DC-AC INVERTER UNIT

DC-AC INVERTER UNIT
PS-DA0289-285(S) (6.5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC/AC inverter is developed for dual lamps.
Optimized for NEC: NL6448BC33-63D; NL6448BC33-64D
and NL6448BC26-15.
APPLICABLE LCD:
6.4 to 12 inches double lamps
Lamp Voltage 520 Vrms
Lamp Current 5 mArms
Lamp Start Up Voltage 1.450 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Analog dimming /resistor dimming
Max. tolerable component temperatures:
a. Transformer: +105degC; b. Mosfet: +125degC; ( deducting 5°for component tolerance)
CCFL-Fail-Circuit (optional)
Fully compatible with NEC inverter
Very high efficiency
RoHS compliant (S)
Multi-layer PCB with EMI shielding
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxW xH
-10°C ~ +80°C
-30°C ~ +85°C
95 %RH max
114 x 25 x 8 mm
Unit : mm
Weight :20 (g) typ.
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Qty.
1
1
1
Material
UL94V-0 (CEM-3)
53261-0871
SM04(4.0)B-BHS-1-TB
Note
t=1.0mm
MOLEX
JST
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 2.0.1 19th May 2014
DC-AC INVERTER UNIT
PS-DA0289-285(S) (6.5 W DUAL OUTPUTS)
Input side CN1:
Pin No. Symbols
CN 1-1
Vin
CN 1-2
CN 1-3
GND
CN 1-4
Vrmt
CN 1-5
Vbr/Rbr
CN 1-6
Vbr/Rbr
CN 1-7
CN 1-8
Vst
(PRELIMINARY INFORMATION)
Output side CN2:
Pin No.
Symbols
Vhigh1
CN 2-1
Vhigh2
CN 2-2
N.C.
CN 2-3
Vlow
CN 2-4
Ratings
10.8 ~ 13.2V
0V
Ratings
520Vrms (5mArms)
520Vrms (5mArms)
2V
0~0.4V=OFF / 2.5V~Vin=ON
0~2.5V / 0~10kΩ
0~10kΩ
0V/5V (Note 3)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Conditions
Rbr(kΏ)/
Vin (V)
Vbr (V)
Specification
Tu (°C)
Min.
Typ.
Max.
Unit
Note
Output Current
(Brightness max.)
Iout1/2
12±1.2
10 / 2.5
-10~+80
9.0
10
11.0
mArms
For t wo lamps
Output Current
(Brightness min.)
Iout1/2
12±1.2
0/0
-10~+80
-
20
-
%
duty cycle at min.
luminace
Iin1
Iin2
F1
Vopen
12±1.2
12±1.2
12±1.2
10.8 min.
10/2.5
10/2.5
10/2.5
10/2.5
-10~+80
-10~+80
-10~+80
-10~+80
50
1.250
Input Current
Frequency
Open Circuit Voltage
Note 1 :
Note 2 :
Note 3 :
0.52
0.68
1
55
60
1.450 1.700
A
mA
kHz
Vrms
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors as marked on mechanical drawing.
Please provide Vcc before applying any control signals into inverter.
Revere the sequence during power off which is control signal off first then Vcc.
Alarm output is 5V when lamps are open (Optional).
TEST CIRCUIT :
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)