CH24MCW 15, 15/75, 30, 75, 110 24 Sur face Mount Backbox Skir t BBS-CHSR BBS-CHSW N/A N/A Chime CH1224 CH1224W N/A 12/24 Small Footprint Mounting Plate S-MP S-MPW N/A N/A Sur face Mount Back Box Skir t BBS BBSW N/A N/A Universal Mounting Plate (Replacement) D-MP D-MPW N/A N/A System Sensor Sales and Service System Sensor Headquarters 3825 Ohio Avenue St. Charles, IL 60174 Ph: 800/SENSOR2 Fx: 630/377-6495 www.systemsensor.com System Sensor Canada Ph: 905.812.0767 Fx: 905.812.0771 System Sensor in China Ph: 86.29.8832.0119 Fx: 86.29.8832.5110 System Sensor – Far East Ph: 85.22.191.9003 Fx: 85.22.736.6580 System Sensor – India Ph: 91.124.237.1770 x.2700 Fx: 91.124.237.3118 System Sensor Europe Ph: 44.1403.891920 Fx: 44.1403.891921 System Sensor in Singapore Ph: 65.6273.2230 Fx: 65.6273.2610 System Sensor – Australia Ph: 613.54.281.142 Fx: 613.54.281.172 System Sensor – Russia Ph: 70.95.937.7982 Fx: 70.95.937.7983 © 2004 System Sensor. The company reserves the right to change product specifications without notice. A05-0282-005•06/04•#1301