EMERSON-NETWORKPOWER CXE15

CXE15 Series
Single output
DC-DC CONVERTERS
15 W High Efficiency DC-DC Converters
1
• High efficiency topology, 87% typical at 5 V
• Industry standard footprint
• Wide operating temperature, up to and exceeding 65 ˚C
(natural convection)
• 90% to 110% output trim
• No minimum load
• Overvoltage protection
• Remote ON/OFF control
• Available RoHS compliant
The CXE15 is a new high efficiency open frame isolated 15 Watt converter series
in an industry standard footprint. The CXE15 features an input voltage range of 33
Vdc to 75 Vdc and are available in output voltages of 5 V and 3.3 V. The output
voltage on each model is adjustable from 90% to 110% of the nominal value.
Typical efficiencies for the models are 87% for the 5 V and 86% for the 3.3 V. The
CXE15 series also has a remote ON/OFF capability with active high or active low
logic. Overcurrent and overvoltage protection features are included as standard.
With full international safety approval including EN60950 and cUL1950, the CXE15
reduces compliance costs and time to market.
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
90% to 110%
Total error band
(See Note 11)
Line regulation
Low line to high line
0.1% max.
Load regulation
Full load to min. load
0.5% max.
Minimum load
±3.5% max.
0%
Overshoot
None
Undershoot
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (dc power)
Conducted (signal)
Input transients
EN55022 (See Note 3)
Level A
EN55022 (See Note 3)
Level B
EN55022 (See Longform datasheet) Level B
EN61000-4-2 8 kV, 15 kV
EN61000-4-2 6 kV, 8 kV
EN61000-4-3 10 V/m
EN61000-4-6 10 V
EN61000-4-6 10 V
(See Note 8)
ETS 300 132-2, ETR 283
None
Ripple and noise
(See Note 1)
5 Hz to 20 MHz
Transient response
typ. deviation
(See Note 2)
70 mV pk-pk
20 mV rms
100 mV
400 µs recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range
48 Vin nominal
Input current
No load
Remote OFF
35 mA max.
25 mA max.
Input current (max.)
(See Note 4)
0.55 A max. @ Io max.
and Vin = 33-75 Vdc
Input reflected ripple
(See Note 6)
5 mA (pk-pk) typ.
Active high remote ON/OFF
Logic compatibility
ON
OFF
33-75 Vdc
(See Note 10)
Open collector ref to -input
Open circuit or >2 Vdc
<1.2 Vdc
Undervoltage lockout
Power up
Power down
Start-up time
(See Note 7)
Power up
Remote ON/OFF
33 V (typ.)
30 V (typ.)
GENERAL SPECIFICATIONS
Efficiency
See table
Operational insulation
Input/output
Switching frequency
Fixed
1500 Vdc
265 kHz typ.
Approvals and
standards
(See Note 5)
UL/cUL1950, EN60950
TÜV Rheinland
Material flammability
UL94V-0
Weight
MTBF
Representative model:
12 g (0.42 oz)
MIL-HDBK-217F
3,628,000 hours
48S05J @ 48 Vin, 40 °C,
100% load ground benign
BELLCORE 332
>1,500,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Note 9)
Operating ambient
temperature
Non-operating
-40 °C to +65 °C
-40 °C to +120 °C
1.5 ms (typ.)
2.5 ms (typ.)
File Name: cxe15s.pdf Rev: 01 Mar 2006
CXE15 Series
Single output
DC-DC CONVERTERS
15 W High Efficiency DC-DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
POWER
(MAX.)
INPUT
VOLTAGE
OVP
OUTPUT
VOLTAGE
OUTPUT
CURRENT
(MIN.)
OUTPUT
CURRENT
(MAX.)
EFFICIENCY
(TYP.)
LINE
LOAD
MODEL
NUMBER (10,12)
15 W
33-75 Vdc
4 Vdc
3.3 V
0A
4.5 A
86%
0.1%
0.5%
CXE15-48S3V3-SJ
15 W
33-75 Vdc
6 Vdc
5V
0A
3A
87%
0.1%
0.5%
CXE15-48S05J
Notes
Measured as per recommended set-up. See Application Note 116 for
details.
2 di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
3 The CXE15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for details.
4 Recommended input fusing is a 2 A HRC 200 V rated fuse.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Measured with external filter. See Application Note 116 for details.
7 Start-up into resistive load.
8 Signal line assumed < 3 m in length.
9 Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow. See
Application Note 116 for details.
10 Remote ON/OFF (pin 3) and Trim (pin 5) are currently available individually
or together. The CXE-48S05J model includes pins 1, 2, 4, and 6. The
CXE15-48S3V3-SJ features pin 3 with positive logic.
11 This parameter is calculated at worst case line, load, temperature and initial
settings.
12 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
REGULATION
PROTECTION
1
Short circuit
Continuous
Overvoltage
Non-latching clamp
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2, input voltage
and current requirements
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
File Name: cxe15s.pdf Rev: 01 Mar 2006
CXE15 Series
Single output
DC-DC CONVERTERS
15 W High Efficiency DC-DC Converters
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
TOP VIEW
Dimensions in Inches [mm]
1.000 (25.40)
2.000 (50.80)
0.015 (0.38)
0.350 (8.89)
SIDE VIEW
0.600 (15.24)
0.040 (1.02)
0.120 (3.05)
0.600 (15.24)
0.800 (20.32)
Recommended Hole Pattern
0.800 (20.32)
0.100
(2.54)
0.800 (20.32)
0.200
(5.08)
3
Case Outline
6
4
0.400 (10.16)
BOTTOM VIEW
5
1
0.400 (10.16)
0.400 (10.16)
1
.200(5.08) .560 (14.22) 5
.060 (1.52)
2
2
0.200 (5.08)
0.200 (5.08)
4
0.300 (7.62)
3
0.040 (1.016)
0.400 (10.16)
6
Standoff (4 places)
0.600 (15.24)
0.10
(2.54)
Plated Through Hole
0.052-0.06 (1.321-1.40) typical
PIN CONNECTIONS
PIN NUMBER
FEATURE
1
Vin -
2
Vin +
3
On/Off (See Note 10)
4
Vout +
5
Trim (See Note 10)
6
Vout -
International Safety Standard Approvals
UL/cUL 1950 3rd edition. File No. E135734
TÜV
TÜV Rheinland. Certificate No. R2074133
File No. 10401-3336-0916
Datasheet © Artesyn Technologies® 2006
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: 4 Application Note 4 Longform Data Sheet
www.artesyn.com
File Name: cxe15s.pdf Rev: 01 Mar 2006