OPTREX DMC16128NY-LY

First Edition
May 12, 1998
LCD Module Specification
Approved by
Production Div.
Checked by
Quality Assurance Div.
Checked by
Design Engineering Div.
Prepared by
Production Div.
Final Revision
*******
Type No.
DMC16128NY-LY
Table of Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
General Specifications .............................................................................2
Electrical Specifications...........................................................................3
Optical Specifications ..............................................................................6
I/O Terminal.............................................................................................8
Test..........................................................................................................10
Appearance Standards............................................................................11
Code System of Production Lot ..........................................................14
Type Number .........................................................................................14
Applying Precautions .............................................................................14
Handling Precautions .............................................................................15
Revision History
Rev.
Date
DMC16128NY-LY (AK)
Page
No.98-0102
Comment
OPTREX
OPTREX CORPORATION
Page 1/15
1.General Specif ications
Operating Temp.
: min. 0℃ ~ max. 50℃
Storage Temp.
: min. -20℃ ~ max. 70℃
Display Format
: 16 characters × 1 lines
Display Fonts
: 5 × 7 dots + cursor
Viewing Area
: 99.0 (W) × 13.3 (H) mm
Outline Dimensions
: 122.0 (W) × 33.0 (H) × 15.7 max. (D) mm
Weight
:80g max.
LCD Type
: NTD-7088
( STN / Neutral-mode / Transmissive )
Viewing Angle
: 6:00
Backlight
: LED Backlight / Yellow-green
Drawings
: Dimensional Outline
DMC16128NY-LY (AK)
No.98-0102
OPTREX
( 1 character )
UE-35101A
OPTREX CORPORATION
Page 2/15
2.Electrical Specif ications
2.1.Absolute Maximum Ratings
VSS=0V
Parameter
Supply Voltage
Symbol
Conditions
Min.
Max.
Units
VCC-VSS
-
-0.3
7.0
V
VCC-VEE
-
0
13.0
V
VI
-
-0.3
VCC+0.3
V
(Logic)
Supply Voltage
(LCD Drive)
Input Voltage
2.2.DC Characteristics
Ta=25℃, VSS=0V
Parameter
Supply Voltage
Symbol
Conditions
Min.
Typ.
Max.
Units
VCC-VSS
-
4.5
-
5.5
V
(Logic)
Supply Voltage
VCC-VEE
Shown in 3.1
V
(LCD Drive)
High Level
VIH
VCC=5.0V±10%
2.2
-
VCC
V
VIL
VCC=5.0V±10%
0
-
0.6
V
VOH
IOH=-0.205mA
2.4
-
VCC
V
VOL
IOL=1.2mA
0
-
0.4
V
ICC
VCC-VSS=5.0V
-
1.5
2.5
mA
Input Voltage
Low Level
Input Voltage
High Level
Output Voltage
Low Level
Output Voltage
Supply Current
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 3/15
2.3.AC Characteristics
VCC=5.0V±10%
Parameter
Symbol
Conditions
Min.
Max.
Units
Enable Cycle Time
tCYC
Fig.1, 2
500
-
ns
Enable Pulse Width
PWEH
Fig.1, 2
230
-
ns
Enable Rise/Fall Time
tEr, tEf
tAS
tAH
tDSW
tDHW
tDDR
tDHR
Fig.1, 2
-
20
ns
Fig.1, 2
40
-
ns
Fig.1, 2
10
-
ns
Fig.1
80
-
ns
Fig.1
10
-
ns
Fig.2
-
160
ns
Fig.2
5
-
ns
Address Setup Time
Address Hold Time
Write Data Setup Time
Write Data Hold Time
Read Data Delay Time
Read Data Hold Time
RS
VIH
VIH
VIL
VIL
tAS
R/W
tAH
VIL
VIL
PWEH
tEr
tEf
VIH
E
VIH
VIL
VIL
tDSW
VIH
VIL
DB0~DB7
VIL
tDHW
VIH
VIL
Valid Data
tCYC
Fig.1
RS
Write Operation Timing
VIH
VIH
VIL
VIL
tAS
R/W
tAH
VIH
VIH
PWEH
tEr
E
tEf
VIH
VIH
VIL
VIL
tDDR
tDHR
VOH
VOL
DB0~DB7
VIL
Valid Data
VOH
VOL
tCYC
Fig.2
DMC16128NY-LY (AK)
No.98-0102
Read Operation Timing
OPTREX
OPTREX CORPORATION
Page 4/15
2.4.Lighting Specifications
2.4.1.Absolute Maximum Ratings
Ta=25℃
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units
Foward Current
IF
Note 1
-
-
180
mA
Reverse Voltage
VR
-
-
-
8
V
LED Power Dissipation
PD
-
Note 1 : Refer to the foward current derating curve.
-
-
0.8
W
IF (mA)
180
105
0
25
50
Ta (℃)
2.4.2.Operating Characteristics
Ta=25℃
Parameter
Symbol
Conditions
Min.
Typ.
Max.
Units
Foward Voltage
VF
IF=90mA
3.8
4.1
4.4
V
Luminance of
L
IF=90mA
35
-
-
cd/㎡
Backlight Surface
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 5/15
3.Optical Specif ications
3.1.LCD Driving Voltage
Parameter
Symbol
Recommended
LCD Driving Voltage
Note 1 :
VCC-VEE
Conditions
Min.
Typ.
Max.
Units
Ta= 0℃
-
-
5.0
V
Ta=25℃
4.2
4.5
4.8
V
Note 1
Ta=50℃
4.0
V
-
-
Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of
minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and
response time are not guaranteed over the entire range.
3.2.Optical Characteristics
Ta=25℃, 1/16 Duty, 1/5 Bias, VD=4.5V (Note 4), θ= 0゚, φ=-゚
Parameter
Contrast Ratio
Symbol
Conditions
Min.
Typ.
Max.
CR
θ= 0゚, φ=-゚
-
8
-
Note 1
Viewing Angle
Response
Units
Shown in 3.3
Rise
Note 2
TON
-
-
120
200
ms
Time
Decay Note 3
TOFF
200
300
ms
-
-
Note 1 : Contrast ratio is definded as follows.
CR = LOFF / LON
LON : Luminance of the ON segments
LOFF : Luminance of the OFF segments
Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON
signal is applied.
Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF
signal is applied.
Note 4 : Definition of Driving Voltage VD
VD=VCC-VADJ-VBE
Assuming that the typical driving waveforms shown below are applied to the LCD Panel at
1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is definded
as follows.
VD = (Vth1+Vth2) / 2
Vth1 : The voltage VO-P that should provide 50% of the satulation level in the luminance at
the segment which the ON signal is applied to.
Vth2 : The voltage VO-P that should provide 50% of the satulation level in the luminance at
the segment which the OFF signal is applied to.
VO-P
( B-2 )×VO-P / B
1 / ( fF×A )
1 / fF
〈ON SIGNAL〉
DMC16128NY-LY (AK)
No.98-0102
〈OFF SIGNAL〉
OPTREX
OPTREX CORPORATION
Page 6/15
3.3.Definition of Viewing Angle and Optimum Viewing Area
・Point ● shows the point where contrast ratio is measured. : θ= 0゚, φ=-゚
・Driving condition : 1/16 Duty, 1/5 Bias, VD=4.5V, fF=84.4Hz
90゚
45゚
135゚
θ
φ
10 20 30 40 50
180゚
90゚
(φ= 0゚)
θ
φ
180゚
225゚
0゚
315゚
270゚
270゚
・Area
shows typ. CR≧2
3.4.System Block Diagram
Temperature Chamber
Rotation Table (θ,φ)
Photometer
#1980A WB
LCD
φ
Optical Fiber
θ
Computer
Control Unit &
Waveform Generator
Halogen bulb
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 7/15
4.I/O Terminal
4.1.Pin Assignment
CN1
No.
Symbol
Level
Function
1
VSS
-
Power Supply (0V, GND)
2
VCC
-
Power Supply for Logic
3
VEE
-
Power Supply for LCD Drive
4
RS
H/L
Register Select Signal
5
R/W
H/L
Read/Write Select Signal
6
E
H/L
Enable Signal (No pull-up Resister)
7
DB0
H/L
Data Bus Line / Non-connection at 4-bit operation
8
DB1
H/L
Data Bus Line / Non-connection at 4-bit operation
9
DB2
H/L
Data Bus Line / Non-connection at 4-bit operation
10
DB3
H/L
Data Bus Line / Non-connection at 4-bit operation
11
DB4
H/L
Data Bus Line
12
DB5
H/L
Data Bus Line
13
DB6
H/L
Data Bus Line
14
DB7
H/L
Data Bus Line
15
ANODE
-
LED Anode Terminal
16
CATHODE
-
LED Cathode Terminal
H : Read
L : Write
4.2.Example of Power Supply
It is recommended to apply a potentiometer for the contrast adjust due to the tolerance
of the driving voltage and its temperature dependence.
VCC (+Voltage)
VCC
VR
MODULE
VSS
VSS (0V)
VEE
VR=10~20K Ω
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 8/15
4.3.Block Diagram
8
COM 8
~
DB7
DB0
E
RS
Control LSI
COM 8
LCDP
HD44780
R/W
16 characters × 1 lines
or equivalent
VEE
SEG 40
VCC
SEG 40
VSS
ANODE
LED Backlight
CATHODE
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 9/15
5.Test
No change on display and in operation under the following test condition.
No.
Parameter
Conditions
Notes
1
High Temperature Operating
50℃±2℃, 96hrs (operation state)
2
Low Temperature Operating
0℃±2℃, 96hrs (operation state)
3
3
High Temperature Storage
70℃±2℃, 96hrs
4
4
Low Temperature Storage
-20℃±2℃, 96hrs
3, 4
5
Damp Proof Test
40℃±2℃, 90~95%RH, 96hrs
3, 4
6
Vibration Test
Total fixed amplitude : 1.5mm
5
Vibration Frequency : 10~55Hz
One cycle 60 seconds to 3 directions of X, Y, Z for
each 15 minutes
7
Shock Test
To be measured after dropping from 60cm high on
the concrete surface in packing state.
F
E
G
B
D
C
A
60cm
Concrete Surface
Dropping method corner dropping
A corner : once
Edge dropping
B,C,D edge : once
Face dropping
E,F,G face : once
Note 1 : Unless otherwise specified, tests will be conducted under the following condition.
Temperature : 20±5℃
Humidity
: 65±5%
Note 2 : Unless otherwise specified, tests will be not conducted under functioning state.
Note 3 : No dew condensation to be observed.
Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity
after removed from the test chamber.
Note 5 : Vibration test will be conducted to the product itself without putting it in a container.
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 10/15
6.Appearance Standards
6.1.Inspection conditions
The LCD shall be inspected under 40W white fluorescent light.
The distance between the eyes and the sample shall be more than 30cm.
All directions for inspecting the sample should be within 45゚against perpendicular line.
45゚
6.2.Definition of applicable Zones
A Zone
Bezel Flame
B Zone
C Zone
A Zone : Active display area
B Zone : Area from outside of "A Zone" to validity viewing area
C Zone : Rest parts
A Zone + B Zone = Validity viewing area
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 11/15
6.3.Standards
No.
1
Parameter
Black and
Criteria
(1) Round Shape
White Spots,
Foreign Substances
Zone
Acceptable Number
Dimension (mm)
A
B
C
D ≦ 0.1
*
*
*
0.1 < D ≦ 0.2
5
5
*
0.2 < D ≦ 0.3
0
1
*
0.3 < D
0
0
*
D = ( Long + Short ) / 2
* : Disregard
(2) Line Shape
Zone
X(mm)
Acceptable Number
Y(mm)
A
B
C
-
0.02≧W
*
*
*
2.0≧L
0.03≧W
3
3
*
1.0≧L
0.04≧W
1
2
*
1.0≧L
0.05≧W
0
2
*
-
0.05<W
X : Length
Y : Width
In the same way (1)
* : Disregard
Total defects shall not exceed 5.
2
Air Bubbles
(between glass
& polarizer)
Zone
Dimension (mm)
Acceptable Number
A
B
C
*
*
*
0.15< D ≦0.3
2
3
*
0.3 < D ≦0.5
1
2
*
0.5 < D ≦1.0
0
1
*
D ≦0.15
* : Disregard
Total defects shall not exceed 3.
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 12/15
No.
3
Parameter
The Shape of Dot
Criteria
(1) Dot Shape (with Dent)
0.15≧
As per the sketch of left hand.
(2) Dot Shape (with Projection)
Should not be connected to next dot.
(3) Pin Hole
X
(X+Y) / 2≦0.2mm
Y
(Less than 0.1mm is no counted.)
Total defects shall not exceed 5.
4
Polarizer Scratches
Not to be conspicuous defects.
5
Polarizer Dirts
If the stains are removed easily from LCDP surface, the module is not
defective.
6
Color Variation
DMC16128NY-LY (AK)
Not to be conspicuous defects.
No.98-0102
OPTREX
OPTREX CORPORATION
Page 13/15
7.Code System of Production Lot
The production lot of module is specified as follows.
□
□
□
□
□
□
Factory Number (Numeral)
Factory Code (Alphabet)
Production Week (1~5)
Production Month (1~9, X, Y, Z)
Production Year (Lower 2 digits)
8.Type Number
The type number of module is specified on the back of module as follows.
DMC16128
NY-LY
Stamp
Etching or Printing
9.Applying Precautions
Please contact us when questions and/or new problems not specified in this specifications arise.
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 14/15
10.Handling Precautions
Optrex Products are designed for use in ordinary electronic devices such as business machines,
telecommunications equipment, measurement devices and etc..
Optrex Products are not designed, intended, or authorized for use in any application in which the failure of
the product could result in a situation where personal injury or death may occur. These applications
include, but are not limited to, life-sustaining equipment, nuclear control devices, aerospace equipment,
devices related to hazardous or flammable materials, etc. (If Buyer intends to purchase or use the Optrex
Products for such unintended or unauthorized applications, Buyer must secure prior written consent to
such use by a responsible officer of Optrex Corporation.) Should Buyer purchase or use Optrex Products
for any such unintended or unauthorized application (without such consent), Buyer shall indemnify and
hold Optrex and its officers, employees, subsidiaries, affiliates and distributors harmless against all claims,
costs, damages and expenses, and reasonable attorney's fees, arising out of, directly or indirectly, any
claim of personal injury or death associated with such unintended or unauthorized use, even if such claim
alleges that Optrex was negligent regarding the design or manufacture of the part.
1) LCD may be broken because it is made of glass.
2) Polarizer is a soft material and can easily be scratched.
3) Please avoid static electricity.
① Please be sure to ground human body and electric appliances during work.
② It is preferable to use conductive mat on table and wear cotton clothes or conduction processed fiber.
Synthetic fiber is not recommended.
③ Please slowly peel off protective film, because static electricity may be charged.
4) If it is necessary to store LCD modules for a long time, please comply with the following procedures.
If storage condition is not satisfactory, display (especially polarizer) may be deteriorated or soldering
I/O terminals may become difficult (some oxide is generated at I/O terminals plating).
① Store as delivered by Optrex
② If you store as unpacked, put in anti-static bag, seal its opening and store where it is not subjected to
direct sunshine nor fluorescent lamp.
③ Store at temperature 0 to +35℃ and at low humidity. Please refer to our specification sheets for
storage temperature range and humidity condition.
5) The module does not contain excess current limiter.
Please design the limiter to cut excess current in your power supply circuit.
6) Liquid crystal may be leaked when display is broken. Never taste it. If your hands or clothes touch it,
please immediately wash using soap.
7) The connection between the bezel and VSS (GND) is not specified in the module.
(Some module do not maintain connection between them.)
Please consult OPTREX to specify the connection.
Optrex shall not be responsible for any infringement of industrial property rights of third parties in any
country arising out of the application or use of Optrex Products, except which directly concern the
structure or production of such products.
DMC16128NY-LY (AK)
No.98-0102
OPTREX
OPTREX CORPORATION
Page 15/15