ETC ECSSM23A10S

Timers
Symmetrical Recycler
Type ECS
•
•
•
•
•
•
•
•
•
SCREW
Fail-safe two-wire connection
Low-cost
Multi-voltage: 24-230 VAC
2 types: Recycler (Start OFF)
Recycler (Start ON)
Time range: 0.5 s - 10 m
Knob-adjustable time setting
Output: SCR 10-500 mA (screws) and SCR 10-700mA
(Fast-ON)
For mounting on DIN-rail in accordance with
DIN/EN 50 022
22.5 mm small Euronorm housing
FASTON
Product Description
Ordering Key
Small, low cost monofunction timer with adjustable
time setting. 2-wire connection for easy and fail-safe use
(see diagram). For mounting
on DIN-rail or directly on sur-
face by screw. The timer is
used e.g. with industrial
relays or 3-phase contactors.
Housing
Function
Small E-line
Output
Power supply
Type
Time range
Fast-ON connection
ECS S M23 A 10S F
Type Selection
Mounting
Output
Time range
Connection
Supply: 24 - 230 VAC
For DIN-rail
or for screw
SCR
0.5 - 10 s
Screws
SCR
0.1 - 1 m
Screws
SCR
1 - 10 m
Screws
ECS S M23 A 10S
ECS S M23 B 10S
ECS S M23 A 1M
ECS S M23 B 1M
ECS S M23 A 10M
ECS S M23 B 10M
(OFF)
(ON)
(OFF)
(ON)
(OFF)
(ON)
SCR
0.5 - 10 s
Fast-ON
SCR
0.1 - 1 m
Fast-ON
SCR
1 - 10 m
Fast-ON
ECS S M23 A 10S F
ECS S M23 B 10S F
ECS S M23 A 1M F
ECS S M23 B 1M F
ECS S M23 A 10M F
ECS S M23 B 10M F
(OFF)
(ON)
(OFF)
(ON)
(OFF)
(ON)
For DIN-rail
or for screw
Time Specifications
Time ranges
10 S
1M
10 M
Time range accuracy
Repeat accuracy
Time variation
Within rated power supply
and ambient temperature
Ratio TOFF/TON
Reset
Time and output
Output Specifications
0.5 - 10 s
0.1 - 1 m
1 - 10 m
Max. setting: actual time
≥ max. set time
min. setting: actual time
≤ min. set time
≤ 0.2%
≤ 0.1%/V
≤ 0.2%/°C
T
1 ≤ OFF ≤ 1.1
TON
Output
Output current
Maximum load current
(screw terminals)
(Fast-ON connection)
Maximum current for 100 ms
(screw terminals)
(Fast-ON connection)
Minimum load current
Leakage current
Voltage drop
SCR
500 mA
700 m
5.5 A
7A
10 m
≤ 3.5 mA @ 230 V
typ.: 2 m
≤ 8 VAC
typ.: 5 VAC @ 50 mA
Supply Specifications
Power supply interruption
≥ 200 ms
Power supply
Rated operational voltage
Rated insulation voltage
Specifications are subject to change without notice (24.07.06)
Overvoltage cat. III (IEC 60664)
(IEC 60038)
24-230 VAC, -10/+15%
None
1
ECS
General Specifications
Power ON delay
Power OFF delay
Environment
Degree of protection
Pollution degree
Operating temperature
Storage temperature
Weight
Housing
Dimensions Screw terminals
Fast-ON terminals
Material
≤ 100 ms
≥ 200 ms
Approvals
CE Marking
EMC
IP 20
3
-20° to +50°C (-4° to +122°F)
-30° to +80°C (-22° to +176°F)
50 g
UL, CSA
Yes
Electromagnetic
Compatibility
Acc. to IEC 60801-4
Acc. to IEC 60801-5
Immunity
22.5 x 56 x 49 mm
22.5 x 56 x 44 mm
ABS
Wiring Diagram
L
N
Operation Diagram
Power supply
ECS (Typ A)
ECS (Typ B)
Dimensions
SCREW
FAST-ON
4x f3.4
2
15
49
44
20
22.5
15
56
47.4
49
56
22.5
42
49
4x f3.4