Timers Asymmetrical Recycler Types DCB01, PCB01 DCB01 • Time range 0.1 s to 100h • 4 knob selectable functions Aa - Asymmetrical recycler ON first Ab - Asymmetrical recycler OFF first Sh - One shot time function Dt - Two state delay on operate (2 relays versions only) • Selection of time range by DIP switches • Knob adjustable time setting Automatic start • Output: 1 or 2 x SPDT relay • For mounting on DIN rail in accordance with DIN/EN 50 022 or Plug-in • 22.5 mm Euronorm or 36 mm plug-in module housing • Combined AC and DC power supply voltage • LED indication for relay status and power supply ON PCB01 Product Description Ordering key Combined function timer with asymmetrical recycler, one shot time and two state delay on operate functions. Individual selection of the time ranges from 0.1 s to 100 h. Housing Function Type Item number Output Power Supply For mounting on DIN-rail (DCB01) or Plug-in (PCB01). DCB 01 C M24 Type Selection Mounting Output Housing Supply: 24 VDC and 24 to 240 VAC For DIN-rail 1 x SPDT 2 x SPDT 1 x SPDT 2 x SPDT D-Housing DCB 01 C M24 P-Housing PCB 01 C M24 Plug-in DCB 01 D M24 PCB 01 D M24 Time Specifications Time ranges Selectable by DIP switches Setting accuracy Repeatability Time variation Within rated power supply Within ambient temperature Reset Power supply interruption Supply: 24 to 240 VAC/DC Output Specifications 0.1 to 1 s 1 to 10 s 6 to 60 s 60 to 600 s 0.1 to 1 h 1 to 10 h 10 to 100 h ≤ 5% ≤ 0.2% (with respect to full scale value) ≤ 0.2% - whole range ≤ 500 ppm/°C ≥ 200 ms Specifications are subject to change without notice (15.12.05) Output Rated insulation voltage Contact Ratings (AgSnO2) Resistive Loads AC 1 DC 12 Small inductive loads AC 15 DC 13 Mechanical life Electrical life Operating frequency Dielectric strength Dielectric voltage Rated impulse withstand voltage 1 or 2 x SPDT relay 250 VAC (RMS) µ 8 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC ≥ 30 x 106 operations ≥ 105 operations (at 8 A, 250 V, cos ϕ = 1) < 7200 operations/h 2 kVAC (RMS) 4 kV (1.2/50 µs) 1 DCB01, PCB01 Supply Specifications General Specifications (cont.) Power Supply Rated operational voltage trough terminals: Overvoltage cat. III (IEC 60664, IEC 60038) Environment Degree of protection Pollution degree 24 VDC ± 15 % and 24 to 240 VAC +10% -15% 45 to 65 Hz Operating temperature Storage temperature Housing dimensions DIN-rail version Plug-in version Weight Screw terminals Tightening torque (DCB01C) (PCB01C) A1, A2: 2, 10: (DCB01D) A1, A2: (PCB01D) 2, 10: Voltage interruption Rated operational power 24 to 240 VAC/DC +10% -15%, 45 to 65 Hz ≤ 10 ms 1.5 W General Specifications ≤ 100 ms ≤ 200 ms Power ON delay Power OFF delay Indication for Power supply ON Output relays ON LED, green LED, yellow (flashing when timing) (EN 60529) IP 20 3 (DCB01), 2 (PCB01) (IEC 60664) -20 to +60 °C, R:H: < 95% -30 to +80 °C, R:H: < 95% EMC Immunity Emission Timer Specifications 22.5 x 80 x 99.5 mm 36 x 80 x 94 mm Approx 100 g (DCB01) Max. 0.5 Nm according to IEC EN 60947 Electromagnectic Compatibility According to EN 61000-6-2 According to EN 61000-6-3 According to EN 61812-1 Approval CE Marking UL, CSA Yes Mode of Operation Function Aa - Asymmetrical Recycler ON-time period first The relay operates and the ON-time period (T1) begins as soon as the power supply is connected. After the ONtime period the relay releases for the OFF-time period (T2). This sequence continues until the power supply is interrupted for at least 200 ms. Function Ab - Asymmetrical Recycler OFF-time period first The OFF-time period (T1) begins as soon as the power supply is connected. After the OFF-time period the relay operates for the ONtime period (T2). This sequence continues until the power supply is interrupted for at least 200 ms. Function Sh - One shot time function The OFF-time period (T1) begins as soon as the power supply is connected. After the OFF-time period the relay operates for the ONtime period (T2). After the ON-time period the relay releases and does not operate until the power supply is interrupted for at least 200 ms and connected again. Function Dt - Two state delay on operate (2 x SPDT versions) The first time period (T1) begins as soon as the power supply is connected. At the end of the first time period the first relay operates and the second time period (T2) begins. At the end of the second time period the second relay operates. Both relays release when the power supply is disconnected. Function/Range/Time Setting Upper knob: Setting of function: Aa - asymmetrical recycler (ON first) Ab - asymmetrical recycler (OFF first) Sh - One shot time function Dt - Two-state delay on operate (2 x SPDT versions) Centre knob: Time T1 setting on relative scale: 1 to 10 with respect to the chosen range. Lower knob: Time T2 setting on relative scale: 1 to 10 with respect to the chosen range. 2 Selection of time ranges Adjust the T1 time range setting the DIP-switches 1 to 3 and the T2 time range setting the DIP-switches 4 to 6 as shown on the left. To access the DIP-switches open the plastic cover using a screwdriver as shown below. T1 time range ON ON ON: ON ON OFF: ON OFF ON: ON OFF OFF: OFF ON ON: OFF ON OFF: OFF OFF ON: 0.1 to 1 s 1 to 10 s 6 to 60 s 60 to 600 s 0.1 to 1 h 1 to 10 h 10 to 100 h T2 time range ON ON ON: ON ON OFF: ON OFF ON: ON OFF OFF: OFF ON ON: OFF ON OFF: OFF OFF ON: 0.1 to 1 s 1 to 10 s 6 to 60 s 60 to 600 s 0.1 to 1 h 1 to 10 h 10 to 100 h Specifications are subject to change without notice (15.12.05) DCB01, PCB01 Wiring Diagrams DCB01 PCB01 Operation Diagrams Function Aa - Asymmetrical Recycler - ON first Function Ab - Asymmetrical Recycler - OFF first Power supply Power supply T1 T2 T1 T2 T1 T1 T2 T1 T2 T1 Relay ON ON Relay ONON OFF OFF Red ON LED ON LED LED Red ON LED ON Function Sh - One Shot Function Dt - Two state Delay on operate (2xSPDT only) Power supply Power supply T1 T2 T1 Relay ON ON Relay1 ON ON OFF OFF T2 Relay2 ON ON LED ON ON Red LED OFF Red ON LED ON LED Dimensions DIN-rail Plug-in 94 90 63 28.5 Specifications are subject to change without notice (15.12.05) 80 36 63 99.5 83.5 80 22.5 28.5 3