DS2711/DS2712 Loose Cell NiMH Chargers www.maxim-ic.com PIN CONFIGURATION DESCRIPTION The DS2711 and DS2712 are ideal for in-system or stand-alone charging of 1 or 2 AA or AAA NiMH “loose” cells. Temperature, voltage, and charge time are monitored to provide proper fast charging control algorithms for nickel metal hydride (NiMH) batteries. Battery tests are included to detect defective or inappropriate cells such as alkaline primary batteries. The DS2711/DS2712 support series and parallel topologies, with independent monitoring and control of each cell. Charging of NiCd chemistry cells is also supported. 16 SO (150 mil) / TSSOP (4.4 mm) FEATURES See Table 1 for Ordering Information. Charge 1 or 2 NiMH Cells Detect and Avoid Charging Alkaline Cells Precharge Deeply Depleted Cells PIN DESCRIPTION Fast Charge NiMH with -ΔV Termination PIN 1 2 3 NAME CC1 CC2 LED1 4 VSS 5 6 7 8 9 10 11 12 13 14 15 16 LED2 CSOUT VN1 VN0 DMSEL CTST TMR VDD THM1 THM2 VP1 VP2 Sensitivity of 2mV (typ) Monitor Voltage, Temperature, and Time for Safety and Secondary Termination Regulate Charge Current: Linear Control (DS2711) Switch-Mode Control (DS2712) Drive PMOS or PNP-Type Pass Element or Switch, or an Optocoupler Compatible with Popular Optocouplers and Integrated Primary Side PWM Controllers Small 16-Pin SO or TSSOP Package FUNCTION Cell 1 Charge-Control Output Cell 2 Charge-Control Output Cell 1 Status Ground Reference and Chip-Supply Return Cell 2 Status, Mode-Select Input Current-Sense Output Current-Sense + Input Current-Sense - Input Display-Mode Select Cell Test Threshold Set Charge Timer Set Chip-Supply Input (4.0V to 5.5V) Cell 1 Thermistor Input Cell 2 Thermistor Input Cell 1 Positive-Terminal Sense Input Cell 2 Positive-Terminal Sense Input APPLICATIONS Desktop/Stand-Alone Chargers (AAA/AA) Digital Still Cameras Music Players Games Toys 1 of 15 120808 DS2711/DS2712: Loose Cell NiMH Charger Table 1. ORDERING INFORMATION PART DS2711Z DS2711Z/T&R DS2712Z DS2712Z/T&R DS2711Z+ DS2711Z+T&R DS2712Z+ DS2712Z+T&R DS2711E+ DS2711E+T&R DS2712E+ DS2712E+T&R MARKING DS2711 DS2711 DS2712 DS2712 DS2711 DS2711 DS2712 DS2712 DS2711 DS2711 DS2712 DS2712 PIN-PACKAGE 16 SO 16 SO, Tape-and-Reel 16 SO 16 SO, Tape-and-Reel 16 SO 16 SO, Tape-and-Reel 16 SO 16 SO, Tape-and-Reel 16 TSSOP 16 TSSOP, Tape-and-Reel 16 TSSOP 16 TSSOP, Tape-and-Reel + Denotes lead-free package. ABSOLUTE MAXIMUM RATINGS* Voltage on All Pins Relative to VSS Voltage on DMSEL Continuous Sink Current CC1, CC2, LED1, LED2 and CSOUT Operating Temperature Range Storage Temperature Range Soldering Temperature -0.3V to +6V VDD + 0.3V 20mA -40°C to +85°C -55°C to +125°C See IPC/JEDECJ-STD-020 *This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability. RECOMMENDED DC OPERATING CONDITIONS (4.0V ≤ VDD ≤ 5.5V; TA = -20°C to +70°C.) PARAMETER Supply Voltage Input Voltage Range SYMBOL VDD CONDITIONS (Note 1) LED2, DMSEL MIN 4.0 -0.3 TYP MAX 5.5 +5.5 UNITS V V TYP MAX UNITS Operating mode 250 500 μA VDD rising (Note 1) 3.5 3.9 V DC ELECTRICAL CHARACTERISTICS (4.0V ≤ VDD ≤ 5.5V, TA = -20°C to +70°C, unless otherwise noted.) PARAMETER Supply Current, VDD SYMBOL IDD UVLO Threshold VUVLO UVLO Hysteresis VUHYS Output-Voltage Low, CC1, CC2, LED1, LED2 Output-Voltage Low, CSOUT Leakage Current, CC1, CC2, LED1, LED2, CSOUT Threshold Voltage, -ΔV Termination Mode Test Current, DMSEL, LED2 VOL1 VOL2 CONDITIONS VDD falling from above VUVLO VDD = 5.0V, IOL = 20mA (Note 1) VDD = 5.0V, IOL = 20mA (Note 1) MIN 40 1.0 V 1.25 V +1 μA 2.0 3.0 mV 5 15 μA 0.75 ILKG VDD = 5.0V, Output inactive -1 V-ΔV After tTHO 1.0 IMTST (Notes 2, 3) 2 of 15 mV DS2711/DS2712: Loose Cell NiMH Charger PARAMETER Input Logic-High, DMSEL, LED2 Input Logic-Low, DMSEL, LED2 Input Leakage Current, DMSEL Threshold Voltage, Cell Test Threshold Voltage, Cell Voltage Low Threshold Voltage, Cell Voltage Max1 Threshold Voltage, Cell Voltage Max2 Threshold Voltage Delta Threshold Voltage, Thermistor - Min Threshold Voltage, Thermistor - Max Threshold Voltage, Thermistor - Stop Threshold Current, TMR Pin Suspend Presence Test Current, VP1, VP2 SYMBOL CONDITIONS VIH (Note 1) VIL (Note 1) IIL1 After power-up mode select, DMSEL = VDD or VSS -1 RCTST = 80kΩ 85 VCTST VBAT-MAXΔ CC1 = CC2 = high-Z (Note 4) CC1 = CC2 = high-Z (Note 4) CC1, CC2 active (Note 4) VBAT-MAX2 - VBAT-MAX1 (Note 5) VTHM-MIN (Notes 1, 4, 6) VTHM-MAX (Notes 1, 4, 6) VTHM-STOP (Notes 1, 4, 6) VBAT-LOW VBAT-MAX1 VBAT-MAX2 Parallel: VDD ≥ 4.0V, Series: VDD ≥ 4.5V Reverse Leakage Current, VP1, VP2 ILKGR VDD = 0V, VP1 = 1.5V, VP2 = 3.0V Current-Sense Reference Voltage VIREF (Note 1, 4, 7) V μA 100 115 mV 0.9 1.0 1.1 V 1.55 1.65 1.75 V 1.64 1.75 1.86 V 90 100 110 mV 0.30 VDD x 0.73 VDD x 0.33 VDD x 0.29 0.36 0.1 0.5 μA 10 15 μA 2 μA V V V 125 mV -6% +6% % 1.5 Ω-1 0.9 GM DS2712 (Note 8) 10 Ω-1 DS2712, 2mV over/underdrive DS2712 UNITS +1 DS2711 (Note 8) VHYS-COMP MAX V GM tPDLY TYP 0.2 ITMR-SUS IPTST Gain, Current-Sense Error Amp Gain, Current-Sense Comparator Propagation Time, Current-Sense Comparator Hysteresis, CurrentSense Comparator MIN VDD 0.2V 22 0.25 μs 24 26 mV TYP MAX UNITS ELECTRICAL CHARACTERISTICS: TIMING (4.0V ≤ VDD ≤ 5.5V, TA = -20°C to +70°C, unless otherwise noted.) PARAMETER SYMBOL Internal Timebase Period tBASE Internal Timebase Accuracy Duty Factor, Series Fast Charge Duty Factor, Series Precharge/Top-Off Duty Factor, Parallel Fast Charge CONDITIONS MIN 0.96 -10 +10 CC1 0.969 CC1 0.250 CC1, CC2 0.484 3 of 15 s % DS2711/DS2712: Loose Cell NiMH Charger PARAMETER Duty Factor, Parallel Precharge/Top-Off Duty Factor, Maintenance Charge SYMBOL Cell Test Interval tCTST Precharge Time-Out tPCHG CONDITIONS MIN TYP CC1, CC2 0.125 CC1, CC2 0.0156 VCELL < VBAT-MIN MAX UNITS 31 s 34 minutes 4 minutes Fast-Charge Termination Hold-Off Period Fast-Charge Flat Voltage Time-Out tFLAT VCELL not increasing 16 minutes Charge Timer Period tCTMR RTMR = 100kΩ 2.5 h tTHO Charge Timer Accuracy Charge Timer Range Note 1: Note 2: Note 3: Note 4: Note 5: Note 6: Note 7: Note 8: RTMR = 100kΩ tCTMR-RANGE -5 +5 % 0.5 10 h Voltages relative to VSS. IMTST current is applied as a source current and as a sink current within 5ms after power-up. When operating in two-cell-series charge configuration, the DMSEL pin must have less than 50pF of external load capacitance for proper operation. If the load capacitance is greater than 50pF, a resistor voltage divider should be used to maintain DMSEL at VDD / 2. Specification applicable during charge cycle with TA = 0°C to +70°C. VBAT-MAX1 and VBAT-MAX1 are generated from the same reference. Their ranges never overlap. VTHM-MIN, VTHM-MAX, and VTHM-STOP are fixed ratios of VDD. Their ranges never overlap. Tested with ICSOUT = -1mA. Gain tested with 1mV step with ICSOUT = -1mA. 4 of 15 DS2711/DS2712: Loose Cell NiMH Charger Figure 1. BLOCK DIAGRAM 5 of 15 DS2711/DS2712: Loose Cell NiMH Charger Figure 2. STATE DIAGRAM VDD < VPOR -VHYS (asynchronously from anywhere) POR VDD > VPOR (3.7V) Standby power CCx = Hi-Z LEDx = Hi-Z t < PCTimeout CCx = Hi-Z LEDx = No Battery PreCHG OR VBAT < 1.65V VBAT > 1.75V CCx = Active 12.5% Par., 25% Ser. LEDx = Charging VBAT < 1V t > PCTimeout OR T < 0 OR T > 50 OR VBAT > 1.75V VBAT > 1V AND t < PCTimeout AND T < 50C FAULT Standby power CCx = Hi-Z LEDx = Fault CCx = Hi-Z LEDx = Charging Fast CHG FAIL: VON - VOFF > VCTST VBAT > 1.75V 32 clock interval CCx = Active 48% Par., 97% Ser. LEDx = Charging delta-V detect OR t > Fast Timeout t < Topoff Timeout VBAT > 1.75V (asynchronously from anywhere) t < 1s Cell Test PASS t < Fast Timeout Presence TEST VBAT > 1.75V OR T < 0C OR T > 45C Topoff CHG CCx = Active 12.5% Par., 25% Ser. LEDx = Charging T > 50 T > 50 OR t > Topoff Timeout 6 of 15 MAINT CCx = Active 1/64 LEDx = Maintenance DS2711/DS2712: Loose Cell NiMH Charger DETAILED DESCRIPTION Charge Algorithm Overview A charge cycle begins in one of three ways: with the application of power to the DS2711 with cell(s) already inserted, with the detection of cell insertion after power-up, or when exiting suspend mode with cell(s) inserted. The charge cycle begins with precharge qualification to prevent fast charging of deeply depleted cells or charging under extreme temperature conditions. precharging is performed at a reduced rate until each cell reaches 1V. The algorithm proceeds to a fast-charge phase, which includes cell tests to avoid accidental charging of alkaline cells or NiMH cells that are worn-out or damaged. Fast charging continues as long as the cell temperature(s) are less than 50°C (based on THM1, THM2 voltages) and the open-circuit cell voltage(s) are between 1.0V and 1.75V. Fast charging terminates by the -ΔV (negative delta voltage) method. The top-off charge phase follows to completely charge the cells. After the top-off charge timer expires, the maintenance charge phase continues indefinitely to keep the cells at a full state of charge. Maximum voltage, temperature, and charge-time monitoring during all charge phases act as secondary or safety termination methods to provide additional protection from overcharge. Each cell is monitored independently, and in parallel mode the charge phase of each cell is independently controlled. Series Charge Configuration The DS2711/DS2712 series configuration supports one or two-slot stand-alone and one or two cell in-system chargers. The single-cell-series mode charges one cell while the two-cell-series mode charges two series cells. Since the cells are charged in series, cell sizes should not be mixed in the series configuration. In the application example in Figure 3, charge current is gated to the battery cells by a PNP transistor under the control of the CC1 pin of the DS2711. Current regulation is performed outside of this example schematic using the current-sense feedback provided by the DS2711 CSOUT pin. The DS2712 can also be used in this circuit to provide switch-mode control on the CSOUT pin. RSNS = 0.125Ω sets the charge source current, ICHG, to 1A. In series mode, the effective charge current is 0.969 x ICHG = 969mA. Figure 3. SERIES CONFIGURATION WITH EXTERNAL CURRENT REGULATION 7 of 15 DS2711/DS2712: Loose Cell NiMH Charger Parallel Charge Configuration The parallel configuration supports two slot stand-alone chargers. Charge pulses are fed alternately to each cell under the control of the CC1 and CC2 pins so the charge regimes occur in parallel. The duty cycle on CC1 and CC2 are independent of one another. Transitions from precharge to fast charge, fast charge to top-off, and top-off to maintenance occur independently for each cell. The configuration shown in Figure 4 is for charging two cells with the current-sense feedback regulating the charge source to 2A (RSNS = 0.068Ω). The effective charge current for each cell is 2A x 0.484 = 0.968A. A charger with battery holders designed to accept either AA or AAA cell sizes can be constructed with the current-sense resistance split between two separate resistors so each cell type (AA or AAA) is charged at a different rate. Mechanical design of the holders is required to prevent insertion of more than one cell in each slot. The holder design must also prevent electrical contact with reverse polarity insertion. Figure 4. PARALLEL CONFIGURATION WITH EXTERNAL CURRENT REGULATION The series or parallel charge configuration is programmed by strapping LED2 in the low, high, or high-Z (float) state during power-up. In this example and the following one, the parallel charge mode is selected by pulling LED2 pin high during power-up. This is accomplished in this example by the LED and 270Ω resistor. In applications where only one LED is used, a 100kΩ pullup resistor is recommended. See Table 3. CHARGE MODE SELECTION on page 13 for additional configuration programming information. 8 of 15 DS2711/DS2712: Loose Cell NiMH Charger DS2712 Parallel Charge Configuration with Switch-Mode Charge Current Regulation The example in Figure 5 uses the DS2712 to regulate charge current as a switching (buck) regulator. ICHG is set to 2A using RSNS = 0.056Ω. The effective charge current for each cell is ICHG x 0.484 = 968mA. The CSOUT comparator output switches OFF when the voltage across the sense resistor goes above 0.125V and back ON when the voltage drops below 0.100V. In this mode, the operating frequency is determined primarily by the value of the inductor, the hysteresis, the input voltage, and the voltage on the cells. In some cases, a damping network may be required to prevent overshoot with the batteries removed. Figure 5. PARALLEL CONFIGURATION WITH SWITCH-MODE CURRENT REGULATION (DS2712 ONLY) 9 of 15 DS2711/DS2712: Loose Cell NiMH Charger Undervoltage Lockout (UVLO) The UVLO circuit serves as a power-up and brownout detector by monitoring VDD to prevent charging until VDD rises above VUVLO, or when VDD drops below VUVLO - VHYS. If UVLO is active, charging is prevented, the state machine is forced to the RESET state, and all charge timers are reset. A 10μs deglitch circuit provides noise immunity. Internal Oscillator and Clock Generation An internal oscillator provides the main clock source used to generate timing signals for internal chip operation. The precharge timer, hold-off timers, and timings for CC1/CC2 operation and cell testing are derived from this timebase. In case the internal clock should ever fail, a watchdog detection circuit halts charging. The watchdog safety circuit and charge timer set by the TMR pin are derived from separate oscillators than the main clock source. Current-Sense Amplifier (DS2711) An error amplifier block provides several options to regulate the charge current. The 20mA open-drain output can drive a PMOS or PNP pass element for linear regulation, or the output can drive an optocoupler for isolated feedback to a primary-side PWM controller. The VN0 pin is a remote-sense return and should be connected to the grounded side of the sense resistor using a separate, insulated conductor. Figure 6. Current-Sense Amplifier Response 1.20 0 1.00 -50 Phase -100 0.60 -150 0.40 -200 0.20 -250 0.00 10 1 10 2 10 3 10 4 10 5 10 6 10 7 Phase Gain Gain 0.80 -300 Frequency (Hertz) The open-loop amplifier response shown in Figure 6 was measured with ICSOUT = -1mA. An error signal between the current-sense signal (across a sense resistor) and the 0.125V internal reference is produced so the voltage across the sense resistor is maintained at VIREF in a closed-loop circuit. Current-Sense Comparator (DS2712) The comparator in the DS2712 switches between ON and OFF and is capable of driving a PNP bipolar or a PMOS transistor, enabling the use of a switched-mode power stage. Hysteresis on the comparator input provides noise rejection. In the closed-loop regulation circuit of Figure 5, the comparator regulates voltage across the sense resistor to a DC average of: VRSNS = VIREF - 0.5 x VHYS-COMP = 0.125V 10 of 15 DS2711/DS2712: Loose Cell NiMH Charger Charge Timer The charge timer monitors the duration of charge in fast and top-off charge phases, and is reset at the beginning of each phase. The time-out period is set with an external resistor connected from the TMR pin to VSS. Resistors can be selected to support fast-charge time-out periods of 0.5 to 10 hours and top-off charge time-out periods of 0.25 to 5 hours. If the timer expires in fast-charge, the timer count is reset and charging proceeds to the top-off charge phase. The top-off time-out period is half of the fast charge time-out period. If the timer expires in top-off, charging proceeds to the maintenance phase. The programmed charge time approximately follows the equation: t = 1.5 x R / 1000 (time in minutes) Suspend Suspension of charge activity is possible by floating the TMR pin. The CC1 and CC2 outputs become high-Z and the charge timer stops. The state machine and all timers are reset to their presence test conditions. Temperature Sense Connecting an external 10kΩ NTC thermistor between THM1 or THM2 (THMx) and VSS, and a 10kΩ bias resistor between VDD and THMx allows the DS2711 to sense temperature. To sense the temperature of the battery cells, locate the thermistor close to the body of the battery cell so THM1 monitors the temperature of cell-1 and THM2 monitors the temperature of cell-2. Alternatively, the thermistor can sense ambient temperature by locating it away from the cells. THM1 and THM2 can be connected together to sense temperature using a single thermistor and bias resistor. The temperature qualification function can be defeated by connecting THM1 and THM2 to a single resistor-divider supplying a voltage between the Thermistor-Min and Thermistor-Max threshold voltages. Several recommended 10kΩ thermistors are shown in Table 2. Min, Max Temperature Compare The voltage thresholds of the THMx inputs (VTHM-MIN, VTHM-MAX) are set to allow fast charging to start if 0°C < TA < 45°C when using the recommended 10kΩ bias and 10kΩ thermistor. If fast charging is in progress, and the voltage on THMx reaches VTHM-STOP, fast charging stops and the maintenance phase begins. Table 2. THM1, THM2 THRESHOLDS TEMPERATURE (°C) THM THRESHOLD RATIO OF VDD THERMISTOR RESISTANCE (Ω) Semitec 103AT-2 MIN MAX STOP 0.73 0.33 0.29 27.04k 4.925k 4.085k 0°C 45°C 50°C Figure 7. CELL VOLTAGE SENSE POINTS 11 of 15 Fenwal 197-103LAG-A01 173-103LAF-301 4°C 42°C 47°C DS2711/DS2712: Loose Cell NiMH Charger Cell Voltage Monitoring In the 2-cell series mode, the voltage difference between VP2 and VP1 is used to determine the Vcell2 voltage in the two-cell series stack. The voltage difference between VP1 and VN1 is used to determine the Vcell1 voltage. In the 1-cell series mode, the difference between VP1 and VN1 is used as the cell voltage. VP2 can be left floating in the 1-cell series mode. In parallel mode, the difference between VP2 and VN1 is used for the Vcell2 voltage, and the difference between VP1 and VN1 is used for Vcell1 voltage. Individual cell voltages are monitored for minimum and maximum values, using the VBAT-MIN, VBAT-MAX1 and VBAT-MAX2 threshold limits. Upon inserting a cell or power-up with cells inserted, cell voltages must be less than the VBAT-MAX1 threshold before charging begins. The VBAT-MIN threshold determines whether a precharge cycle should precede the fast charge cycle, and when to transition from precharge to fast charge. Once fast charging commences, cell voltages are compared to the VBAT-MAX2 threshold once per second. The comparison occurs while the charge control pin (CC1 or CC2) controlling current to the cell is active (low). When the charge control pin is active so charge is applied to the cell, the cell voltage is referred to as the VON voltage. When the charge-control pin is inactive, the cell voltage is referred to as the VOFF voltage. If VBAT-MAX2 is exceeded in fast charge, charging is halted and a fault condition is displayed. While fast charge is in progress, cell voltage measurements are stored and compared to future measurements for charge termination and cell test purposes. Two types of tests are performed to detect primary alkaline and lithium cells or defective NiMH or NiCd secondary cells. Cells are tested individually in the series and parallel configurations, so that a single improper or defective cell can be detected quickly. In the series configuration, a single defective cell will terminate charge for both cells, whereas the parallel mode continues charging the good cell and stops charging the defective cell. VCTST is set by the resistance from the CTST pin to ground. The nominal sensitivity of 100mV is set by connecting an 80kΩ resistor between CTST and VSS. The detection threshold can be set from 32mV to 400mV. The following formula approximates the setting for the detection threshold. VCTST = 8000/R (value in volts) -ΔV and Flat Voltage Termination During fast charge, -ΔV detection is performed by comparing successive voltage measurements for a drop of 2mV in the cell voltage. A hold-off period for -ΔV detection begins at the start of fast charging and prevents false termination in the first few minutes of the charge cycle. Once the hold-off period expires, cell voltage measurements are acquired every 32 clock cycles (during the CCx off time). When a newly acquired voltage measurement is greater than any previous one, the new value is retained as the maximum value. When the cell voltage no longer increases, the maximum value is retained and compared against subsequent values. If the cell voltage drops by the -ΔV threshold, V-ΔV, (2mV typ), fast charging is terminated. If the cell voltage remains flat such that the maximum value persists for a period of 16 minutes (tFLAT), fast charge terminates and top-off charging begins. Top-Off and Maintenance In top-off mode, the charger scales the cell current to 25% of the fast charge current. The charge timer is reset and restarted with a time-out period of one half the fast-charge duration. When the charge timer expires in top-off, the charger enters maintenance and delivers 1/64 of the charge source current to the cells. Maintenance charge continuous until power is removed, the cell(s) are removed or the DS2711/DS2712 is cycled into and out of suspend mode by floating the TMR pin. Selecting the Charge Mode The charge mode configuration is selected by testing the LED2 pin during startup. An internal current source tests the state of the LED2 pin by pulling up and pulling down on the pin to determine if it is high, low, or floating. The recommended pullup or pulldown resistor value (if used) is 100kΩ. In the parallel charging circuit diagrams on page 8, no resistor is shown. The current path through the LED and 270Ω resistor is sufficient to pull the LED2 pin high at power-up to select the parallel mode. Refer to the mode test current (IMTST) specification in the Electrical Characteristics table to select other pullup values. 12 of 15 DS2711/DS2712: Loose Cell NiMH Charger Table 3. CHARGE MODE SELECTION LED2 PIN STRAPPING MODE Low 1-Cell Series Floating 2-Cell Series High Parallel CC1 and CC2 Outputs The CC1 and CC2 operate as open-drain outputs that drive active low to connect the charge source to the battery cell. During charge, the behavior of the CC1 and CC2 outputs depends on the charge-mode configuration. In parallel mode, CC1 and CC2 are driven low in alternating time slots. The charge source is loaded by just one cell during any time slot. In the 1-cell and 2-cell series mode, only CC1 is driven. Except for the periodic performance of impedance and -ΔV tests, series mode charging is continuous during the fast charge phase rather than pulsed in parallel mode. Parallel Mode Fast Charge Referring to Figure 4. PARALLEL CONFIGURATION WITH EXTERNAL CURRENT REGULATION, CC1 controls the PNP switch that gates current to the cell in slot 1. CC2 controls the PNP switch that gates current to the cell in slot 2. During fast charge, current is gated to each slot sequentially, with charge pulses occurring in alternating time frames. The cell in one slot charges while the other relaxes and the effective fast-charge current is 48.4% of the magnitude set by the charge-source current limit. The parallel configuration skips a charge pulse every 32 clock cycles to facilitate independent testing of the open- and closed-circuit cell voltages (VOFF and VON, respectively). Since the charge regime of each cell is independent, one cell may complete a charge phase before the other. The more fully charged cell of a pair inserted at the same time could terminate fast charge by -ΔV, then charge in top-off while the less charged cell continues in fast charge. In the case of an improper or faulty cell (e.g., alkaline) being inserted along with a proper cell (NiMH or NiCd), charging of the faulty cell would be stopped, while the proper cell is charged to full. Series Mode Fast Charge Referring to Figure 3. SERIES CONFIGURATION WITH EXTERNAL CURRENT REGULATION, CC1 controls the PNP switch that gates current to the cell(s). In series mode, 1 or 2 cells can be charged, depending on whether the 1-cell or 2-cell series mode has been selected. During fast charge, current is gated to the cell(s) almost continuously, with the effective fast-charge current approximately equal to current limit of the charge source. The series configuration deactivates CC1 briefly every 32 clock cycles to facilitate independent testing of VOFF and VON of each cell. The one second deactivation makes the duty factor 0.969 and therefore the effective current equals approximately 97% of the charge-source current limit. In the 2-cell series mode, the characteristics of each cell are evaluated individually; however charging stops if either cell is determined to be improper or faulty. In the 1-cell charge series mode, CC1 gates the charge current as in the 2-cell series mode. The cell voltage is monitored between VP1 and VN1, and temperature is monitored with THM1. The VP2 and THM2 pins can be left floating in the 1-cell series mode. EXAMPLE CAPACITIES AND CHARGE RATES Parallel Charging Example: A 1700mAH cell is charged using a 1A regulated charge source. During fast charge, the cell is charged at a duty factor of 0.484 and receives an effective charge current of 0.484A. In terms of C-rate, this is 484mA/1700mAh = 0.285°C (or C/3.5). During precharge and top-off, the duty factor is 0.125 (i.e., 1/8), for an effective average current of 125mA, corresponding to a C-rate of 125/1700 = 0.073C (or C/13.6). Similarly, in maintenance mode, the duty factor is 0.0156 (i.e., 1/64) and the C-rate is 15.6/1700 = 0.0092 ( or C/109). The C-rates for charging 3 different cell capacities using a 500mA and a 1000mA current source are shown in Table 4. 13 of 15 DS2711/DS2712: Loose Cell NiMH Charger Table 4. PARALLEL CONFIGURATION, EACH CELL MODE Cell Capacity Fast Precharge/Top-Off Maintenance CURRENT LIMIT 500mA 900mAH 1700mAH 2200mAH C/3.72 C/7.02 C/9.08 C/14.4 C/27.2 C/35.2 C/115 C/218 C/282 CURRENT LIMIT 1000mA 900mAH 1700mAH 2200mAH C/1.86 C/3.51 C/4.54 C/7.20 C/13.6 C/17.6 C/57.6 C/109 C/141 Series and Single Cell Charging Example: In the series and single-cell modes, the effective fast charge current is equal to 0.969 times the regulated current limit and the top-off current is 0.25 times the regulated current. The maintenance mode is identical to the parallel charging rate, that is, 1/64 times the regulated current. The C-rates for charging 3 different cell capacities using a 500mA and a 1000mA current source are shown in the following table. Table 5. SERIES CONFIGURATION, EACH CELL MODE Cell Capacity Fast Precharge/Top-Off Maintenance CURRENT LIMIT 500mA 900mAH 1700mAH 2200mAH C/1.86 C/3.51 C/4.54 C/7.20 C/13.6 C/17.6 C/115 C/218 C/282 CURRENT LIMIT 1000mA 900mAH 1700mAH 2200mAH C/0.93 C/1.75 C/2.27 C/3.60 C/6.80 C/8.80 C/57.6 C/109 C/141 LED1 and LED2 Outputs, MODE-Select Input Open-drain outputs LED1 and LED2 pull low to indicate charge status. When inactive, the outputs are high impedance. LED1 displays the status for the cell monitored by VP1 and LED2 displays the status for the cell monitored by VP2. The LED pins drive low in three “blink” patterns to annunciate the charge status. Table 6 summarizes the LED operation in each display mode (DM0, DM1, DM2) for each charge condition. In parallel mode, LED1 indicates the status of the cell whose positive terminal is connected to VP1 and LED2 indicates the status of the cell whose positive terminal is connected to VP2. In series mode, LED1 indicates the charge status for both cells since they are charged in series. Table 6. DISPLAY PATTERNS BY DISPLAY MODE AND CHARGE ACTIVITY DISPLAY MODE CHARGE ACTIVITY DMSEL PIN NO BATTERY PRE/FAST/TOPOFF CHARGING MAINTENANCE FAULT DM0 Low High-Z Low 0.80s Low 0.16s High-Z 0.48s Low 0.48s High-Z DM1 Float High-Z Low High-Z 0.16s Low 0.16s High-Z DM2 High High-Z 0.80s Low 0.16s High-Z Low 0.16s Low 0.16s High-Z High-Z = High Impedance Package Information For the latest package outline information and land patterns, go to www.maxim-ic.com/packages. 14 of 15 DS2711/DS2712: Loose Cell NiMH Charger REVISION HISTORY REVISION DATE 120808 DESCRIPTION Changed Figure 2 to include “T <0” as a condition to move from Pre-Charge to Fault state. 15 of 15 PAGES CHANGED 6