ETC D34900000824

Du line
Channel Generators
Types FPD 1901, D 3490 0000
®
Fieldbus
•
•
•
•
•
•
•
•
•
•
FPD
Generates 8, 16, 32, 64 or 128 channels
Number of sequences selectable
Quartz-controlled oscillator
Cable compensation
Stop-function
Plug-in type (FPD)
DIN-rail mounting type (D3490) (EN 50022)
LED-indication for supply
LED-indication for supply and Dupline® carrier
AC or DC power supply
D 3490
Product Description
Ordering Key
FPD 1901 024
®
systems, especially suitable
for building installations. Isolation according to IEC
60664/60664 A reinforced.
Increased Dupline® output
power for connection of nonpowered Dupline® transmitters.
Type: Dupline
Channel generator
Supply
Supply
Ordering no.
No. of channels selectable
1, 2 or 3 sequences
Ordering no.
No of channels selectable
1, 2 or 3 sequences
24 VAC
120 VAC
220 VAC
FPD 1901 024
FPD 1901 120
FPD 1901 220
D 3490 0000 024
D 3490 0000 115
D 3490 0000 230
15 to 30 VDC
FPD 1901 824
D 3490 0000 824
Code modules:
1 sequence
2 sequences
3 sequences
FMK 8 to FMK 128
FMK 16-2 to 128-2
FMK 16-3 to 128-3
FMK 8 to FMK 128
FMK 16-2 to 128-2
FMK 16-3 to 128-3
FPD 1901: standard channel
generator for all Dupline® systems. Number of channels
selectable by means of code
module.
D 3490 0000: Standard channel generator for all Dupline®
Installationbus
Type Selection
Input/Output Specifications
Inputs
Function
Open loop voltage
Short-circuit current
Operating time for signal "1"
Operating time for signal "0"
Contact resistance
Cable length
Insulation voltage
Input - Dupline®
Outputs
Number of outputs
Output voltage
Current
Short-circuit protection
FPD 1901 ...
(1, 2 or 3 sequences)
D 3490 0000
(1, 2 or 3 sequences)
1 contact
Stop
12 VDC
5 mA
≤1s
≤ 10 ms
≤ 100 W
≤ 3m
1 contact
Stop
12 VDC
1.25 mA
≤1s
≤ 10 ms
≤ 100 W
≤3m
None
Dupline® carrier
1
8.2 VDC
≤ 40 mA
≤ 600 s
None
Dupline® carrier
1
8.2 VDC
≤ 70 mA
≤ 60 s
Specifications are subject to change without notice (28.09.99)
Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group
1
Du line
FPD 1901, D 3490 0000
®
Fieldbus
Installationbus
Input/Output Specifications (cont.)
Output (cont.)
Output impedance
Sequence time
Code module FMK 8
Code module FMK 16
Code module FMK 32
Code module FMK 64
Code module FMK 128
Distance to transmitters
FPD 1901 ...
(1, 2 or 3 sequences)
D 3490 0000
(1, 2 or 3 sequences)
Time for 1 pulse train (± 1%):
15.63 ms *
23.44 ms *
39.06 ms *
70.31 ms *
132.80 ms *
100% (refer to "Cable Selection")
≤ 25 Ω
Time for 1 pulse train (± 1%)
15.63 ms *
23.44 ms *
39.06 ms *
70.31 ms *
132.80 ms *
100% (refer to "Cable Selection")
* When using 2 or 3 sequences, the sequence time will be 2 or 3 times higher.
Supply Specifications
General Specifications
Power supply AC types
Rated operational voltage
through pins A1 & A2
220
120
024
through term. 21 & 22 230
115
024
Frequency
Voltage interruption
Rated operational power
Rated impulse withstand
voltage
220
120
024
Dielectric voltage
Supply - Dupline® FPD 1901
D 3490 0000
Supply - Inputs FPD 1901
D 3490 0000
Power supply DC types
Rated operational voltage
through pins A1 & A2
824
Ripple
Reverse polarity protection
Current consumption
Inrush current
Rated impulse withstand
voltage
Dielectric voltage
Supply - Dupline®
Supply - Input
Power ON delay
Indication for
Supply ON
Dupline® carrier*
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Humidity (non-condensing)
Mechanical resistance
Shock
Vibration
Dimensions
Material
(see "Technical Information")
Weight
FPD 1901
AC type
DC type
D 3490 0000
Approvals
Overvoltage cat. III (IEC 60664)
230 VAC +6%, -15% (IEC 60038)
120 VAC ± 10% (IEC 60038)
24 VAC ± 10%
230 VAC ± 15% (IEC 60038)
115 VAC ± 15% (IEC 60038)
24 VAC ± 15%
45 to 65 Hz
≤ 40 ms
Typ. 2.5 VA
4 kV
2.5 kV
800 V
None
≥ 4 kVAC (rms)
≥ 2 kVAC (rms)
≥ 4 kVAC (rms)
Overvoltage cat. III (IEC 600664)
15 to 30 VDC (ripple included)
≤3V
Yes
≤ 90 mA
≤1A
≤1s
LED, green
LED, yellow
IP 20
3 (IEC 60664)
-20° to +50°C (-4° to +122°F)
-50° to +85°C (-58° to +185°F)
20 to 80%
15 G (11 ms)
2 G (6 to 55 Hz)
D-housing, H4-housing
200 g
125 g
250 g
CSA, UL (only FPD 1901)
800 V
None
≥ 200 VAC (rms)
* Not applicable to FPD 1901
mission stops immediately,
and 8 VDC is supplied to the
two wires keeping all connected Dupline® modules
ready for operation. When
the stop-function is deactivated, a delay of approx. 2 s
elapses before the signal
transmission is resumed.
The stop input must be acti-
vated whenever new Dupline® modules are to be connected to the system or
whenever Dupline® modules
need to be removed or
replaced.
The selection of 2 or 3 sequences means that 2 or 3
consecutive signals of a
transmitter must show iden-
Mode of Operation
The channel generators generate pulse trains and synchronize the transmission
signals for an entire system
of Dupline® modules. At the
same time they supply nonpowered Dupline® transmitters. If the stop-function is
activated (pins 2 & 3 interconnected), the signal trans-
2
tical status until the channel
generator changes the duty
cycle for the respective
channel. This change of
duty cycle causes the receivers to change their status.
Specifications are subject to change without notice (28.09.99)
Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group
Du line
FPD 1901, D 3490 0000
®
Fieldbus
Installationbus
Mode of Operation (cont.)
Note:
- Do not use 2 or 3 sequences if analog modules or
counters are connected to
the system.
- Do not use 3 sequences if
the modem interface D9091
... is used in the system.
- The transmission distance
of a Dupline® network is
reduced by 33% when
using 2 or 3 sequences, compared to the figures given
under "Cable Selection".
In Dupline® systems with digital transmitters and receivers
the use of 2 or 3 sequences is
only recommended in cases
of extremely long cabling in
high noise level environment.
Application of 2 or 3 sequences results in absolutely
correct transmission but also
in a slow reaction time for the
system.
HF disturbance that is induced to the Dupline® may be
suppressed by interconnec-
Note: It is highly recommended to place the channel generator in the middle of a
Dupline® system.
tion of pins 4 & 6 (FPD 1901)
or terminals 4 & 1 (D 3490
0000. For inductive cables a
separate capacitor of less
than 1 µF may be mounted
between pins 3 & 6 (FPD
1901) or terminals 1 & 2 (D
3490 0000). But in the majority of cases the cable appears
to be capacitive requiring no
additional capacitor.
Operation Diagram
Power supply
Dupline® carrier
Stop function
Wiring Diagrams
FPD 1901 AC supply
D 3490 0000
Stop
Noise
suppression
S: signal wire
Stop
AC
Power Supply
FPD 1901 824 DC supply
Noise
suppression
Noise
suppression
S: signal wire
~ ~
(+) (-)
Power supply
Accessories
Stop
Socket◊
Socket cover
Hold down spring◊
Front mounting bezel
DIN-rail for D 411
D 411
BB 5
HF
FRS 2
FMD 411
For further information refer to "Accessories".
S: signal wire
+ DC
Power Supply
Specifications are subject to change without notice (28.09.99)
Dupline® is a registered trademark. A product of the CARLO GAVAZZI Group