OMRON E3CLD112M

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)
E3C-LDA Series
• All three beam types provide ample long-distance
detection of 1,000 mm for Diffuse Reflective Models.
• Coaxial Retroreflective Models provide detection
performance equivalent to through-beam sensors,
simplifying Sensor installation.
• Industry-first variable focal point and optical axis
alignment mechanisms. Optimize for workpieces and
improve inspection quality.
• Drive the laser with an Amplifier the same size as a
Digital Fiber Amplifier.
Ordering Information
■ Sensor Heads
Sensing method
Diffuse reflective
Focus
Model number
Remarks
Spot
E3C-LD11
Mounting a Beam Unit (sold separately) allows the use of line and area
beams.
Line
E3C-LD21
This model number is for the set consisting of the E39-P11 mounted to
the E3C-LD11.
Area
E3C-LD31
This model number is for the set consisting of the E39-P21 mounted to
the E3C-LD11.
Coaxial retroreflective Spot (variable)
(with MSR)
E3C-LR11 (See note.) Mounting a Beam Unit (sold separately) allows the use of line and area
beams.
Spot (2.0-mm fixed dia.) E3C-LR12 (See note.) --Note: Select a reflector (sold separately) according to the application.
■ Amplifier Units
Amplifier Units with Cables
Item
Appearance
Functions
Model
NPN output
Advanced
models
PNP output
Twin-output
models
Area output, self-diagnosis,
differential operation
E3C-LDA11
E3C-LDA41
External-input
models
Remote setting, counter, dif- E3C-LDA21
ferential operation
E3C-LDA51
ATC function
ATC (Active Threshold Con- E3C-LDA11AT
trol)
E3C-LDA41AT
Analog output
Analog output
E3C-LDA41AN
E3C-LDA11AN
Amplifier Units with Connectors
Item
Appearance
Functions
Model
NPN output
Advanced
models
PNP output
Twin-output
models
Area output, self-diagnosis,
differential operation
E3C-LDA6
E3C-LDA8
External-input
models
Remote setting, counter, dif- E3C-LDA7
ferential operation
E3C-LDA9
ATC function
ATC (Active Threshold Con- E3C-LDA6AT
trol)
E3C-LDA8AT
E3C-LDA Series Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)
1
■ Amplifier Unit Connectors
(Order Separately)
Item
Appearance
Master Connector
Cable
length
No. of conductors
2m
Slave Connector
■ Accessories (Order Separately)
Beam Units
Model
4
E3X-CN21
2
E3X-CN22
Applicable
Sensor Head
Appearance
Focus
E3C-LD11
E3C-LR11
■ Mobile Console
(Order Separately)
Appearance
Model
Model
Line
E39-P11
Area
E39-P21
Line
E39-P31
Area
E39-P41
Reflectors
Remarks
Type
Appearance
Model
E3X-MC11-SV2
Mobile Console with
(model number of set) Head, Cable, and AC
(See notes 1 and 2.) adapter provided as
accessories
Standard Effective area: 23 × 23
mm
E39-R12
E3X-MC11-C1-S
Mobile Console
Standard Effective area: 7 × 7 mm
E39-R13
E3X-MC11-H1
Head
Short-distance transparent detection
Effective area: 23 × 23 mm
E39-R14
E39-Z12-1
Cable (1.5 m)
Sheet (cuttable) Effective area:
195 × 22 mm
E39-RS4
Sheet (cuttable) Effective area:
108 × 46 mm
E39-RS5
Note 1. Use the E3X-MC11-SV2 Mobile Console for the E3C-LDA-series
Amplifier Units. Other Mobile Consoles cannot be used.
2. The E3X-MC11-SV2 is an upgraded version of the E3X-MC11-S,
to which a corresponding Sensor Head is added. (The E3XMC11-SV2 and E3X-MC11-S are compatible.)
Specifications
■ Ratings/Characteristics
Sensor Heads
Item
Diffuse reflective
E3C-LD11
E3C-LD21
Coaxial retroreflective (with MSR)
E3C-LD31
E3C-LR11
E3C-LR11 + E39P31
E3C-LR11 + E39P41
Light source
(emission wavelength)
Red semiconductor laser diode (650 nm), 2.5 mW max. (JIS standard: Class 2, FDA standard: Class II)
Sensing distance
High-resolution mode: 30 to 1,000 mm
Standard mode: 30 to 700 mm
Super-high-speed mode: 30 to 250 mm
(See note 1.)
Beam size (See note 3.) 0.8 mm max.
(at distances
up to 300 mm)
33 mm (at
150 mm)
7m
5m
2m
(See note 2.)
33 × 15 mm (at 0.8 mm max.
150 mm)
(at distances
up to 1,000
mm)
E3C-LR12
1 mW max. (JIS
standard Class
1)
1,700 mm,
1,300 mm
700 mm
(See note 2.)
900 mm
700 mm
400 mm
(See note 2.)
7m
5m
2m
(See note 2.)
28 mm (at 150 mm)
28 × 16 mm (at
150 mm)
2.0 mm dia. (at
distances up to
1,000 mm)
Functions
Variable focal point mechanism (beam size adjustment) (See note 4.), optical axis adjustment mechanism (axis adjustment)
Indicators
LDON indicator: Green; Operation indicator: Orange
Ambient illumination
(receiver side)
3,000 lx (incandescent lamp)
Ambient temperature
Operating: −10°C to 55°C; Storage: −25°C to 70°C (with no icing or condensation)
Ambient humidity
Operating/storage: 35% to 85% (with no condensation)
Vibration resistance
(destruction)
10 to 150 Hz with double amplitude of 0.7 mm, in X, Y, and Z directions for 80 min each
Degree of protection
IEC 60529: IP40
Materials
Case and cover:
Front surface filter:
Weight (packed)
Approx. 85 g
ABS
Acrylic resin
Case and cover:
ABS
Front surface filter: Glass
Approx. 100 g
Note 1. Values are sensed for white paper.
2. These values apply when a E39-R12 Reflector is used. The MSR function is built-in. The reflected light from the object being measured may affect the sensing
accuracy, so adjust the threshold value before use.
3. The beam radius is the value for the middle measurement distance and indicates a typical value for the middle sensing distance. The radius is defined by light
intensity of 1/e2 (13.5%) of the central light intensity.
Light will extend beyond the main beam and may be affected by conditions surrounding the object being measured.
4. The E3C-LR12 has a fixed beam size (the focus point cannot be changed).
2
E3C-LDA Series Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)
Amplifier Units
Type
External-input models
Model NPN output E3C-LDA21
Item
PNP output E3C-LDA51
Twin-output models
ATC-output models
Analog-output models
E3C-LDA7
E3C-LDA11
E3C-LDA6
E3CLDA11AT
E3C-LDA6AT
E3C-LDA11AN
E3C-LDA9
E3C-LDA41
E3C-LDA8
E3CLDA41AT
E3C-LDA8AT
E3C-LDA41AN
Supply voltage
12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption
1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
ConON/OFF output
trol output
Analog output
Load power supply voltage: 26.4 VDC max.; NPN/PNP (depends on model) open collector
Load current: 50 mA max.; residual voltage: 1 V max.
ReSuper-high-speed
sponse mode
time
High-speed mode
Functions
---
Control output
Voltage output: 1 to 5 VDC (connected load 10 kΩ min.)
Temperature characteristics
0.3% F.S./°C
Response time/Repeat accuracy
Super-high-speed mode: 100 µs/
4.0% F.S.
High-speed mode: 250 µs/4.0%
F.S.
Standard mode: 1 ms/2.0% F.S.
High-resolution mode: 4 ms/2.0%
F.S.
80 µs for operation and reset
100 µs for operation and reset
250 µs for operation and reset
Standard mode
1 ms for operation and reset
High-resolution
mode
4 ms for operation and reset
Differential detection
Switchable between single edge and double edge detection mode.
Single edge: Can be set to 250 µs, 500 µs, 1 ms, 10 ms, or 100 ms.
Double edge: Can be set to 500 µs, 1 ms, 2 ms, 20 ms, or 200 ms.
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments,
and 1 to 5 s set in 1-s increments)
Timer function
Zero-reset
Negative values can be displayed.
Initial reset
Settings can be returned to defaults as required.
Mutual interference
prevention
Possible for up to 10 Units. (See note.)
Counter
Switchable between up
counter and down counter.
Set count: 0 to 9,999,999
I/O settings
External input setting (Se- Output setting (Select from
channel 2 output, area outlect from teaching, power
tuning, zero reset, light OFF, put, or self-diagnosis.)
or counter reset.)
---
Analog output setting (Offset voltOutput setting (Select from
channel 2 output, area output, age can be adjusted.)
self-diagnosis, or ATC error
output.)
Digital display
Select from digital incident level + threshold or six other patterns.
Display orientation
Switching between normal/reversed display is possible.
Ambient temperature range
Operating:
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Insulation resistance
20 MΩ at 500 VDC
Storage:
Groups of 1 to 2 Amplifiers: −25°C to 55°C
Groups of 3 to 10 Amplifiers: −25°C to 50 °C
Groups of 11 to 16 Amplifiers: −25°C to 45°C
−30 °C to 70°C (with no icing)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 min.
Vibration resistance
Destruction: 10 to 150 Hz, 0.7-mm double amplitude for 80 min each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2, 3 times each in X, Y, Z directions
Degree of protection
IP50 (IEC 60529)
Connection method
Prewired cable or wire-reducing connector
Weight (packed state)
With prewired cable: Approx. 100 g
With wire-reducing connector: Approx. 55 g
Materi- Case
als
Cover
Polybutylene terephthalate (PBT)
Polycarbonate
Note: Communications are disabled if super-high-speed mode is selected, and the mutual interference prevention function and the communications function for the Mobile Console will not function.
E3C-LDA Series Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)
3
Dimensions
Sensor Head
E3C-LD11
E3C-LR11
12.8
33
12.8
39
25
25
33
27.7
Two, 3.2-dia.
mounting holes
5.1
20
R 4.8
25 18.8
Two, R 2.6
3.1
27
Connector
Round
und vinyl-clad cable, 1.8 dia. × 2 conductors
(cross-sectional area of conductor: 0.15 mm2)
Standard length: 2 m
18
Reflector
Amplifier Unit
E39-R12/-R14
E39-R13
E3C-LDA11
10
30
12
76
24 17.2
45 37
32
This document provides information mainly for selecting suitable models. Please read the Instruction Sheet
carefully for information that the user must understand and accept before purchase, including information on
warranty, limitations of liability, and precautions.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. E338-E1-04
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Application Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107
Printed in Japan
1205-0.2M (1202) (M)
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR
STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the product.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent
the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This catalog shall not be copied for sales or promotions without permission.
This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.
Cat. No. E338-E1-04
OMRON Corporation
2007. 3
In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company