SYSTEMSENSOR CH1224W

A U D I B L E / V I S I B L E
N O T I F I C A T I O N
Chime and
Chime/Strobe
Models Available
CH1224
Chime/Strobes
Red
CH24MC
White
CH24MCW
Chimes
Red
CH1224
White
CH1224W
Accessory Mounting Plates
Red
S-MP
BBS
White
S-MPW
BBSW
CH24MC
Product Overview
Chime meets UL 464 requirements for
private mode
Strobe meets UL 1971 requirements
Field-selectable tones
– Repeating 1 second chime
– Repeating 1⁄4 second chime
– Temporal 3 chime
– Single stroke chime
– Continuous / 3kHz
– Continuous / 500 Hz
– Temporal 3 / 3kHz
– Temporal 3 / 500 Hz
Flexibility. SpectrAlert products offer the flexibility to meet a broad range of
requirements. SpectrAlert chimes and chime/strobes feature sixteen field-selectable electronic tones, with three different volume levels for each. Chime/strobe
models are available in 15, 15/75, 30, 75, and 110 candela configurations.
Installation. SpectrAlert chime and chime/strobe offer DIP switch tone selections
to simplify field configuration. In addition, each device mounts to standard
depth back boxes for greater installation flexibility. Small footprint or surfacemount accessory mounting plates are available for the chime.
Three volume options
Mount to standard back boxes
Aesthetics. The SpectrAlert chime and chime/strobe incorporate the stylish, low
Available in red or white
S4011
7135-1209:206
7135-1209:216
System Sensor’s SpectrAlert wall-mount electronic chime and chime/strobes offers
sixteen different field-selectable chime tones, each with three volume settings.
Intended for private mode applications, the SpectrAlert chime meets UL 464 and the
chime/strobe meets UL1971.
profile design consistent with all SpectrAlert wall-mount products, and is available in red and white to meet specific installation requirements.
397-00-E
291-01-E
Engineering Specifications
General
Electronic chime and chime/strobe shall be a System Sensor SpectrAler t model ______________. The chime shall be listed to UL 464 for fire
protective signaling systems and shall per form in accordance with private mode emergency and general utility signaling. The strobe shall
be listed to UL1971 and shall be approved for fire protective signaling. The strobe shall comply with the Americans with Disabilities Act
requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s operating voltage range. The strobe light shall consist of a
xenon flash tube and associated lens/reflector system. The chime shall have sixteen field-selectable tone options, each with three volume
settings. These options shall be activated through the appropriate settings on a DIP switch located on the rear of the unit. The chime shall
be capable of mounting to a standard 4″ x 4″ or 11⁄2″ back box or a single gang 2″ x 4″ 17⁄8″ back box. The chime/strobe shall be capable of
mounting to a standard 4″ x 4″ or 11⁄2″ back box. The chime shall operate at 12 or 24 volts and the chime/strobe shall operate at 24 volts.
Both chime and chime/strobe shall be powered from a non-coded power supply and shall be capable of operating from either a regulated DC
or full wave rectified, unfiltered power supply. Chime and chime/strobe shall have an operating temperature range of 32°F to 120°F.
Specifications
Input Terminals
12 to 18 AWG
Weight
Chime:
0.5 lb. (0.2 kg)
Chime/Strobe: 1.5 lbs. (0.6 kg)
Operating Voltage Range*
Chime:
8–33V
Chime/Strobe: 16-33V
Dimensions
Chime with mounting plate:
5″ x 55/8″ x 21/4″
Chime/Strobe: 6 15/16″ x 5″ x 27/16″
Mounting
Chime:
Single gang, 4″ x 4″ back box
Chime/Strobe: 4″ x 4″ back box
Sound Output (UL Reverberant)**
12VDC:
54 dBA
24VDC:
60 dBA
*Factor y default settings (1.0K repeating 1
second chime @ high volume) shown. Refer to
installation manual for sound output levels at each
tone selection.
Voltages
Chime:
12 or 24 VDC and FWR unfiltered*
Chime/Strobe: 24 VDC and FWR unfiltered*
*Must be powered with a non-coded power supply
Operating Temperature
32°F to 120°F (0°C to 49°C)
Electronic Chime Current Draw*
8-33VDC: 10–61mA
*Average current draw varies with tones selected. Current ratings per System Sensor testing at 12VDC and 24VDC. Add current values when connecting in parallel.
8 Volts
Tone
12 Volts
24 Volts
33 Volts
Low
Med.
High
Low
Med.
High
Low
Med.
High
Low
Med.
High
1.2K Repeating 1-Second Chime
51
52
55
53
54
56
57
61
52
59
61
64
1.0K Repeating 1-Second Chime
48
50
54
51
52
54
54
57
60
57
60
62
0.8K Repeating 1-Second Chime
47
47
53
49
51
52
53
55
58
55
58
60
1.2K Repeating 1/4-Second Chime
53
54
58
55
57
59
59
61
64
61
63
66
1.0K Repeating 1/4-Second Chime
49
50
54
51
53
54
55
57
60
57
59
62
0.8K Repeating 1/4-Second Chime
48
50
53
50
52
53
54
56
59
56
58
61
1.2K Temporal 3 Chime
51
52
56
52
54
55
55
57
61
58
60
63
1.0K Temporal 3 Chime
48
49
54
49
51
51
53
55
58
55
57
60
0.8K Temporal 3 Chime
46
47
51
48
50
51
52
54
57
54
56
59
1.2K Single Stroke Chime
52
53
58
52
54
56
56
58
62
58
60
64
1.0K Single Stroke Chime
47
48
53
50
51
59
53
55
58
56
58
62
0.8K Single Stroke Chime
47
48
53
49
50
52
54
56
60
56
59
61
3.0K Continuous Electromechanical
56
57
61
59
60
67
65
68
70
68
70
74
3.0K Temporal Electromechanical
51
52
56
53
54
61
56
59
62
58
60
64
0.5K Continuous Electromechanical
48
49
53
51
52
56
54
57
60
56
55
61
0.5K Temporal Electromechanical
45
47
51
47
49
53
51
52
58
52
54
60
Strobe Current Draw
Candela
Model No.
Setting
CH24MC
15
Chime/Strobe 15/75
30
75
110
Ordering Information
FWR Operating
Current–Strobe
(mA RMS)
64
74
93
158
208
DC Operating
Current–Strobe
(mA RMS)
59
69
90
160
209
Description
Red
White
Candela
Voltage
Chime/Strobe
CH24MC
CH24MCW
15, 15/75,
30, 75, 110
24
Sur face Mount Backbox Skir t
BBS-CHSR
BBS-CHSW
N/A
N/A
Chime
CH1224
CH1224W
N/A
12/24
Small Footprint Mounting Plate
S-MP
S-MPW
N/A
N/A
Sur face Mount Back Box Skir t
BBS
BBSW
N/A
N/A
Universal Mounting Plate (Replacement)
D-MP
D-MPW
N/A
N/A
System Sensor Sales and Service
System Sensor Headquarters
3825 Ohio Avenue
St. Charles, IL 60174
Ph: 800/SENSOR2
Fx: 630/377-6495
www.systemsensor.com
System Sensor Canada
Ph: 905.812.0767
Fx: 905.812.0771
System Sensor in China
Ph: 86.29.8832.0119
Fx: 86.29.8832.5110
System Sensor – Far East
Ph: 85.22.191.9003
Fx: 85.22.736.6580
System Sensor – India
Ph: 91.124.237.1770 x.2700
Fx: 91.124.237.3118
System Sensor Europe
Ph: 44.1403.891920
Fx: 44.1403.891921
System Sensor in Singapore
Ph: 65.6273.2230
Fx: 65.6273.2610
System Sensor – Australia
Ph: 613.54.281.142
Fx: 613.54.281.172
System Sensor – Russia
Ph: 70.95.937.7982
Fx: 70.95.937.7983
© 2004 System Sensor. The company reserves the right to change product specifications without notice.
A05-0282-005•06/04•#1301