OMRON E5C2

Temperature Controller
E5C2
DIN-sized (48 x 48 mm) Temperature
Controller with Analog Setting
• Compact, low-cost Temperature Controller.
• Incorporates proportional control and reset adjustment function.
• Consecutive mounting possible using mounting adapter.
• Incorporates a plug-in socket, thus allows to DIN-track and flush
mounting.
Model Number Structure
■ Model Number Legend
E5C2- @ @ @ @
1
2
3
4 5
4. Input type
K:
K-type thermocouple
J:
J-type thermocouple
P:
Platinum resistance thermometer (Jpt100)
G:
Thermistor (THE)
5. Special type
Blank: Standard type
D, DIN: Special types
Temperature
Controller
1. Model name
2. Control output
R:
Relay
Q:
Voltage
3. Control method
20: ON-OFF control
40: P control
Ordering Information
■ Temperature Controllers
Setting
method
Indication
method
Control mode
Output
Model
Thermocouple
K (CA)
Chromel vs.
alumel
Analog setting No indication
J (IC)
Iron vs.
constantan
Platinum resistance
thermometer
Pt100
Thermistor
THE
ON/OFF
Relay
E5C2-R20K
E5C2-R20J
E5C2-R20P-D
E5C2-R20G
P
Relay
E5C2-R40K
E5C2-R40J
E5C2-R40P-D
---
Note: When placing an order, specify the standard temperature range and supply voltage in addition to the model number.
(e.g., E5C2-R20K 0°C to 200°C 100/110 VAC)
■ Accessories (Order Separately)
Name
Model
Front Connecting Socket
P2CF-08
Back Connecting Socket (for flush mounting)
P3G-08
Front Connecting Socket with Finger Protection
P2CF-08-E
Protective Cover (for finger protection)
Y92A-48G
Temperature Controller
E5C2
I-5
Specifications
■ Ratings
Supply voltage
100/110/120 VAC (common), 200/220/240 VAC (common) (See note.)
50/60 Hz (common)
Operating voltage range
90% to 110% of rated supply voltage
Power consumption
Approx. 2 VA
Input
Thermocouple (with sensor burnout detection circuit), platinum resistance thermometer, or thermistor
Control mode
ON/OFF or P control
Setting method
Analog setting
Indication method
No indication
Control output
Relay output: SPDT, 3 A at 250 VAC, resistive load (switching capacity: 330 VA)
Note: Specify either 100/110/120 VAC or 200/220/240 VAC when ordering.
■ Input Ranges
Input
Thermocouple
K (CA)
Chromel vs. alumel
Range
Platinum resistance
thermometer
Thermistor (see note 2)
Pt100
THE
J (IC)
Iron vs. constantan
°C
0 to 200 (5),
0 to 300 (10),
0 to 400 (10),
0 to 600 (20),
0 to 800 (20),
0 to 1,000 (25),
0 to 1,200 (25)
0 to 200 (5),
0 to 300 (10),
0 to 400 (10)
–50 to 50 (2),
–20 to 80 (2),
0 to 50 (1),
0 to 100 (2),
0 to 200 (5),
0 to 300 (10),
0 to 400 (10)
–50 to 50 (2) (6 kΩ at 0°C),
0 to 100 (2) (6 kΩ at 0°C),
50 to 150 (2) (30 kΩ at 0°C),
100 to 200 (2) (550 Ω at 200°C),
150 to 300 (2) (4 kΩ at 200°C)
°F
32 to 392 (10),
32 to 572 (20),
32 to 752 (20),
32 to 1,112 (40),
32 to 1,472 (50),
32 to 1,832 (50),
32 to 2,192 (50)
32 to 392 (10),
32 to 572 (20),
32 to 752 (20)
32 to 212 (5),
32 to 392 (10)
---
Note: 1. Values in ( ) are the minimum unit.
2. Values in ( ) are the thermistor resistive value.
■ Characteristics
Setting accuracy
±2% FS max.
Hysteresis
Approx. 0.5% FS (fixed)
Proportional band
3% FS (fixed)
Control period
Approx. 20 s
Reset range (see note 1)
5 ±1% FS min.
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between charged terminals and uncharged metallic parts
Vibration resistance
Malfunction: 10 to 55 Hz, 0.15-mm single amplitude for 10 min each in X, Y, and Z directions
Destruction: 16.7 Hz, 2-mm double amplitude for 2 hrs each in X, Y, and Z directions
Shock resistance
Malfunction: 147 m/s2, 3 times each in 6 directions
Destruction: 294 m/s2, 3 times each in 6 directions
Life expectancy
Electrical:
Ambient temperature
Operating: –10°C to 55°C (with no icing or condensation)
Ambient humidity
Operating: 45% to 85%
Degree of protection
Front panel: IEC standard IP40 (see note 2)
Terminals: IEC standard IP00
Weight
Approx. 200 g (with flush-mounting adapter)
100,000 operations min. (3 A at 110 VAC, resistive load)
Note: 1. No reset function is incorporated by any E5C2 model with ON/OFF control.
2. The model number of the special watertight cover conforming to IP66, NEMA4 is Y92A-48B.
I-6
Temperature Controller E5C2
Nomenclature
Temperature setting knob
Operation indicator
RESET adjustment shaft
No reset function is incorporated by any
E5C2 model with ON/OFF control.
Operation Indicator
Indicator
Red
Output
Lit
ON
Not lit
OFF
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement
(Bottom View)
48 x 48
44.8 x 44.8
Flush-mounting
adapter
Temperature
Controller
Dimensions with Flush-mounting Adapter (Accessory),
and Back Connecting Socket (Sold Separately)
Panel
Y92F-30 Flush-mounting adapter
P3G-08 Back connecting socket
Tightening screw
(96) (see note)
Note: 109 mm for US08 Back Connecting Socket
Panel Cutout
Side-by-side Mounting
of N Controllers
N
2
3
4
5
6
L
93+1
0
141+1
0
189+1
0
237+1
0
285+1
0
60 min.
Note: 1. Recommended panel thickness is 1 to 4 mm.
2. Close side-by-side mounting is possible (in a single direction).
Temperature Controller
E5C2
I-7
Accessories (Order Separately)
P2CF-08 Front Connecting Socket
Terminal Arrangement/
Internal Connections
(Top View)
Eight, M3.5 x 7.5 sems
Mounting Holes
Two, 4.5 dia. or Two, M4
70 max.
Two,
4.5-dia.
holes
Note: Can also be
mounted to a
DIN track.
50 max.
20 max.
Note: A finger-protection model (P2CF-08-E) is also available.
P3G-08 Back Connecting Socket (for Flush Mounting)
Terminal Arrangement/
Internal Connections
(Bottom View)
27 dia.
Note: A Protective Cover for finger protection (Y92A-48G) is also available.
Protective Cover Y92A-48
The protective cover protects the front panel, particularly the setting
section, against dust, dirt, and water drip. It also prevents the set values from being altered due to accidental contact with the setting
keys.
Appearance
Model
Y92A-48B
Installation
■ Connections
Input
Output
Connect a thermocouple, the E52-THE@ Thermistor or platinum
resistance thermometer to the E5C2 as shown in the following illustration.
If the load circuit is a heating control system, be sure to connect the
load to terminals 4 and 5. If the load circuit is a cooling control system, be sure to connect the load to terminals 4 and 6. If the heating
control system is connected to terminals 4 and 6 or the cooling control system is connected to terminals 4 and 5, the temperature of the
heating control system or cooling control system will be abnormal
and a serious accident may result.
Platinum resistance
thermometer input
Relay output
If the E5C2 is in frequent operation, such as proportional operation,
add an appropriate external relay to the E5C2 by considering the
capacity of the load and the life of the relay.
Thermocouple input
Power Supply
Thermistor input
Power supply
100/110, 200/220,
110/120, 220/240 VAC
50/60 Hz
If a single power supply is used for the E5C2 and the load, the supply
voltage of the power supply may vary greatly when the load is open
or closed if the capacity of the power supply is not large enough.
Make sure that the capacity of the power supply is large enough so
that the supply voltage range will be always from 90% to 110% of the
rated supply voltage.
The E5C2 operates at either 50 or 60 Hz.
I-8
Temperature Controller E5C2
Precautions
Mounting
Track Mounting (E5C2 with P2CF-08)
When mounting two or more E5C2 models with track-mounting sockets, leave a space of approximately 20 mm on both sides of the sockets where hooks are located.
Hook
Duct
P2CF-08
20
Panel
Flush Mounting
Insert E5C2 into the square hole of the panel and insert an adapter
from the back so that there will be no space between E5C2 and the
panel. Then, secure the E5C2 with a screw.
Tightening screw
Temperature
Controller
The P3G-08 can be wired in the same way as the P2CF-08.
Dismounting
If flush mounted, loosen the screw of the adapter and disengage the
hooks for dismounting.
Temperature Setting
Do not turn the temperature setting knob of the E5C2 with excessive
force, otherwise the stopper of the knob may break.
Others
Do not remove the housing of the E5C2, otherwise the housing may
break.
To clean the surface of the E5C2, use a soft cloth wet with neutral
detergent or alcohol. Do not use any organic solvent, such as paint
thinner or benzine, strong acid or strong alkali to clean the surface of
the E5C2, otherwise the surface of the E5C2 will become damaged.
Temperature Controller
E5C2
I-9
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. H081-E1-02
I-10
In the interest of product improvement, specifications are subject to change without notice.
Temperature Controller E5C2