DATADELAY 1509

1509/1509J
data 3
delay
devices, inc.
MECHANICALLY VARIABLE
DELAY LINE
(SERIES 1509 & 1509J)
FEATURES
•
•
PACKAGES
GND
Ideal for “Set and Forget” applications
Multi-turn adjustment screw
(1509: 20 turns, 1509J: 60 turns)
Stackable for PC board economy
Fits standard 14-pin DIP socket (1509)
20mil x 10mil flat leads (1509)
#20 gauge leads (1509J)
Resolution:
As low as 0.15ns
Dielectric breakdown:
50 Vdc
Temperature coefficient: 200 PPM/°C
•
•
•
•
•
•
•

TAP
1509
IN
1509-xxz
1509J-xxz
xx = Max Delay (TD)
z = Impedance Code
OUT
1509J
GND IN
OUT TAP
FUNCTIONAL DESCRIPTION
PIN DESCRIPTIONS
The 1509- and 1509J-series devices are mechanically variable, passive delay
IN
Signal Input
lines. The signal input (IN) is reproduced at the tap output (TAP), shifted by an
TAP
Variable Output
amount which can be adjusted between 0 and TD, where TD is the device dash
OUT Fixed Output
number. The fixed output (OUT) reproduces the input, delayed by TD, and
GND Ground
must be terminated to match the characteristic impedance of the line, which is
given by the letter code that follows the dash number (See Table). The tap output is unbuffered. The 3dB
bandwidth of the line is given by 0.35 / TR, where TR is the rise time of the line (See Table).
SERIES SPECIFICATIONS
DASH NUMBER SPECIFICATIONS
TAP
IN
Part
Number
1509-05B
1509-20C
1509-20D
1509J-10B
1503J-40C
OUT
GND
Max Dly
(ns)
5
20
20
10
40
TR
(ns)
3
8
8
4
9
Imped
(Ω)
100
200
250
100
200
RDC
(Ω)
0.4
1.0
1.0
0.8
1.5
Functional Diagram
.300
MAX.
.125
2
4
GND
TAP
1.750 MAX.
.187
.460
IN
OUT
1
3
.565
MAX.
.100
G
IN
OUT
TAP
.170
0.760 MAX.
.125
.250
.032
.750
.100
.375
.020
.080
0.600
.010
.080
.080
.300
Package Dimensions - 1509
.080
.062
.062
.200
1.200
.200
Package Dimensions – 1509J
2004 Data Delay Devices
Doc #01012
8/23/04
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1
1509/1509J
PASSIVE DELAY LINE TEST SPECIFICATIONS
TEST CONDITIONS
INPUT:
Ambient Temperature:
Input Pulse:
OUTPUT:
Rload:
Cload:
Threshold:
25oC ± 3oC
High = 3.0V typical
Low = 0.0V typical
Source Impedance:
50Ω Max.
Rise/Fall Time:
3.0 ns Max. (measured
at 10% and 90% levels)
Pulse Width (TD <= 75ns): PWIN = 100ns
Period
(TD <= 75ns): PERIN = 1000ns
Pulse Width (TD > 75ns): PWIN = 2 x TD
Period
(TD > 75ns): PERIN = 10 x TD
10MΩ
10pf
50% (Rising & Falling)
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.
PERIN
PW IN
TRISE
INPUT
SIGNAL
TFALL
VIH
90%
50%
10%
90%
50%
10%
DRISE
VIL
DFALL
TRISE
OUTPUT
SIGNAL
90%
50%
10%
TFALL
VOH
90%
50%
10%
VOL
Timing Diagram For Testing
TAP
OUT
PULSE
GENERATOR
RIN
IN
DEVICE UNDER
TEST (DUT)
IN
OUT
TRIG
TRIG
50 Ω
RIN = ROUT = ZLINE
OSCILLOSCOPE
ROUT
Test Setup
Doc #01012
8/23/04
DATA DELAY DEVICES, INC.
Tel: 973-773-2299
Fax: 973-773-9672
http://www.datadelay.com
2