DC-AC INVERTER UNIT CXA-0359(R) (8 W DUAL OUTPUTS WITH DIMMING FUNCTION) (PRELIMINARY INFORMATION) DESCRIPTION : This low profile DC to AC Inverter is developed for Dual lamps. NL10276BC24-13 (NEC) NL8060BC31-27 (NEC) NL8060BC31-28D (NEC) APPLICABLE LCD: 6.4 to 15 inches Dual lamp type Lamp Voltage 600 Vrms Lamp Current 5.0 mArms Lamp Start Up Voltage 1.800 Vrms (Vin : 12 Vdc) FEATURES : Dimming function Remote ON/OFF Open Lamp Detection RoHS compliant (R) Boost mode TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH -10°C ~ +70°C -30°C ~ +85°C 95 %RH max 120 x 25 x 8.5 mm 120±0.3 (13) 82±0.1 (25) 1 CN1 15±0.1 1 CXA-0359 3303 MADE IN JAPAN IC2 (5) 1 25±0.3 1 9,10 CN2 (5) (10) (10) SILICONE (1.0) 8.5 max. 65mm (a:High Voltage generation area) Note: Please use plastic screw in case of a non-insulating mounting base! Components No. 1 2 3 Part Description PCB Connector CN1 Connector CN2 Qty. 1 1 1 Material UL94V-0 (FR-4 or CEM-3) 53261-0990 SM03(7-D1)B-BHS-1-TB Unit : mm Weight :23 (g) typ. Note t=1m m Molex or equal JST or equal Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (1) Version 1.2.1, 15th May 2007 DC-AC INVERTER UNIT CXA-0359(R) (8 W DUAL OUTPUTS WITH DIMMING FUNCTION) Input side CN1: Pin No. Symbols Ratings Vin 11.4 ~ 12.6 Vdc CN 1-1+2 GND CN 1-3+4 Vrm t 0 ~ 0.4 = OFF/ 2.5 ~ Vin = ON CN 1-5 Vbr / Rbr1 CN 1-6 0 ~ 2.5 Vdc / 0 + 10 k Ω Rbr2 CN 1-7 0 ~ 10 kΩ Vs t 0 / 5 Vdc CN 1-8 (PRELIMINARY INFORMATION) Output side CN2: Pin No. Symbols Vhigh CN 2-1 Vhigh CN 2-2 N.C. CN 2-3 Vlow CN 2-4 Ratings 600 Vrm s (5.0 m Arm s ) 600 Vrm s (5.0 m Arm s ) (GND) (0 t o 0.4V : Low-mode CN 1-9 H/L 0V /5V 2 .5 t o V in : High-mode Open : Low-mode) ELECTRICAL CHARACTERISTICS : Low -mode Parameters Symbols Output Current Output Current Input Current Input Current Frequency Frequency (Duty) Open Circuit Voltage Iout Iout Iin1 Iin2 F1 F2 Vopen Alarm Signal Vs t Vin (V) 12±0.6 12±0.6 12±0.6 12±0.6 12±0.6 12±0.6 11.4 12±0.6 12±0.6 12±0.6 Conditions Vrmt Vbr (V) (V) 5±0.25 2.5 5±0.25 0 5±0.25 2.5 5±0.25 2.5 5±0.25 2.5 5±0.25 0 5±0.25 2.5 5±0.25 2.5 5±0.25 2.5 5±0.25 2.5 Specification Tu (°C) -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 Min. Typ. Max. ~ +70 4.5 ~ +70 1.5 ~ +70 ~ +70 ~ +70 58 ~ +70 310 ~ +70 1600 ~ +70 4.5 ~ +70 4.5 ~ +70 - 5.0 2.2 0.6 63 340 5.0 5.0 0 5.5 2.9 0.8 1 68 370 1800 5.5 5.5 0.5 Unit Note m Arm s m Arm s Adc m Adc kHz Hz Vrm s Vdc Vdc Vdc M ax M in Remo te of f RL1 Op en RL2 Open Normal High-mode Parameters Symbols Output Current Output Current Input Current Input Current Frequency Frequency (Duty) Open Circuit Voltage Iout Iout Iin1 Iin2 F1 F2 Vopen Alarm Signal Vs t Note 1 : Note 2 : Vin (V) 12±0.6 12±0.6 12±0.6 12±0.6 12±0.6 12±0.6 11.4 12±0.6 12±0.6 12±0.6 Conditions Vrmt Vbr (V) (V) 5±0.25 2.5 5±0.25 0 5±0.25 2.5 5±0.25 2.5 5±0.25 2.5 5±0.25 0 5±0.25 2.5 5±0.25 2.5 5±0.25 2.5 5±0.25 2.5 Specification Tu (°C) -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 Min. Typ. Max. ~ +70 6.5 ~ +70 2.6 ~ +70 ~ +70 ~ +70 58 ~ +70 310 ~ +70 1800 ~ +70 4.5 ~ +70 4.5 ~ +70 - 7.0 3.5 0.8 63 340 5.0 5.0 0 7.5 4.0 1.0 1 68 370 2000 5.5 5.5 0.5 Unit Note m Arm s m Arm s Adc m Adc kHz Hz Vrm s Vdc Vdc Vdc M ax M in Remo te of f RL1 Op en RL2 Open Normal Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. Two stages of dimming range of a Hi mode and a Low mode is selectable. Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (2) Version 1.2.1, 15th May 2007 DC-AC INVERTER UNIT CXA-0359(R) (8 W DUAL OUTPUTS WITH DIMMING FUNCTION) (PRELIMINARY INFORMATION) TEST CIRCUIT : SW1 Operation of unit a b Open Operation Non operation Operation SW 3 a b Unit operation High-m ode (Lam p current 7m Arm s /Lam p) Low-m ode (Lamp current 5mA rms/ Lamp) Open Low-m ode (Lamp current 5mA rms/ Lamp) SW2 a Unit operation Voltage dim m ing Vbr= 0 ~ 2.5V (V b r=0V : M ax B rightness) b Variable res is tance dim m ing Rbr= 0 ~ 10kΩ (Rbr=0Ω : M ax B right ness) Load condition Alarm output Shut-down function*2 (CN1-8)*1 Normal condition 0.5V max. W hen one load 5±0.5V (lamp) is run-out W hen 2 loads 5±0.5V (lamps) is run-out Does not shut down Does not shut down Shut down *1: In the case of low mode, and more than one of SW4 – SW6 in the connection diagramm was open, alarm signal will output 5V. (Please make CN1-8 opening in a high mode) *2 : When all lamps were opened, this inverter has included protective function to stop operation in about 10 seconds Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (3) Version 1.2.1, 15th May 2007