XPPOWER CPL100PD12

AC-DC Open Frame
100-225 Watts
THE XPERTS IN POWER
CPL Series
•
Isolated Outputs
•
High Peak Current Ratings
•
Compact PCB Construction
•
Optional Remote On/Off
•
Adjustable Output Voltage
•
EN55022 Level B
•
Cover, Connector & Loom Kits Available
Specification
Input
Options
Input Voltage
Input Frequency
Inrush Current
•
•
•
Power Factor
•
Earth Leakage
Current
•
•
•
See Tables
±10% V1 only
•
•
•
•
•
•
•
No minimum load required
V1 250 ms, V2 500ms
V1 40 ms, V2 20 ms at 120 VAC
0.4% max over specified input range
0.8% max for a 100% load change
150 mV pk-pk max (0 °C to +50 °C)
>105% of rated current on V1 & >101%
of peak current on V2 auto recovery
>115% of nominal value for V1 &
115-140% of nominal value for V2
•
General
Efficiency
Isolation
Designated by the following suffixes to
the model number:
Reduce leakage current <0.1 mA ‘-G’
Remote ON/OFF ‘-R’
Cover fitted ‘-C’
Screw terminals ‘-T’
Add 4 outputs by the addition of a
DC-DC converter to the board ‘-Z’
Contact Sales Office
Environmental
Output
Output Voltage
Output Voltage
Adjustment
Minimum Load
Start Up Time
Hold Up Time
Line Regulation
Load Regulation
Ripple & Noise
Overcurrent
Protection
Overvoltage
Protection
•
85-264 VAC (120-370 VDC)
47-63 Hz
15/30 A at 120/230 VAC in,
100% load & 25 °C
0.99 typical at 100 VAC, 0.93 typical at
200 VAC & 100% load to IEC61000-3-2
0.75 mA max at 230 VAC 60 Hz
•
•
Switching Frequency •
74-83% depending on specific model
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
V1 to V2 100 VAC 1 min,
cut off current 100 mA,
100 VDC 10 MΩ min
80-500 kHz
Operating
Temperature
Storage
Temperature
Humidity
Shock
Vibration
•
-10 °C to +70 °C (See Derating Curve)
•
-20 °C to +75 °C
•
•
20-90% RH, non condensing
196.1 m/s2 (20 G), 11 ms once each
X, Y & Z axis
2 G 10-55 Hz, 3 axis
•
EMC & Safety
Emissions
•
ESD Susceptibility
•
Radiated
Susceptibility
EFT/Burst
Surge
•
•
•
Safety Approvals
•
EN55022 Level B conducted
EN55022 Level B radiated
EN61000-4-2 Level 2 contact
Level 3 air
EN61000-4-3 Level 3
EN61000-4-4 Level 3
EN61000-4-5 Level 3 line to line
Level 4 line to ground
UL1950, C-UL, EN60950, VDE0160
•
•
www.xpplc.com
[email protected]
OUTPUT VOLTAGE & CURRENT RATINGS - 100 WATT MODEL
Output
Voltage
+5 V1
+24 V2
+5 V1
+12 V2
Current Rating
Maximum
Peak(1)
5.0 A
4.0 A
7A
5.0 A
5.0 A
10 A
Regulation
Line
Load
20 mV
40 mV
96 mV
150 mV
20 mV
40 mV
48 mV
100 mV
Ripple &
Noise pk-pk(2)
120 mV
150 mV
120 mV
150 mV
CPL
Efficiency(3)
Typical
Model
Number
80%
CPL100PD24
76%
CPL100PD12
Notes
1. Peak rating for 10 sec with a duty cycle of 35% max.
2. Measured with 22µF cap within 150 mm of output terminal at 20 MHz bandwidth.
3. Measured at 200 VAC input & 100% load.
•
Mechanical Details - 100 Watt Models
I/O Connector
Mating Connector
CN1
B3P5-VH
VHR-5N
CN2
B8P-VH
VHR-8N
CN3
B2B-XH-A
(Option)
CN4
B3B-XH-A
(Option)
XHP-2
XHP-3
Terminal
Chain: SVH-21T-P1.1
Loose: 8VH-21T-P1.1
Chain: SVH-21T-P1.1
Loose: 8VH-21T-P1.1
Chain: SXH-001-P0.6
Loose: BXH-001T-P0.6
Chain: SXH-001-P0.6
Loose: BXH-001T-P0.6
Pin No.
1
2
3
4
5
CN1
Input
AC(L)
AC(N)
FG
CN3 (Optional)
Pin No. Remote On/Off
1
RC(+)
2
RC(-)
Pin No.
1, 2
3, 4
5, 6
7, 8
CN2
Output
G2
V2
G1
V1
CN4 (Optional)
Pin No.
‘-Z’
1
+
2
COM
3
-
NOTES:
• Weight 420g or less (without chassis & cover).
• Tolerance ±1.
• Dimensions in mm.
• PCB Material : CEM3.
• Optional chassis & cover, order part no. CPL100 COVER or add suffix ‘-C’ to the model number to receive the unit with the cover fitted.
• Mounting torque 1.5N m (16 kgf cm) max.
• Keep drawing current per pin below 5 A (7 A @ pk load) for CN2.
• Optional connector kit available, order part no. CPL100/150 CON.
• Optional loom kit available, order part no. CPL100/150 LOOM.
Derating Curves - 100 Watt Models
OPEN FRAME
www.xpplc.com
COVER FITTED (>90 VAC INPUT)
[email protected]
OUTPUT VOLTAGE & CURRENT RATINGS - 150 WATT MODEL
Output
Voltage
+5 V 1
+24 V 2
+5 V 1
+12 V 2
Current Rating
Maximum
Peak(1)
5.0 A
6.0 A
10 A
5.0 A
7.5 A
14 A
Regulation
Line
Load
20 mV
40 mV
96 mV
150 mV
20 mV
40 mV
48 mV
100 mV
Ripple &
Noise pk-pk(2)
120 mV
150 mV
120 mV
150 mV
CPL
Efficiency(3)
Typical
Model
Number
82%
CPL150PD24
79%
CPL150PD12
Notes
•
1. Peak rating for 10 sec with a duty cycle of 35% max.
2. Measured with 22 µF cap within 150 mm of output terminal at 20 MHz bandwidth.
3. Measured at 200 V AC input & 100% load.
Mechanical Details - 150 Watt Models
I/O Connector
Mating Connector
CN1
B3P5-VH
VHR-5N
CN2
B8P-VH
VHR-8N
CN3
B2B-XH-A
(Option)
CN4
B3B-XH-A
(Option)
XHP-2
XHP-3
Terminal
Chain: SVH-21T-P1.1
Loose: 8VH-21T-P1.1
Chain: SVH-21T-P1.1
Loose: 8VH-21T-P1.1
Chain: SXH-001-P0.6
Loose: BXH-001T-P0.6
Chain: SXH-001-P0.6
Loose: BXH-001T-P0.6
CN1
Pin No.
1
2
3
4
5
Input
AC(L)
AC(N)
FG
CN3 (Optional)
Pin No. Remote On/Off
1
RC(+)
2
RC(-)
Pin No.
1, 2
3, 4
5, 6
7, 8
CN2
Output
G2
V2
G1
V1
CN4 (Optional)
Pin No.
‘-Z’
1
+
2
COM
3
-
NOTES:
• Weight 530g or less (without chassis & cover).
• Tolerance ±1.
• Dimensions in mm.
• PCB Material : CEM3.
• Optional chassis & cover, order part no. CPL150 COVER or add suffix ‘-C’ to the model number to receive the unit with the cover fitted.
• Mounting torque 1.5N m (16 kgf cm) max.
• Ensure current per pin is below 5 A (7 A @ pk load) for CN2.
• Optional connector kit available, order part no. CPL100/150 CON.
• Optional loom kit available, order part no. CPL100/150 LOOM.
Derating Curves - 150 Watt Models
OPEN FRAME
www.xpplc.com
COVER FITTED (>90 VAC INPUT)
[email protected]
OUTPUT VOLTAGE & CURRENT RATINGS - 225 WATT MODEL
Output
Voltage
+5 V1
+24 V2
+5 V1
+12 V2
Current Rating
Maximum
Peak(1)
5.0 A
9.0 A
14 A
5.0 A
10.0 A
20 A
Regulation
Line
Load
20 mV
40 mV
96 mV
150 mV
20 mV
40 mV
48 mV
100 mV
Ripple &
Noise pk-pk(2)
120 mV
150 mV
120 mV
150 mV
CPL
Efficiency(3)
Typical
Model
Number
83%
CPL225PD24
79%
CPL225PD12
Notes
•
1. Peak rating for 10 sec with a duty cycle of 35% max.
2. Measured with 22 µF cap within 150 mm of output terminal at 20 MHz bandwidth.
3. Measured at 200 V AC input & 100% load.
Mechanical Details - 225 Watt Models
I/O Connector
Mating Connector
CN1
B3P5-VH
VHR-5N
CN2
B8P-VH
VHR-8N
CN3
B2B-XH-A
(Option)
CN4
B3B-XH-A
(Option)
XHP-2
XHP-3
Terminal
Chain: SVH-21T-P1.1
Loose: 8VH-21T-P1.1
Chain: SVH-21T-P1.1
Loose: 8VH-21T-P1.1
Chain: SXH-001-P0.6
Loose: BXH-001T-P0.6
Chain: SXH-001-P0.6
Loose: BXH-001T-P0.6
Pin No.
1
2
3
4
5
CN1
Input
AC(L)
AC(N)
FG
CN3 (Optional)
Pin No.
1, 2, 3
4, 5, 6
7, 8
9, 10
CN2
Output
G2
V2
G1
V1
CN4 (Optional)
Pin No.
‘-Z’
Pin No. Remote On/Off
NOTES:
1
+
1
RC(+)
• Weight 700g or less (without chassis & cover).
2
COM
• Tolerance ±1.
2
RC(-)
• Dimensions in mm.
3
• PCB Material : CEM3.
• Optional chassis & cover, order part no. CPL225 COVER or add suffix ‘-C’ to the model number to receive the unit with the cover fitted.
• Mounting torque 1.5N m (16 kgf cm) max.
• Keep drawing current per pin below 5 A (7 A @ pk load) for CN2.
• Optional connector kit available, order part no. CPL225 CON.
• Optional loom kit available, order part no. CPL225 LOOM.
Derating Curves - 225 Watt Models
OPEN FRAME
www.xpplc.com
COVER FITTED (>90 VAC INPUT)
[email protected]
Rev 3.0